Maytag MLG34 Installation & Operator'S Manual Download Page 3

113497 - 1

Maytag Co.

3

IMPORTANT

You must disconnect and lockout the electric
supply and the gas supply before any covers or
guards are removed from the machine to allow
access for cleaning, adjusting, installation, or
testing of any equipment per OSHA standards.

Please observe all safety precautions displayed
on the equipment and/or specified in the installation
manual included with the dryer.

Before installation, check that the local distribution
conditions, nature of gas and pressure, and
adjustment of the appliances are compatible.

CAUTION

Dryer(s) should never be left unattended while in
operation.

“Caution: Label all wires prior to disconnection
when servicing controls.  Wiring errors can cause
improper operation.”

«Attention: Au moment de l’entretien des
commandes, étiquetez tous les fils avant de les
débrancher.  Des erreurs de câblage peuvent
entraîner un fonctionnement inadéquat et
dangereux.»

WARNING

Children should not be allowed to play on or near
the dryer(s).  Children should be supervised if near
dryer(s) in operation.

Under no circumstances should the dryer door
switch(es), lint door/drawer switch(es), or heat
safety circuit(s) ever be disabled.

The dryer must never be operated with any of the
back guards, outer tops, or service panels
removed.  Personal injury or fire could result.

The dryer must never be operated without the lint
filter/screen in place, even if an external lint
collection system is used.

If a hi-limit switch trips, a service call is required to
investigate the reason and resolve the issue.

FOR YOUR SAFETY

Do not dry mop heads in the dryer.  Do not use
dryer in the presence of dry cleaning fumes.

The dryers must not be installed or stored in an
area where it will be exposed to water and/or
weather.

The wiring diagram for the dryer is located behind
the control panel.

Table of Contents _____________________

List of Acronyms _____________________

HVAC

Heating, Ventilating, and Air-Conditioning

in WC

Inches of Water Column

L.C.D.

Liquid Crystal Display

L.P.

Liquid Propane

OSHA

Occupational Safety and Health Administration

UL

Underwriters Laboratory

State of California Proposition 65 Warnings:

WARNING: 

This product contains a chemical

known to the State of California to cause cancer.

WARNING: 

This product contains a chemical

known to the State of California to cause birth
defects or other reproductive harm.

In the State of Massachusetts, the following
installation instructions apply:

Installations and repairs must be performed
by a qualified or licensed contractor,
plumber, or gasfitter qualified or licensed by
the State of Massachusetts.

If using a ball valve, it shall be a T-handle
type.

A flexible gas connector, when used, must
not exceed 3 feet.

Safety Precautions ..................................... 4
Specifications ............................................. 6
Installation Procedures .............................. 8

Location Requirements ................................................. 8

Unpacking/Setting Up .................................................... 8

Dryer Enclosure Requirements ..................................... 8

Fresh Air Supply Requirements .................................... 9

Exhaust Requirements .................................................. 9

Electrical Information ................................................... 11

Gas Information ........................................................... 12

Converting from One Family of Gas to Another .......... 15

Gas Pressure Testing .................................................. 17

Preparation for Operation/Start-Up ............................. 17

Preoperational Test ...................................................... 18

Preoperational Instructions ......................................... 18

Shutdown Instructions ................................................. 18

Service/Parts Information ........................ 18

Service ......................................................................... 18

Parts ............................................................................. 18

Warranty Information ............................... 19

Warranty ...................................................................... 19

Routine Maintenance................................ 19

Cleaning ....................................................................... 19

Adjustments ................................................................. 19

Data Label Information............................. 20

Summary of Contents for MLG34

Page 1: ...upplier AVERTISSEMENT Assurez vous de bien suivre les instructions donn es dans cette notice pour r duire au minimum le risque d incendie ou d explosion ou pour viter tout dommage mat riel toute bless...

Page 2: ...___ SERIAL NUMBER S __________________________________________________________________________________ _________________________________________________________________________________________________...

Page 3: ...t dry mop heads in the dryer Do not use dryer in the presence of dry cleaning fumes The dryers must not be installed or stored in an area where it will be exposed to water and or weather The wiring di...

Page 4: ...m sponge rubber or similarly textured rubber materials Drying in a heated tumbler may damage plastics or rubber and also may be a fire hazard A program should be established for the inspection and cle...

Page 5: ...______________________________________ ____________________________________________________________ NOTES _____________________________________________________ ________________________________________...

Page 6: ...R CONNECTION N A COMPRESSED AIR VOLUME N A INLET PIPE CONNECTION PER POCKET 1 2 M N P T 3 8 M B S P T CE ONLY VOLTAGE AVAILABLE N A APPROXIMATE NET WEIGHT APPROXIMATE SHIPPING WEIGHT AIRFLOW PER POCKE...

Page 7: ...113497 1 Maytag Co 7 Specifications _______________________________________________________________________...

Page 8: ...necessary The dryer must be installed with adequate clearance for air openings into the combustion chamber CAUTION This dryer produces combustible lint and must be exhausted to the outdoors Every 6 mo...

Page 9: ...use of 90 turns be avoided use 30 and or 45 bends instead The radius of the elbows should preferably be 1 1 2 times the diameter of the duct All ductwork should be smooth inside with no projections fr...

Page 10: ...uns the cross sectional area of the ductwork can only be increased to an extent When the ductwork approaches the maximum limits as noted in this manual a professional HVAC firm should be consulted for...

Page 11: ...164 120 80 54 SQ CM 1058 774 2 516 1 348 4 MINIMUM ROUND DUCT DIAMETER IN 14 12 10 8 CM 35 56 30 48 25 4 20 32 Each pocket should be connected to an independently protected branch circuit The dryer mu...

Page 12: ...e ONLY For others calculate verify correct breaker size according to appliance amp draw rating and type of breaker used SERVICE VOLTAGE PHASE WIRE SERVICE APPROX AMP DRAW CIRCUIT BREAKER 60 Hz 50 Hz 1...

Page 13: ...____________________________________________________________ ____________________________________________________________ WARNING Fire or explosion could result due to failure of isolating or disconne...

Page 14: ...nternal regulator disabled Information is per pocket tumbler Consult factory for elevations over 2 000 feet 610 meters for correct orifice size Heat Input Gas Consumption Orifice Injector Data For CE...

Page 15: ...t all connections for leaks by brushing on a soapy water solution liquid detergent works well WARNING Never test for leaks with a flame Converting from One Family of Gas to Another ___________________...

Page 16: ...the dryer and test for leaks IMPORTANT Never test for leaks with an open flame Use a soapy water solution or product intended for that purpose Regulated Gas Valve Refer to Gas Pressure Adjustment on...

Page 17: ...e and the manometer The use of the spring mechanical type gauge is not recommended because they are very easily damaged and are not always accurate The preferred type of gauge is the manometer because...

Page 18: ..._ IMPORTANT For more detailed information regarding the microprocessor controller computer refer to the microprocessor user s manual included with the dryer Coin Models Microprocessor Controller Compu...

Page 19: ...quency of cleaning the lint screen can best be determined from experience at each location Weekly Clean lint accumulation from lint chamber thermostat and microprocessor temperature sensor area WARNIN...

Page 20: ...2 Serial Number Allows the manufacturer to gather information on your particular dryer 3 Type of Heat This describes the type of heat for your particular dryer gas either natural gas or L P gas elect...

Page 21: ..._____________________________________________ _________________________________________________________________________________________________________________________________ ________________________...

Page 22: ...Part No 113497 1 12 10 10 0...

Reviews: