TOOLS AND PARTS

Gather the required tools and parts before starting installation.

Read and follow the instructions provided with any tools listed 

here.

Tools needed for all installations:

 Level

#2 Phillips screwdriver

Wire stripper (direct wire 

installations)

Parts supplied (all models): 

Flat-blade screwdriver

Adjustable wrench that 

opens to 1" (25 mm)  or

hex-head socket wrench 

Tin snips (new vent 

installations)

Caulking gun and compound 

(for installing new exhaust vent)

Vent clamps

1/4" ( 6 mm) nut driver 

(recommended)

Tools needed for gas installations:

8" (203 mm) or 10"  

(254 mm) pipe wrench

8" (203 mm) or 10"  

(254 mm) adjustable wrench  

(for gas connections)

Pipe-joint compound  

resistant to propane gas

Plastic putty knife

INSTALLATION REQUIREMENTS

Leveling legs (4)

Tape measure

Pliers

Parts needed (steam models): 

“Y” connector

Short inlet hose

Inlet hose

Rubber washer (4)

Parts package is located in dryer drum. Check that all parts  

are included.

If using a power supply cord:

Use a UL Listed power supply cord kit marked for use with  

clothes dryers. The kit should contain:

 

A UL Listed 30-amp power supply cord, rated 120/240 

volt minimum, with a temperature rating of 140°F (60°C) 

minimum. The cord should be type SRD or SRDT and be  

at least 4 ft. (1.22 m) long. The wires that connect to  

the dryer must end in ring terminals or spade terminals  

with upturned ends.

 

A UL Listed strain relief.

Summary of Contents for MGDB835DW4

Page 1: ...Requirements 8 Gas Type 8 Gas Supply Line 8 Gas Supply Connection Requirements 9 Burner Input Requirements 9 Dryer Gas Pipe 9 INSTALL LEVELING LEGS 9 MAKE ELECTRICAL CONNECTION U S A ONLY 10 Electrica...

Page 2: ...2 DRYER SAFETY...

Page 3: ...r Clear the room building or area of all occupants IMPORTANT The gas installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or...

Page 4: ...8 203 mm or 10 254 mm adjustable wrench for gas connections Pipe joint compound resistant to propane gas Plastic putty knife INSTALLATION REQUIREMENTS Leveling legs 4 Tape measure Pliers Parts needed...

Page 5: ...RTANT Do not operate install or store dryer where it will be exposed to water weather or at temperatures below 45 F 7 C Lower temperatures may cause dryer not to shut off at end of automatic sensor cy...

Page 6: ...fied electrician determine that the ground path is adequate If using a power supply cord Use a UL Listed power supply cord kit marked for use with clothes dryers The kit should contain A UL Listed 30...

Page 7: ...a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances WARNING Improper connection of the equipm...

Page 8: ...nd gas supplier permit If you are using Natural gas do not use copper tubing WARNING Explosion Hazard Use a new CSA International approved gas supply line Install a shut off valve Securely tighten all...

Page 9: ...f propane gas must be used Do not use TEFLON tape Must include shut off valve In the U S A An individual manual shut off valve must be installed within six 6 ft 1 8 m of the dryer in accordance with t...

Page 10: ...rd or a direct wire connection 2 Remove terminal block cover Remove hold down screw and terminal block cover Put power supply cord through the strain relief Be sure that the wire insulation on the pow...

Page 11: ...minal block screw B Remove neutral ground wire E from external ground conductor screw A B A E Prepare to connect neutral ground wire and neutral wire 1 B E C Connect neutral ground wire and neutral wi...

Page 12: ...lly reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements 2 Connect neutral wire Connect neutral wire white or center C of...

Page 13: ...2 38 mm from remaining 3 wires Strip insulation back 1 25 mm Shape ends of wires into hooks 1 25 mm 5 127 mm 1 Prepare your 4 wire cable for direct connection B E C 3 Connect neutral ground wire and n...

Page 14: ...moved if needed Strip 31 2 89 mm of outer covering from end of cable Strip insulation back 1 25 mm If using 3 wire cable with ground wire cut bare wire even with outer covering Shape wire ends into ho...

Page 15: ...neutral wire 2 Connect neutral ground wire E and neutral wire white or center wire C of power supply cord or cable under center terminal block screw B Tighten screw Connect remaining wires 3 Connect r...

Page 16: ...d make sure exhaust hood is not plugged with lint Replace plastic or metal foil vents with rigid metal or flexible metal vents Review Vent System Chart and if necessary modify existing vent system to...

Page 17: ...from ground or any object that may obstruct exhaust such as flowers rocks bushes or snow Acceptable Style Optional exhaust installations PLAN VENT SYSTEM Recommended exhaust installations Typical ins...

Page 18: ...st systems longer than those specified will Shorten life of dryer Reduce performance resulting in longer drying times and increased energy usage Vent System Chart Number of 90 elbows Type of vent Angl...

Page 19: ...r cold inlet hose to other side of Y connector Screw on coupling by hand until it is seated on connector Using pliers tighten the couplings an additional two thirds turn NOTE Do not overtighten Damage...

Page 20: ...evel Dryer 1 Adjust leveling legs 2 If dryer is not level prop up using a wood block Use wrench to adjust legs up or down and check again for levelness Place level here Place level here CONNECT VENT 1...

Page 21: ...f scale through the water system in the dryer Over time the buildup of lime scale may clog different parts of the water system which will reduce product performance Excessive scale buildup may lead to...

Page 22: ...surface with the inside of the door facing up 5 Install 2 plastic plugs A into screw holes where the hinges were removed in Step 4 Reverse the strike 1 Remove the door strike A from the dryer door ope...

Page 23: ...Remove the 10 screws from the dryer door and set screws off to the side 3 Remove the inner door by using a plastic putty knife to separate the sides and bottom of the dryer door and trim There are 2...

Page 24: ...right side of the door 6 Remove the door hinges and set off to the side 8 Lift door up and rotate trim pieces to the opposite side from which they were removed Then screw trim pieces back in 5 Remove...

Page 25: ...ce with the hinges lined up with the hinge holes 11 Install 6 hinge screws and the other 4 screws 12 Install hinge covers and plugs Hinge covers will go in sideways to then rotate 90 and snap into pla...

Page 26: ...2017 All rights reserved Tous droits r serv s W11101355A W11101358A SP 03 17...

Reviews: