FOR SERVICE TECHNICIAN’S USE ONLY
Component Testing Chart - Electric MRC Models with AquaLift™ Technology
NOTE:
This Component Testing Chart covers different models. The range may have some or all of the components listed in the following chart.
Do not continue with the diagnosis of the appliance if a fuse is blown, a circuit breaker is tripped, or if there is less than 240+10%/-15% volt power
supply at the wall outlet.
When checking for proper voltage, complete the following steps:
1.
Unplug range or disconnect power.
2.
Connect voltage measurement equipment.
3.
Plug in range or reconnect power and confirm voltage reading.
4.
Unplug range or disconnect power after performing voltage
measurements.
Component
From
To
Resistance: Measure Without
e
g
a
t
l
o
V
l
a
n
i
m
o
N
s
e
t
o
N
d
e
il
p
p
A
r
e
w
o
P
Door position
switch
P7-4
P7-5
Door open = open circuit
Door closed = closed circuit
2 VDC with door open
0 VDC with door closed
Oven light
P5-4
W (Neutral)
P6-3
0 - 40
h
ti
w
e
c
n
a
t
s
i
s
e
r
e
r
u
s
a
e
M
l
a
n
i
m
o
n
oven light switch open and
door closed.
Measure voltage with oven
light switch closed or door
open.
N/A
120 VAC
Thermo fuse
P1-3
P2-4
Closed circuit (normal)
Open circuit if temperatures at the
back of the oven exceed 360°F (184°C)
Thermo fuse will open if it
exceeds temperature.
Measure for a closed
circuit (0 resistance).
N/A
Oven sensor
P10-1
P10-2
1000 - 1200 at room temperature
Disconnect connector P10
from control before
measuring sensor. Measure
only resistance, not
voltage.
N/A
Bake element
P1-4
P3-1/P3-2
10 - 40 nominal. Check both P3-1
and P3-2 terminals - one open circuit
and one closed circuit.
For voltage measurements
in Bake mode, Bake cycle
must be operating.
240 VAC when energized
Broil element
P1-1
P3-1/P2-1
10 - 40 nominal. Check both P3-1
and P3-2 terminals - one open circuit
and one closed circuit.
For voltage measurements
in Broil mode, Broil cycle
must be operating.
240 VAC when energized
Warming drawer
sensor
P10-3
P10-4
1000 - 1200 at room temperature
Disconnect connector P10
from control before
measuring warming drawer
temperature sensor.
N/A
Warming drawer
element
P4-2
W (Neutral)
P6-3
15 - 20 nominal
Measure voltage with
Warm Drawer on.
120 VAC
Convection fan
motor
P5-2
W (Neutral)
P6-3
85 - 90
Convection fan runs in
Convection Bake mode.
120 VAC
Convection
element
P2-3
W (Neutral)
P6-3
16
l
li
w
t
n
e
m
e
l
e
n
o
it
c
e
v
n
o
C
l
a
n
i
m
o
n
cycle on and off.
Convection Bake cycle
must be operating.
120 VAC
Limiter switches
Term
2B or S
Term
1B or H
Normally open switch closes at
150°F (65.6°C) to turn on hot surface
indicator light.
Normal = Infinite
resistance
Term
Single - 1A’,
Dual - 4/4A
or 3/1,
Triple - P1
Term
2A or 2
Normally closed switch opens at
1050°F (566°C).
Normal = 0 resistance