background image

4

Maytag Co.

113062 - 17

Important Information ________________

IMPORTANT:

 A means of restraint must be used to prevent

straining of the gas supply when the dryer is moved.
An external means of power removal (disconnect device)
must be provided by the installer.

List of Acronyms _______________________

AWG

American Wire Gauge

DSI

Direct Spark Ignition

HVAC

Heating, Ventilating, and Air-Conditioning

in wc

Inches of Water Column

L.E.D.

Light Emitting Diode

L.P.

Liquid Propane

OSHA

Occupational Safety And Health Administration

UL

Underwriters Laboratory

“Caution: Label all wires prior to
disconnection when servicing controls.
Wiring errors can cause improper
operation.”
«Attention: Au moment de l’entretien des
commandes, étiquetez tous les fils avant de
les débrancher.  Des erreurs de câblage
peuvent entraîner un fonctionnement
inadéquat et dangereux.»

WARNING

The dryer must never be operated with any
of the back guards or service panels
removed.  Personal injury or fire could result.
The wiring diagram for the dryer is located
behind the front control panel on the right
side.

Table of Contents ________

Important Information ............................................... 5

Receiving and Handling ........................................... 5
Safety Precautions ................................................. 5

Specifications ............................................................ 7

Installation Procedures ............................................. 8

Unpacking/Setting Up ............................................. 8
Location of the Dryer ............................................... 8
Dryer Enclosure Requirements ............................... 9
Fresh Air Supply Requirements .............................. 9
Exhaust Requirements ........................................... 9
Electrical Information ............................................. 11
Gas Information .................................................... 12
Preparation for Operation ...................................... 14
Preoperational Test ............................................... 14
Shutdown Instructions .......................................... 15

Operating Instructions ............................................. 15

Starting the Dryer .................................................. 15

Service/Parts Information ...................................... 15

Service .................................................................. 15
Parts ..................................................................... 15

Warranty Information .............................................. 15

Returning Warranty Cards..................................... 15
Warranty ............................................................... 15

Routine Maintenance .............................................. 16

Cleaning ............................................................... 16
Adjustments ......................................................... 16
Lubrication ............................................................ 16

Dryer Data Label Information ................................ 17

Data Label Location .............................................. 17
Data Label ............................................................ 17

Summary of Contents for MLG32PDB

Page 1: ...MLG32PDB Installation Manual 30 lb Stacked Model Part No 113062 17 RETAIN THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE ...

Page 2: ...ny appliance Do not touch any electrical switch Do not use any phone in your building Clear the room building or area of all occupants Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier A...

Page 3: ...oam rubber or similarly textured rubber like materials Clean lint screen every third load to fourth Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint dust and dirt The interior of the dryer and exhaust vent should be cleaned periodically by qualified service personnel See installation instructions for grounding requirements IMPORTANT The gas ins...

Page 4: ...age peuvent entraîner un fonctionnement inadéquat et dangereux WARNING The dryer must never be operated with any of the back guards or service panels removed Personal injury or fire could result The wiring diagram for the dryer is located behind the front control panel on the right side Table of Contents ________ Important Information 5 Receiving and Handling 5 Safety Precautions 5 Specifications ...

Page 5: ...he dryer must never be operated with any of the back guards outer tops or service panels removed Personal injury or fire could result WARNING What To Do If You Smell Gas Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Clear the room building or area of all occupants Immediately call your gas supplier from a neighbor s phone Follow the gas ...

Page 6: ... any covers or guards are removed from the machine to allow access for cleaning adjusting installation or testing of any equipment per OSHA standards WARNING IMPORTANT Dryer must be installed in a location environment which the ambient temperature remains between 40 F 4 44 C and 130 F 54 44 C Notes _______________________________________________________ ____________________________________________...

Page 7: ...BASKET TUMBLER MOTOR 2 PLACES 1 2 HP DOOR OPENING DIAMETER 2 PLACES 21 1 2 AIRFLOW PER BASKET TUMBLER 420 cfm HEAT INPUT TOTAL FOR BOTH BASKETS TUMBLERS 160 000 btu hr GAS INLET SIZE 3 4 EXHAUST DUCT OUTLET 8 APPROXIMATE WEIGHT UNCRATED 850 lbs APPROXIMATE WEIGHT CRATED 880 lbs ELECTRIC REQUIREMENTS PER BASKET TUMBLER 120 Volt 1 Phase 9 amp 5 3 01 NOTE Manufacturer reserves the right to make chang...

Page 8: ...an Electrical Codes Parts 1 2 CSA C22 1 1990 or LATEST EDITION for Electrical Connections Unpacking Setting Up _________________ Remove protective shipping material i e plastic wrap and optional shipping box from dryer NOTE The access keys for the service doors are included in the information packet shipped in the tumbler These keys should be removed and put in a safe place yet made accessible bec...

Page 9: ...ustible materials and must be located a minimum of 12 inches 18 inches or more is recommended for ease of installation maintenance and service above the dryer outer top except along the front of the dryer which may be closed in if desired NOTE Even though a minimum of 12 inches above the dryer outer top is acceptable a clearance of 18 inches or more is suggested for ease of installation and servic...

Page 10: ... exhaust duct increaser transition piece is available from the factory by ordering Part No 882099 Multiple Dryer Common Venting If it is not feasible to provide separate exhaust ducts for each dryer ducts from individual dryers may be channeled into a common main duct The individual ducts should enter the bottom or side of the main duct at an angle not more than 45 in the direction of the airflow ...

Page 11: ...t conform to applicable requirements of the National Electrical Code ANSI NFPA NO 70 LATEST EDITION or in Canada the installation must conform to applicable Canada Standards Canadian Electrical Codes Parts 1 2 CSA C22 1 1990 or LATEST EDITION The ground connection may be to a proven earth ground at the location service panel For added personal safety when possible it is suggested that a separate g...

Page 12: ...xcess of 1 2 psig 3 5 kPa The dryer must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply system at test pressures equal to or less than 1 2 psig 3 5 kPa IMPORTANT Failure to isolate or disconnect the dryer from supply as noted can cause irreparable damage to the gas valve voiding the warranty Fire Hazard Fir...

Page 13: ...d that a gas shutoff valve be provided to the gas supply line of each dryer for ease of servicing The size of the main gas supply line header will vary depending on the distance this line travels from the gas meter or in the case of L P gas the supply tank the number of tees other gas operated appliances on the supply line etc Specific information regarding supply line size should be determined by...

Page 14: ...ric setting Open main door to stop the dryer and change to a different fabric setting Repeat this procedure until all fabric selections have been tested This will also confirm that setting key circuits and door switch circuits are functioning properly Repeat above procedure for the other tumbler Heat Circuit Operational Test When a gas dryer is first started during initial start up it has a tenden...

Page 15: ...erial number available so that your inquiry can be handled in an expeditious manner Computer Programs and Selections Each microprocessor controller computer has been preprogrammed by the factory with the most commonly used program parameter selections If microprocessor controller computer program changes are required refer to the computer programming manual which was shipped with the dryer Shutdow...

Page 16: ...r vacuum cleaner attachment Remove any lint accumulation from the coin acceptor area including the optical switch Inspect and remove lint accumulation in customer furnished exhaust ductwork system and from the dryer s internal exhaust ducting Inspect and remove lint accumulation from the dryer s exhaust ductwork back draft dampers NOTE A back draft damper that is sticking partially closed can resu...

Page 17: ... It also includes all the necessary data for technical support and parts information When contacting the Maytag Co please have the model and serial numbers available This information is necessary to ensure proper service and parts information from the manufacturer Notes _______________________________________________________ _____________________________________________________________ ___________...

Reviews: