Maytag YMER8800FZ Tech  Manual Download Page 1

FOR SERVICE TECHNICIAN’S USE ONLY

Temperature Adjustment (All MRC Controls)

NOTE:

 On models with a numeric keypad on the control, press the “3” key instead of the “up” arrow or “+” (plus) keypad. Press the “6” key instead of 

the “down” arrow or “-” (minus) keypad. On some models, press the OFF keypad if there is not a CANCEL keypad.

W11401670A

FOR SERVICE TECHNICIAN’S USE ONLY

DANGER

Electrical Shock Hazard

Only authorized technicians should perform diagnostic 

voltage measurements.
After performing voltage measurements, disconnect 

power before servicing.
Failure to follow these instructions can result in death 

or electrical shock.

WARNING

Electrical Shock Hazard

Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.

s

e

t

o

N

d

e

s

s

e

r

P

 

d

a

p

y

e

K

n

o

i

t

c

n

u

F

p

e

t

S

1

Temperature adjustment

Press OVEN LIGHT for 5 seconds

The current offset is shown in the display, or 0° if there  

is no offset.

2

Temperature adjustment options

(Depending on model)
Temp/Time or Temp/Hour 

Press “MORE” or “LESS” arrow keys

                            or
Press “+” (plus) or “-” (minus) keypads

Adjust temperature in 5°F (3°C) increments. The range 

can be set between 30°F (18°C) and -30°F (-18°C).
Bake temperature adjustment cannot result in 

operating temperatures higher than 550°F (288°C) or 

lower than 170°F (77°C), as measured at the oven 

center.
The broil temperature is automatically offset the same 

as the bake temperature.

3

 

d

e

ri

s

e

D

T

R

A

T

S

 

s

s

e

r

P

t

n

e

m

t

s

u

j

d

a

 

e

r

u

t

a

r

e

p

m

e

t

 

e

t

a

v

it

c

A

temperature adjustment is activated. If “Start” 

is not pressed within 1 minute, adjustment is ignored.

Voltage Measurement Safety Information

When performing live voltage measurements, you must do the following:

Verify the controls are in the off position so that the appliance does not start when energized.
Allow enough space to perform the voltage measurements without obstructions.
Keep other people a safe distance away from the appliance to prevent potential injury.
Always use the proper testing equipment.
After voltage measurements, always disconnect power before servicing.

Tech Manual

 

 

Summary of Contents for YMER8800FZ

Page 1: ... is no offset 2 Temperature adjustment options Depending on model Temp Time or Temp Hour Press MORE or LESS arrow keys or Press plus or minus keypads Adjust temperature in 5 F 3 C increments The range can be set between 30 F 18 C and 30 F 18 C Bake temperature adjustment cannot result in operating temperatures higher than 550 F 288 C or lower than 170 F 77 C as measured at the oven center The broi...

Page 2: ...trol for example 0 Failures and 2 Faults found Control is good There is a problem with a wiring harness wiring connection or component outside the control 4 Press CANCEL to exit Refer to the Failure Error Display Codes section to correct Step Service Mode Service Mode Description Upon entry TEST ON Perform relay checks See the Relay Checks for MRC Control section Press the key that is listed in th...

Page 3: ...Replace all parts and panels before operating 5 Plug in range or reconnect power 6 Verify operation is normal Go to the Diagnostics Mode and scroll to the Faults display to clear faults F2 E0 E1 E2 Keypad disconnected Stuck key Cancel key error F3 E0 Main sensor open or shorted 1 Press CANCEL CANCEL START to enter the Diagnostics Mode At the first screen verify the main oven sensor temperature rea...

Page 4: ...or switch 6 If there is damage to wires or connectors replace the harness If there is no damage to wires or connectors replace the door switch 7 Replace all parts and panels before operating 8 Plug in range or reconnect power 9 Press CANCEL OFF key Select and start the SELF CLEAN or PRECISE CLEAN function Observe for at least 1 minute to ensure that operation is normal 10 Go to the Diagnostics Mod...

Page 5: ...ill open if it exceeds temperature Measure for a closed circuit 0 resistance N A Oven sensor P10 1 P10 2 1000 1200 at room temperature Disconnect connector P10 from control before measuring sensor Measure only resistance not voltage N A Bake element P1 4 P3 1 P3 2 10 40 nominal Check both P3 1 and P3 2 terminals one open circuit and one closed circuit For voltage measurements in Bake mode Bake cyc...

Page 6: ...center element Convection fan Oven light L1 input Conn P6 Red P7 Black P10 Yellow Pin 1 3 4 5 1 2 3 4 Function Control L1 input Control neutral Door switch common Door position switch Oven temp sensor Oven temp sensor Warm drawer temp sensor Warm drawer temp sensor 3 and 4 on some models P1 Blue P2 Red P7 Black P10 Yellow P3 White P5 Blue P6 Red BK BK W V V BK R Y Y GY OR BU R W R BK Y P4 Green OR...

Page 7: ...FOR SERVICE TECHNICIAN S USE ONLY ...

Page 8: ... information please see Pat www patent listing com W11401670A NOTE This sheet contains important Technical Service Data FOR SERVICE TECHNICIAN ONLY DO NOT REMOVE OR DESTROY W11401670A 20 All rights reserved FOR SERVICE TECHNICIAN S USE ONLY 02 20 ...

Page 9: ...t affichée 2 Options de réglage de la température Selon le modèle Temp Time temp durée ou Temp Hour temp heure Appuyer sur les touches à flèche MORE plus ou LESS moins ou Appuyer sur les touches plus ou moins Régler la température par tranches de 5 F 3 C La plage de décalage possible est comprise entre 30 F 18 C et 30 F 18 C Le réglage de la température de cuisson au four ne peut pas donner lieu à...

Page 10: ... CANCEL annulation pour quitter Voir la section Codes d anomalie erreur présentés sur l afficheur pour résoudre les erreurs Étape Mode de dépannage Description du mode de dépannage Dès l entrée dans le mode TEST ON test activé Contrôle les relais Voir la section Contrôle des relais du module de commande MRC Appuyer sur la touche indiquée dans la colonne Touche à utiliser correspondant à la fonctio...

Page 11: ... jusqu à l affichage Faults anomalies pour effacer les anomalies F2 E0 E1 E2 Clavier déconnecté Touche coincée Touche d annulation Cancel erreur F3 E0 Capteur principal ouvert ou court circuité 1 Appuyer sur CANCEL CANCEL START annulation annulation mise en marche pour accéder au mode de diagnostic À partir du premier écran contrôler la température donnée par le capteur du four principal Le cas éc...

Page 12: ...er le faisceau de câblage Si les conducteurs ou les connecteurs ne sont pas endommagés remplacer le contacteur de la porte 7 Replacer pièces et panneaux avant de faire la remise en marche 8 Brancher la cuisinière ou reconnecter la source de courant électrique 9 Appuyer sur la touche CANCEL OFF annulation arrêt sélectionner la fonction SELF CLEAN autonettoyage ou PRECISE CLEAN nettoyage de précisio...

Page 13: ... fermé résistance nulle N A Capteur du four P10 1 P10 2 1000 1200 à température ambiante Déconnecter le connecteur P10 du module de commande avant de mesurer le capteur thermométrique du four Mesurer uniquement la résistance et non pas la tension N A Élément de cuisson au four P1 4 P3 1 P3 2 10 40 nominal Vérifier les deux bornes P3 1 et P3 2 un circuit ouvert et un circuit fermé Pour les mesures ...

Page 14: ...e P7 Noir P10 Jaune Broche 1 3 4 5 1 2 3 4 Fonction Entrée L1 module de commande Neutre du module de commande Contacteur porte broche commune Contacteur de position de la porte Capteur thermométrique du four Capteur thermométrique du four Capteur de température du tiroir réchaud Capteur de température du tiroir réchaud 3 et 4 sur certains modèles P1 Bleu P2 Rouge P7 Noir P10 Jaune P3 Blanc P5 Bleu...

Page 15: ...À L USAGE DU TECHNICIEN DE RÉPARATION UNIQUEMENT Remarques 15 ...

Page 16: ...patent information please see Pat www patent listing com W11401670A NOTE This sheet contains important Technical Service Data FOR SERVICE TECHNICIAN ONLY DO NOT REMOVE OR DESTROY W11401670A 2020 All rights reserved FOR SERVICE TECHNICIAN S USE ONLY 02 20 ...

Reviews: