Maytag sav2655aw Technical Information Download Page 10

Wiring Diagram and Schematic

 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing, unless 
testing requires it. 
 

16022616   Rev. 0 

October 2003 

10

VLT

PNK

WHT

GRN/YLW

VLT

BLU

 
 

Motor Connector 

Timer Connector 

C

O

N

N

E

C

T

IO

N

 D

IA

G

R

A

M

R

ID

G

E

 O

R

 T

IN

N

E

D

 T

E

R

M

IN

A

L

 =

 N

E

U

T

R

A

L

8

8

1

1

4

6

4

6

7

3

G

R

N

/Y

E

L

5

7

3

5

W

H

T

/R

E

D

M

IX

IN

G

 V

A

L

V

E

C

O

L

D

G

R

N

/Y

E

L

H

O

T

C

A

B

IN

E

T

G

R

O

U

N

D

 T

O

C

O

R

D

P

O

W

E

R

F

A

G

K

M

E

D

G

R

O

U

N

D

 T

O

T

O

P

B

L

K

1

8

 G

A

.

W

H

T

G

R

N

V

L

T

1

1

5

1

4

B

R

N

C

O

N

N

E

C

T

O

R

B

L

U

1

0

1

6

P

N

K

E

X

C

B

E

X

T

R

A

 R

IN

S

E

B

L

U

/W

H

T

6

3

1

S

W

IT

C

H

C

O

M

.

T

M

T

M

L

P

S

B

P

P

N

K

/B

L

U

W

H

T

/B

L

K

1

7

N

.O

.

L

ID

 S

W

IT

C

H

1

2

G

R

Y

/B

L

K

7

P

N

K

/B

L

U

4

T

IM

E

R

T

O

 T

O

P

G

R

O

U

N

D

2

4

 P

IN

T

E

M

P

S

W

IT

C

H

4

 P

O

S

IT

IO

N

W

H

T

/R

E

D

R

E

D

/B

L

K

2

4

2

2

2

3

L

2

O

R

G

G

R

Y

1

L

1

2

G

R

Y

H

V

P

2

B

P

2

Y

LW

/B

L

K

9

P

S

1

X

B

1

5

L

9

9

M

O

T

O

R

 S

W

IT

C

H

R

E

D

/B

L

K

B

L

K

/P

N

K

8

A

1

3

K

1

8

H

I

O

R

G

2

3

1

S

W

IT

C

H

P

R

E

S

S

U

R

E

Summary of Contents for sav2655aw

Page 1: ...l RS3100007 for detailed installation operating testing troubleshooting and disassembly instructions CAUTION All safety information must be followed as provided in this Technical Sheet and in Service...

Page 2: ...h for continuity between terminals See component testing Check timer contacts Check for continuity on water valve solenoid See component testing Vibration Weak floors can cause vibration and walking L...

Page 3: ...y need to be purged prior to starting wash cycle Disconnect inlet hoses and clean screens Will Not Spin Check for unbalanced load Does the house drain system accept water from machine Check for blocke...

Page 4: ...old Side 2 25 gpm Hot Side 2 00 gpm Mix 3 00 gpm at 30 120 psi Measure resistance of terminals on each valve Resistance across each valve 1000 10 Drain Pump Verify Drain Pump is not clogged or damaged...

Page 5: ...Rinse Switch Disconnect wires from component to properly measure the resistance Place switch in the following positions and measure across the terminals below On YL YL Off Continuity 1 Infinite Temper...

Page 6: ...washer before servicing unless testing requires it 16022616 Rev 0 October 2003 6 4 POLE MAIN Y E L L O W 6 POLE MAIN BLUE VIOLET RED B R O W N AUX WHITE PROTECTOR WHITE Y BU BR W P R G RUN START WIRI...

Page 7: ...n switch terminal P and Violet wire Manually depress actuator Continuity exists between switch terminal P and Violet wire Inoperative low speed switch Replace switch Motor switch checks OK NO YES YES...

Page 8: ...Pause 0 00 21 Spin medium 0 02 42 Spin Spray warm or cold medium 0 00 21 Spin medium 0 02 36 Pause 0 00 21 Rinse Fill Agitate warm or cold fast 0 02 39 Pause 0 00 21 Spin fast 0 08 39 0 29 21 OFF PAU...

Page 9: ...23 4 75 d 132 25 d 24 5 00 d 137 25 d 25 4 75 d 142 00 d 26 5 75 d 147 75 d 27 5 75 d 153 50 d 28 4 75 d 158 25 d 29 7 50 d 165 75 d 3 0 7 50 d 173 25 d 31 7 50 d 180 75 d 32 7 50 d 188 25 d 3 3 4 75...

Page 10: ...8 8 1 1 4 6 4 6 7 3 GRN YEL 5 7 3 5 WHT RED MIXING VALVE COLD GRN YEL HOT CABINET GROUND TO CORD POWER F A G K MED GROUND TO TOP BLK 18 GA WHT GRN VLT 11 5 14 BRN CONNECTOR BLU 10 16 PNK EX CB EXTRA...

Page 11: ...1 TIMER BUSS INDICATES INTERNAL 120 VOLTS A C 60 HZ LID SWITCH N O EX A PS PRESSURE 11 A PS N EXTRA RINSE SW H O T MIXING VALVE C O L D 12 14 HI MED 2 SPEED MOTOR F L G L K TM MOTOR TIMER BP BP 2 1 K...

Reviews: