background image

5

Installation

Handle Installation

If not installed, the handle is located in the interior of the
fresh food section or attached to the back of your refrig-
erator. Remove and discard handle packaging and tape.

Handle design varies from refrigerator to refrigerator.
Please reference the appropriate instructions for your
model.

Front Mount Handle with Extensions

Materials Needed

• Gloves to protect hands
• Phillips screwdriver
• Plastic door handle removal card (or 

1

32

" thick plastic

card), retain the card

Attach Extensions to Handle:

1. Align handle and

extension as shown.

2. Place extension in

handle opening.

3. Apply slight pressure

to both sides of the extension piece.

4. Slide extension until it stops on inside edge of

handle.

To Install:

1. The handles are to be oriented

as shown.

2. Align front mount door handle

clip with the door tabs.

3. Ensure the handle clips are

positioned slightly above the
door tabs.

4. Rotate the handle so that the

handle is flat against the door.

Handle

Clip

Door

Tab

Materials Needed

1

4

" outer diameter flexible copper tubing 

• Shut-off valve (requires a 

1

4

" hole to be drilled into

water supply line before valve attachment)

• Adjustable wrench

1

4

" hex nut driver

Note

• Add 8' to tubing length needed to reach water

supply for creation of service loop.

1. Create service loop with copper

tubing (minimum 2' diameter).
Avoid kinks in the copper tubing
when bending the service loop.

2. Remove plastic cap from water valve

inlet port.

3. Place brass nut (A) and

sleeve (B) on copper
tube end as illustrated.
(Do not use old sleeve.)

4. Place end of copper tubing into water

valve inlet port. Shape tubing slightly. Do
not kink – so that tubing feeds straight
into inlet port.

5. Slide brass nut over sleeve and screw nut

into inlet port. Tighten nut with wrench.

IMPORTANT: 

Do not overtighten. Cross

threading may occur.

6. Pull on tubing to confirm connection is

secure. Connect tubing to frame with
water tubing clamp (C) and turn on
water supply. Check for leaks and
correct if necessary. Continue to
observe the water supply connection
for two to three hours prior to moving
the refrigerator to its permanent
location.

7. Monitor water connection for 24 hours.

Correct leaks, if necessary.

C

A

B

2' diameter

minimum

Summary of Contents for MCD2257HEW - 22 cu. Ft. Refrigerator

Page 1: ...access Model Number _______________________________ Revision Number ______________________________ Serial Number ________________________________ Date of Purchase______________________________ In our...

Page 2: ...e Guide or published user repair instructions Do not attempt service if instructions are not under stood or if they are beyond personal skill level 13 Always disconnect refrigerator from electrical su...

Page 3: ...recess where the top of the refrigerator is completely covered use dimensions from floor to top of hinge cap to verify proper clearance Transporting Your Refrigerator NEVER transport refrigerator on i...

Page 4: ...f instructions are not understood or if they are beyond personal skill level Observe all local codes and ordinances Do not service ice maker unless specifically recommended in Use Care Guide or publis...

Page 5: ...Needed 1 4 outer diameter flexible copper tubing Shut off valve requires a 1 4 hole to be drilled into water supply line before valve attachment Adjustable wrench 1 4 hex nut driver Note Add 8 to tubi...

Page 6: ...s Slide handle upward approximately 3 4 to release 3 Repeat instructions 1 3 to remove other handle To Reinstall 1 Repeat in reverse order Door Clip 6 Align bottom of handle with lower door tab Press...

Page 7: ...roller adjustment screw counterclockwise Check with level to verify 1 4 tilt to the back for proper door closure If refrigerator is aligned and stable replace toe grille and hinge covers 7 Replace br...