Maytag MER6875BA Series Technical Information Download Page 4

Control Testing Procedures 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless  
testing requires power. 

16027361 4  July 

2006 

 

 

©2006 Maytag Services 

 

Control Feature 

Procedure 

Results 

H2.5 Oven 

Temperature 

Adjustment  
(Upper Oven) 

Press 

Upper Bake 

pad. 

Enter 

550

 on the digit-pad. 

Immediately press and hold 

Upper

 

Bake

 pad for 3 to 

5 seconds. 
Oven can be adjusted from -35 to +35 degrees in 5-
degree increments by pressing 

Autoset

 pad. To 

avoid over adjusting the oven, move temperature 5 
degrees each time. Wait 4 seconds for the data entry 
timer to expire to accept the change. Temperature 
adjustment will be retained even through a power 
failure

.

 

While increasing or decreasing oven 
temperature, oven self-cleaning 
temperature is not affected. 

H2.5 Oven 

Temperature 

Adjustment  
(Lower Oven) 

Press 

Lower Bake 

pad. 

Enter 

550

 on the digit-pad. 

Immediately press and hold 

Lower

 

Bake

 pad for 3 to 

5 seconds. 
Oven can be adjusted from -35 to +35 degrees in 5-
degree increments by pressing 

Autoset

 pad. To 

avoid over adjusting the oven, move temperature 5 
degrees each time. Wait 4 seconds for the data entry 
timer to expire to accept the change. Temperature 
adjustment will be retained even through a power 
failure

.

 

While increasing or decreasing oven 
temperature, oven self-cleaning 
temperature is not affected. 

H2.5 Temperature 

Display 

Press and hold 

Upper

 

Cancel

 and 

Upper

 

Bake

 

pads for 3 to 5 seconds. 

Indicates °F or °C on the display. 

H2.5 Clock 

Display  Press and hold 

Upper

 

Cancel

 and 

Clock

 pads for 3 

to 5 seconds. 

Turns clock display on or off. 

H2.5 24-Hour 

Clock  Press and hold 

Upper

 

Cancel

 and 

Favorite

 pads for 

3 to 5 seconds. 

Displays either 12-hour or 24-hour 
time format. 

H2.5 Factory 

Default Press and hold 

Upper

 

Cancel

 and 

Upper

 

Keep 

Warm

 pads for 3 to 5 seconds. 

Resets control to factory settings. 

H2.5 

12-Hour Off 

Control automatically cancels cooking operation and 
removes all relay drives 12 hours after the last pad 
touch. 

See Sabbath mode to disable. 

H2.5 Sabbath 

Mode  Hold 

Clock

 pad for 3 to 5 seconds to activate 

Sabbath mode. 
 
Hold 

Clock

 pad

 

for 3 to 5 seconds to disable 

Sabbath mode. 

"SAbbAth" displays for 5 seconds, 
then changes to "SAb" (displays in 
Temp area). 
All pad inputs are disabled except 

CANCEL

 and 

CLOCK

 pads. 

This mode disables the normal 12-
hour shutoff to allow operation of the 
bake mode for a maximum of 72 
hours. 

Summary of Contents for MER6875BA Series

Page 1: ...g 12 9 kW 9 7 kW Frequency 60 Hz Element Wattage 240 V Ribbon element 6 inch warmer 100 W Ribbon element 6 1 200 2 Ribbon element dual 9 2 400 1 100 Ribbon element triple 12 2 700 2 000 1 000 Convection Element 1 850 Oven Wattage 240 V Upper Bake 4 pass 1 800 Lower Bake 4 pass 2 600 Upper Broil 4 pass 2 200 Lower Broil 4 pass 3 000 Convection 1 850 Oven Interior Dimensions in cm Height 16 1 2 42 W...

Page 2: ...VAC If voltage is not present check wiring 2700 1000 1000W triple Measure voltage at element Disconnect wiring to element and measure cold resistance of terminals 240 VAC 700 W Outer Approx 82 Ω 1000 W Middle Approx 57 Ω 1000 W Inner Approx 57 Ω 1300 1100W dual Measure voltage at element Disconnect wiring to element and measure cold resistance of terminals 240 VAC 1300 W Outer Approx 43 Ω 1100 W I...

Page 3: ...ent Approximately 18 6 Ω 240 VAC see wiring diagram for terminal identification If voltage is not present at broil element check wiring Indicator lights Measure voltage at indicator light If voltage is present and light does not work replace light If voltage is not present at indicator light check wiring Rocker switch Measure continuity of switch positions Open Closed Infinite Continuity Door plun...

Page 4: ...ure 5 degrees each time Wait 4 seconds for the data entry timer to expire to accept the change Temperature adjustment will be retained even through a power failure While increasing or decreasing oven temperature oven self cleaning temperature is not affected H2 5 Temperature Display Press and hold Upper Cancel and Upper Bake pads for 3 to 5 seconds Indicates F or C on the display H2 5 Clock Displa...

Page 5: ...ile memory See Description of Error Codes for explanation Illustration Component Procedure Results Control Panel Assembly Continuity is indicated as follows Cancel and Warming Zone pads 6600 Ω max All other pads 10000 Ω max NOTE Pins 6 9 are jumped together in control NOTE Pins 1 10 and 11 18 are loops in circuit 1 18 11 10 Pad 1 2 3 4 5 6 7 8 9 0 Lower Cancel Lower Cancel Upper Cancel Upper Cance...

Page 6: ... BROIL CONVECT ELEMENT CONVECT FAN OVEN LIGHT IDLE r r r r BAKE PREHEAT r r BAKE r r BROIL PREHEAT r r r BROIL r r r CLEAN PREHEAT r r r r CLEAN r r r r KEEP WARM r r r CONVECT BAKE PREHEAT CONVECT BAKE CONVECT ROAST PREHEAT CONVECT ROAST PROOFING PREHEAT r r r PROOFING r r r DRYING PREHEAT r r DRYING r r During preheat cycle upper oven bake and broil elements are used at full power when lower ove...

Page 7: ...ion Fan on high speed CLEAN MDL relay activated COOK HOLD Displays last diagnostic code FAVORITE Displays EEPROM version number TIMER Displays main code version number CLOCK All display segments illuminated OVEN LIGHT Oven light activated CANCEL Exit Quick Test mode 1 Even segments on 2 Odd segments on 3 Convection Ring activated Convection Ring DLB activated 4 N A 5 N A 6 N A 7 N A 8 N A 9 N A AU...

Page 8: ...ables lights and timers 1c2c Keyboard loop improper value Nothing Disables audible for key depression Disables all outputs 1 Disables lights and timers 1c31 Cancel key improper value BAKE flashes 3 Disables all outputs for cavity 1 1c32 Cancel key improper value BAKE flashes 3 Disables all outputs for cavity 1 1c6c No response from EEPROM Nothing Disables all outputs 1 1c7c Calibration value out o...

Page 9: ...ked position is achieved The unlock position may be identified by a successful unlock switch closure or as the result of timing when the unlock switch is not functioning properly If the last known good position was unlock e g baking or idle and a latch fault occurs the motor is never moved The fault is logged to EEPROM and is not seen by the user Latch fault detection is in two stages The first st...

Page 10: ...am and Schematic WARNING To avoid risk of electrical shock personal injury or death disconnect power to range before servicing unless testing requires power 16027361 10 July 2006 2006 Maytag Services Wiring Diagram ...

Page 11: ... Schematic WARNING To avoid risk of electrical shock personal injury or death disconnect power to range before servicing unless testing requires power July 2006 11 16027361 2006 Maytag Services Schematic Control Circuits ...

Reviews: