Connect ground wire (green or bare) of power supply cable to external ground conductor
screw. Tighten screw.
4.
Place the hooked ends of the other power supply cable wires under the outer terminal
block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
5.
Tighten strain relief screws.
6.
Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-
down screw.
7.
You have completed your electrical connections. Now go to “Venting Requirements.”
3-wire connection: Power Supply Cord
Use where local codes permit connecting cabinet-ground conductor to neutral wire:
1.
Loosen or remove center silver-colored terminal block screw.
2.
Connect neutral wire (white or center wire) of power supply cord to the center, silver-
colored terminal screw of the terminal block. Tighten screw.
3.
Connect the other wires to outer terminal block screws. Tighten screws.
4.
Tighten strain relief screws.
5.
Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-
down screw.
6.
You have completed your electrical connections. Now go to “Venting Requirements.”
A. External ground conductor screw
B. Center silver-colored terminal block screw
C. Neutral wire (white or center wire)
D. ¾" (1.9 cm) UL listed strain relief
E. Ground wire (green or bare) of power supply cable
F. Neutral ground wire
E
D
A
B
C
F
A. 3-wire receptacle (NEMA type 10-30R)
B. 3-wire plug
C. Neutral prong
D. Spade terminals with up turned ends
E.
³⁄₄
" (1.9 cm) UL listed strain relief
F. Ring terminals
G. Neutral (white or center wire)
A. Neutral ground wire
B. External ground conductor screw
C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire)
E.
³⁄₄
" (1.9 cm) UL listed strain relief
A
B
D
C
E
F
G
A
B
C
D
E