Mobile home - Additional installation requirements: 

This dryer is suitable for mobile home installations.  

The installation must conform to the Manufactured  

Home Construction and Safety Standard, Title 24 CFR,  

Part 3280 (formerly the Federal Standard for Mobile home 

construction and Safety, Title 24, HUD Part 280) or Standard 

CAN/CSA-Z240 MH.

Mobile home installations require: 

All dryers:

 

Metal exhaust system hardware, available for purchase  

from your dealer. For further information, see “Assistance  

or Service” section in your “Use and Care Guide.”

 

Special provisions must be made in mobile homes to  

introduce outside air into dryer. Openings (such as a  

nearby window) should be at least twice as large as  

dryer exhaust opening.

For gas dryers mobile home installations:

 

Mobile Home Installation Hold-down Kit Part Number 

W10432680 is available to order. For further information,  

see “Assistance or Service” section in your “Use and  

Care Guide.”

6"/0"

(152 mm/

0 mm)

14" max

(356 mm)

1"/0"

(25 mm/0 mm)

18"/18"

(457 mm/

457 mm)

3"/3"

(76 mm/

76 mm)

48"

2/

48"

2

(310 cm

2/

310 cm

2

)

24"

2/

24"

2

(155 cm

2/

155 cm

2

)

3"/3"

(76 mm/

76 mm)

1"/1"

(25 mm/25 mm)

Recommended/Minimum spacing 

ELECTRICAL REQUIREMENTS -  

U.S.A. ONLY (SPÉCIFICATIONS 

ÉLECTRIQUES – ÉTATS-UNIS 

SEULEMENT)

It is your responsibility:

 

To contact a qualified electrical installer.

 

To be sure that the electrical connection is adequate and in 

conformance with the National Electrical Code, ANSI/NFPA 

70 - latest edition and all local codes and ordinances. 

 

The National Electrical Code requires a 4-wire power supply 

connection for homes built after 1996, dryer circuits involved 

in remodeling after 1996, and all mobile home installations. 

 

A copy of the above code standards can be obtained from: 

National Fire Protection Association, One Batterymarch Park, 

Quincy, MA 02269.

 

To supply the required 3 or 4 wire, single phase, 120/240 

volt, 60 Hz, AC only electrical supply (or 3 or 4 wire, 120/208 

volt electrical supply, if specified on the serial/rating plate) 

on a separate 30-amp circuit, fused on both sides of the line. 

Connect to an individual branch circuit. Do not have a fuse in 

the neutral or grounding circuit.

 

Do not use an extension cord.

 

If codes permit and a separate ground wire is used, it is 

recommended that a qualified electrician determine that the 

ground path is adequate.

If using a power supply cord:

Use a UL listed power supply cord kit marked for use with  

clothes dryers. The kit should contain:

 

A UL listed 30-amp power supply cord, rated 120/240 volt 

minimum. The cord should be type SRD or SRDT and be  

at least 4 ft. (1.22 m) long. The wires that connect to  

the dryer must end in ring terminals or spade terminals  

with upturned ends.

 

A UL listed strain relief.

Electrical Connection

To properly install your dryer, you must determine the type of 

electrical connection you will be using and follow the instructions 

provided for it here.

 

This dryer is manufactured ready to install with a 3-wire 

electrical supply connection. The neutral ground conductor  

is permanently connected to the neutral conductor (white 

wire) within the dryer. If the dryer is installed with a 4-wire 

electrical supply connection, the neutral ground conductor 

must be removed from the external ground connector (green 

screw), and secured under the neutral terminal (center or 

white wire) of the terminal block. When the neutral ground 

conductor is secured under the neutral terminal (center or 

white wire) of the terminal block, the dryer cabinet is isolated 

from the neutral conductor.

 

If local codes do not permit the connection of a neutral  

ground wire to the neutral wire, see “Optional 3-wire 

connection” section.

 

A 4-wire power supply connection must be used when the 

appliance is installed in a location where grounding through  

the neutral conductor is prohibited. Grounding through the 

neutral is prohibited for (1) new branch-circuit installations,  

(2) mobile homes, (3) recreational vehicles, and (4) areas  

where local codes prohibit grounding through the neutral 

conductors.

Spacing for recessed area or closet installation

The dimensions shown are for the recommended spacing 

allowed. 

 

Additional spacing should be considered for ease of 

installation and servicing.

 

Additional clearances might be required for wall, door, and 

floor moldings.

 

Additional spacing of 1" (25 mm) on all sides of the dryer is 

recommended to reduce noise transfer.

 

For closet installation, with a door, minimum ventilation 

openings in the top and bottom of the door are required. 

Louvered doors with equivalent ventilitation openings are 

acceptable.

 

Companion appliance spacing should also be considered.

Summary of Contents for MGDB835DC

Page 1: ...m ro de mod le _________________________________ Num ro de s rie ___________________________________ NOTES CONCERNANT L INSTALLATION Table des mati res S CURIT DE LA S CHEUSE 26 EXIGENCES D INSTALLATI...

Page 2: ...2 DRYER SAFETY IMPORTANT When discarding or storing your old clothes dryer remove the door...

Page 3: ...3...

Page 4: ...e wrench 8 203 mm or 10 254 mm adjustable wrench for gas connections Pipe joint compound resistant to LP gas Plastic putty knife INSTALLATION REQUIREMENTS Leveling legs 4 Tape measure Pliers Parts sup...

Page 5: ...ed within 4 ft 1 2 m of the water fill valves and water pressure of 20 100 psi 137 9 689 6 kPa You may use the water supply for your washer using the Y connector and short hose which are provided IMPO...

Page 6: ...d wire is used it is recommended that a qualified electrician determine that the ground path is adequate If using a power supply cord Use a UL listed power supply cord kit marked for use with clothes...

Page 7: ...h a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and...

Page 8: ...e is recommended 3 8 approved aluminum or copper tubing is acceptable for lengths under 20 ft 6 1 m if local codes and gas supplier permit If you are using Natural gas do not use copper tubing GAS SUP...

Page 9: ...used Do not use TEFLON tape Must include shut off valve In the U S A An individual manual shut off valve must be installed within six 6 ft 1 8 m of the dryer in accordance with the National Fuel Gas...

Page 10: ...wire connection 2 Remove terminal block cover Remove hold down screw and terminal block cover Put power supply cord through the strain relief Be sure that the wire insulation on the power supply cord...

Page 11: ...B Remove neutral ground wire E from external ground conductor screw A Reinstall ground conductor screw A B A E Prepare to connect neutral ground wire and neutral wire 1 B E C Connect neutral ground wi...

Page 12: ...g wires Connect remaining wires to outer terminal block screws Tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Ven...

Page 13: ...ection on this page If your wiring looks like this 4 wire Direct Wire Connection IMPORTANT A 4 wire connection is required for mobile homes and where local codes do not permit 3 wire connections Direc...

Page 14: ...t wire cable must have 5 ft 1 52 m of extra length so dryer may be moved if needed Strip 31 2 89 mm of outer covering from end of cable Strip insulation back 1 25 mm If using 3 wire cable with ground...

Page 15: ...nnect neutral ground wire E and neutral wire white or center wire C of power supply cord or cable under center terminal block screw B Tighten screw Connect remaining wires 3 Place hooked ends of remai...

Page 16: ...em and make sure exhaust hood is not plugged with lint Replace plastic or metal foil vents with rigid metal or flexible metal vents Review Vent System Chart and if necessary modify existing vent syste...

Page 17: ...from ground or any object that may obstruct exhaust such as flowers rocks bushes or snow Acceptable Style Optional exhaust installations Plan Vent System Recommended exhaust installations Typical ins...

Page 18: ...Chart to determine type of vent material and hood combinations acceptable to use NOTE Do not use vent runs longer than those specified in Vent System Chart Exhaust systems longer than those specified...

Page 19: ...r cold inlet hose to other side of Y connector Screw on coupling by hand until it is seated on connector Using pliers tighten the couplings an additional two thirds turn NOTE Do not overtighten Damage...

Page 20: ...outlet in dryer If connecting to existing vent make sure vent is clean Dryer vent must fit over dryer exhaust outlet and inside exhaust hood Check that vent is secured to exhaust hood with a 4 102 mm...

Page 21: ...f scale through the water system in the dryer Over time the buildup of lime scale may clog different parts of the water system which will reduce product performance Excessive scale buildup may lead to...

Page 22: ...surface with the inside of the door facing up 5 Install 2 plastic plugs A into screw holes where the hinges were removed in Step 4 Reverse the strike 1 Remove the door strike A from the dryer door ope...

Page 23: ...move the inner door by taking a plastic putty knife to separate the sides and bottom of the dryer door and trim There are 2 snaps on left right and bottom of door Insert the putty knife next to the sn...

Page 24: ...e right side of the door 6 Remove the door hinges and set off to the side 8 Lift door up and rotate trim pieces to the opposite side they were removed from Then screw trim pieces back in 5 Remove the...

Page 25: ...ce with the hinges lined up with the hinge holes 11 Install 6 hinge screws and the other 4 screws 12 Install hinge covers and plugs Hinge covers will go in sideways to then rotate 90 and snap into pla...

Page 26: ...26 S CURIT DE LA S CHEUSE IMPORTANT Pour mettre l ancienne s cheuse au rebut ou pour la remiser enlever la porte...

Page 27: ...27...

Page 28: ...ur Connecteur en Y Tuyau d alimentation court Tuyau d arriv e d eau de 5 1 52 m Rondelle en caoutchouc Pi ces n cessaires mod les vapeur Retirer le sachet de pi ces du tambour de la s cheuse V rifier...

Page 29: ...es valves de remplissage et une pression d eau de 20 100 lb po2 137 9 689 6 kPa L alimentation en eau de la laveuse peut tre utilis e avec le connecteur en Y et le tuyau court fournis IMPORTANT Ne pas...

Page 30: ...eut tre requis pour les moulures de porte et de plancher et pour les plinthes Un espace suppl mentaire de 1 25 mm de tous les c t s de la s cheuse est recommand pour r duire le transfert du bruit Un e...

Page 31: ...ifi d installer une prise de courant appropri e RACCORDEMENT LECTRIQUE DE LA S CHEUSE GAZ TATS UNIS ET CANADA SP CIFICATIONS LECTRIQUES AVERTISSEMENT Risque de choc lectrique Brancher sur une prise 3...

Page 32: ...tre le conduit et le joint conique de 3 8 C Connecteur obtur filetage NPT de 1 8 ou plus D Canalisation d alimentation en gaz filetage NPT de 1 2 E Robinet d arr t du gaz Option 2 m thode alternative...

Page 33: ...CATIONS DE L ALIMENTATION DU BR LEUR Altitudes sup rieures 2 000 pi 610 m Si la s cheuse doit tre utilis e une altitude sup rieure 2 000 pi 610 m on doit r duire le d bit thermique du br leur indiqu s...

Page 34: ...ation tel qu indiqu dans les Tableaux des syst mes d vacuation 4 102 mm Conduit d vacuation en m tal lourd de 4 102 mm Raccorder l alimentation en gaz la s cheuse 1 Retirer le capuchon rouge de la can...

Page 35: ...ation ne doit pas tre raccord ou fix avec des vis ou tout autre dispositif de serrage qui se prolongerait l int rieur du conduit et retiendrait la charpie Ne pas utiliser de ruban adh sif pour conduit...

Page 36: ...REMARQUE Ne pas utiliser de conduits de longueur sup rieure la valeur sp cifi e dans le tableau des syst mes d vacuation Si la longueur du circuit est sup rieure la valeur sp cifi e dans le tableau on...

Page 37: ...la laveuse Retirer l ancien joint de caoutchouc du tuyau d arriv e d eau et le remplacer par un joint de caoutchouc neuf Fermer l eau froide retirer et remplacer le joint de caoutchouc 1 Serrer les ra...

Page 38: ...nal 2 Placer la s cheuse son emplacement final viter d craser ou de d former le conduit d vacuation 57 8 150 mm 41 2 115 mm Fixer le long tuyau l lectrovanne de remplissage de la s cheuse et serrer le...

Page 39: ...Utilisation de la s cheuse dans le Guide d utilisation et d entretien Mod les lectriques q Pour une installation avec cordon d alimentation brancher sur une prise reli e la terre Pour une installatio...

Page 40: ...l o les charni res ont t retir es l tape 4 A B A B A A A A Outillage n cessaire Tournevis TORX T25 de 8 20 cm min de long Tournevis lame plate Couteau mastic en plastique Tournevis Phillips n 2 TORX...

Page 41: ...t te plate Elles sont munies d une ouverture pour y ins rer le tournevis et les extraire 2 Retirer les 10 vis de la porte de la s cheuse et les mettre de c t 3 Retirer la porte int rieure en s parant...

Page 42: ...a porte et les mettre de c t 8 Soulever la porte et faire pivoter les garnitures du c t oppos par rapport leur emplacement initial Ensuite revisser les garnitures en place 5 Retirer la cheville de la...

Page 43: ...arni res 11 Installer les 6 vis de charni re et les 4 autres vis 12 Installer les couvre charni res et les chevilles Les couvre charni res s ins rent de c t puis se pivotent 90 pour s embo ter en plac...

Page 44: ...W10725269A W10725272A SP 2014 All rights reserved Tous droits r serv s 06 14 Printed in U S A Imprim aux U...

Reviews: