18
Maytag Co.
450362 - 1
To Convert from Natural Gas to L.P. Gas
NOTE:
All dryers are sold as natural gas, unless otherwise specified at the time the dryer order
was placed. For L.P. gas the dryer must be converted as follows.
1.
Refer to “Replace Gas Valve” and follow steps 1 through 6.
2.
Remove the four screws which secure the top cap assembly. This assembly contains the regulator adjustment
screw and the terminal connections.
3.
Replace the top cap assembly with the L.P. version.
4.
Unscrew main burner orifices and replace with L.P. orifices.
NOTE:
Use extreme care when removing and replacing orifices. These orifices are made of brass
and are easily damaged.
5.
Reverse the procedure for reinstalling valve assembly to the dryer.
WARNING:
Test all connections for leaks by brushing on a soapy water solution. NEVER TEST
FOR LEAKS WITH A FLAME.
NOTE:
There is no regulator provided in an L.P. dryer. The L.P. gas pressure must be regulated at
the source (L.P. tank) or an external regulator must be added to each dryer.
To Replace Burner Tubes
1.
Refer to “Replace Gas Valve” and follow steps 1 through 6.
2.
Remove the two 7/16 nuts screws securing gas valve bracket to base of machine.
3.
Remove the two Torx T-20 screws securing the top and bottom burner tubes to the burner tube rest.
4.
Remove burner tubes by sliding them out.
5.
Replace by reversing procedure.
WARNING:
Test all connections for leaks by
brushing on a soapy water solution.
NEVER TEST FOR LEAKS WITH A
FLAME.
Do not modify this appliance.
Summary of Contents for MDG52
Page 34: ...Part No 450362 1 01 27 14 ...