Gas Dryer

PRODUCT MODEL NUMBERS
MGD6000X, MGD7000X, 

MGD9000X, MGD9000Y

Gas supply

This dryer is equipped for use with Natural 

gas. Dryer can be converted to L.P. gas. When rigid 

pipe is used it should be 1/2" IPS. When acceptable  

to the gas supplier and local codes, 3/8" approved  

tubing may be used for lengths under 20 ft (6.1 m).  

For lengths over 20 ft (6.1 m), larger tubing should be 

used. Pipe-joint compounds resistant to the action of 

L.P. gas must be used. An individual manual shutoff 

valve must be installed within 6 ft (1.8 m) of the dryer 

in accordance with the National Fuel Gas Code ANSI 

Z223.1. 

 

Electrical

A 120-volt, 60 Hz, AC-only, 15 or 20 amp 

fused electrical supply is required. A time-delay fuse or 

circuit breaker and a separate circuit are recommended. 

 

Water

 

(Steam models only)

The dryer must be  

connected to the cold water faucet using new inlet 

hoses. Do not use old hoses. Do not overtighten.  

Damage to the coupling can result.

A. Louvered hood  
B. Box hood 
C. Angled hood (acceptable) 

Because Whirlpool Corporation policy includes a continuous commitment to improve 

Dimensions are for planning purposes only. For complete details, see Installation 

our products, we reserve the right to change materials and specifications without notice. 

Instructions packed with product. Specifications subject to change without notice.

Ref. W10057364B 

03/2011

OVERALL DIMENSIONS

Dryer dimensions

For closet installation, with a 

door, the minimum ventilation 

openings in the top and bottom 

of the door are required. 

Louvered doors with equivalent 

air ventilation openings are 

acceptable.

Exhaust venting

Exhaust your dryer to the outside. 4" 

(102 mm) diameter vent is required. Rigid or flexible metal 

exhaust vent must be used. Do not use plastic  

or metal foil vet. Exhaust hood must be at least  

12" (305 mm) from the ground or any object that  

may be in the path of the exhaust.

The vent system chart provides venting requirments 

that will help to achieve the best drying performance.

Vent system chart:

  

NOTE:

 Side and bottom exhaust installations have  

a 90° turn inside the dryer. To determine maximum  

exhaust length, add one 90° turn to the chart.

Recommended installation clearances (dryer only)

Hood styles: A & B are recommended.

C

A

B

27"

(686 mm)

3

/

4

"*

(18 mm)

38

1

/

8

"

(968 mm)

31

1

/

8

"

(790 mm)

50

7

/

8

"

(1292 mm)

5

3

/

4

"*

(146 mm)

3

/

4

"*

(18 mm)

18" min.

(457 mm)

1"

(25 mm)

5"

(127 mm)

24 in.

min.

(155 cm

2

)

48 in.

min.

(310 cm

2

)

3"

(76 mm)

3"

(76 mm)

1"

(25 mm)

NOTE:

 Most installations require a 

minimum of 5" (127 mm) clearance  
behind dryer for exhaust vent with  
elbow. See “Venting Requirements.”

Approximate measurement

Front view:

Side view:

Back view:

Vent system chart

Number of 

90° elbows

Type  

of vent

Box/louvered

hoods

Angled  

hoods

1

4

3

2

0

Rigid metal

Rigid metal

Rigid metal

Rigid metal

Rigid metal

64 ft. (20 m)

54 ft. (16.5 m)

44 ft. (13.4 m)

35 ft. (10.7 m)

27 ft. (8.2 m)

58 ft. (17.7 m)

48 ft. (14.6 m)

38 ft. (11.6 m)

29 ft. (8.8 m)

21 ft. (6.4 m)

Do not use vent runs longer than specified in vent 

length chart.  

 

Determine the number of elbows you will need.

Select the route that will provide the straightest and most direct path outdoors.  

 

Plan the installation to use the fewest number of elbows and turns.  

 

Use the fewest 90° turns possible.

6

1

/

4

"

(159 mm)

29

7

/

8

"*

(759 mm)

3

1

/

2

"*

(89 mm)

5

3

/

4

"*

(146 mm)

6

1

/

8

"*

(156 mm)

14

3

/

8

"

(365 mm)

25

3

/

4

"

(654 mm)

3

/

4

"*

(18 mm)