DIAGNOSTIC CODES
If the set-up mode is entered and one of the following has occurred, the appropriate diagnostic code will be in
the display.
d1
Water level detection error on control board or due to power line interference (cycles and customer
display disabled until diagnostic code is manually cleared).
d3
Water temperature sense error when equipped with temperature sensing water valve (cycles will fill with
unregulated default water temperatures while the error persists).
d4
Washer lid sense error on control board or due to power line interference (cycles and customer display
disabled until diagnostic code is manually cleared).
d5
Blocked coin 1 or coin drop control circuit failure (coin recognition and price display disabled while
blockage persists).
PN MODELS ONLY:
Make sure cycle price is selected to zero and coin option is not selected.
(Set-up mode 6 should be set to 00 for free cycle operation. Set-up mode J. should be set to _d to
prevent coin drop diagnostic codes.)
d7
Last fill was slow.
d8
Last drain occurring during final spin was slow.
d9
Voltage detected below 180 vac for 8 seconds.
d12
Motor sense error detected on control board or due to power line interference.
d13
Blocked coin 2 or coin drop control circuit failure (coin recognition and price display disabled while
blockage persists).
TOP LOAD WASHER DIAGNOSTIC MODE
This mode is entered by depressing the
LOWER RIGHT
keypad for 1 second while in any of the set-up codes
1 through 6 anytime a diagnostic code is present, or while dAS displays if operating with Maytag Data
Acquisition setup.
On entry to diagnostic mode the entire display will flash, a cycle in process is cancelled, money in escrow is
cleared, and diagnostic codes are cleared. If a diagnostic code persists, it must be corrected before the fol-
lowing cycle options are permitted.
There are two possible ways to initiate cycle activity from diagnostic mode as follows:
1.
Field Diagnostic Cycle –
With the entire display flashing, this cycle is started by pressing the
LOWER
MIDDLE
key pad. This cycle provides a quick verification that the cold and hot water valves, pump, and
motor are working. It is also a method to quickly get into a drain and spin to remove water from the
machine if desired.
3 seconds cold fill “C” displayed
3 seconds hot fill “H” displayed
3 seconds warm fill “CH” displayed
3 seconds agitate “A” displayed
9 seconds spin “S” displayed
Pressing the
LOWER MIDDLE
key pad will pause/resume the cycle at any point during the diagnostic
cycle. Pressing the
LOWER RIGHT
key pad will exit diagnostic mode and cancel a diagnostic cycle in
process.
2.
Cycle Credit –
With the entire display flashing, a cycle may be credited by pressing the
LOWER LEFT
key pad (CC will display). When the service mode is exited “SELECT CYCLE” will be displayed unless