background image

28

REPAIR PARTS LIST

BURNER ASSEMBLY

MAYTAG GAS WATER HEATERS

MODEL NO’S

HRX75XQRS

75 Gallon Natural Gas

HRX75CQRS

75 Gallon Propane Gas

PROPANE BURNER ASSEMBLY

3

2

17

4

Now that you have purchased this gas water heater, should a need
ever exist for repair parts or service, simply 

call Maytag Customer

Service at 1-800-788-8899 for an authorized servicer.

 Be sure to

provide all pertinent facts when you call or visit.

THIS IS A REPAIR PARTS LIST, NOT A PACKING LIST.

The model number of this gas water heater will be found on the
model rating plate located near the gas control valve.

When ordering repair parts, always give the following information:

Model number

Serial Number

 * Integral to pilot assembly.

Key

                                                                   Model Number

 No.

Part Description

HRX75XQRS

HRX75CQRS

1

Anode Rod

66001109

66001109

2

Burner Head

9006200

66001834

3

Burner Orifice - Std.

66001689 (#21) 66001841 (#38)

4

Burner Tube

9006199

66001846

*5

Compression Fitting

66001837

66001837

6

Dip Tube

9006214

9006214

7

Draft Hood

66001678

66001678

*8

Draft Hood Bracket

66001679

66001679

9

Drain Valve

66001015

66001015

10

Drain Valve Washer

66001021

66001021

11

Flue Baffle

66001677

66001677

12

Gas Control Valve

66001680

66001773

13

Inner Door

66001692

66001692

*14

Instruction Manual

197667-001

197667-001

15

Nipple (Hot Outlet)

66001684

66001684

16

Outer Door

66001190

66001190

17

Pilot Ass’y - Std. w/Compression Fitting

9006201

66001848

18

Pilot Tube

--------

66001845

19

T & P  Relief Valve

66001682

66001682

20

Thermostat Shield (Optional)

66001667

66001667

21

Thermocouple

9000283

66001847

Part Description

Part Number

18

21

Maytag/State Part

 Number Conversion Key

MAYTAG

STATE

66001015

9002401

66001021

9001584

66001109

9001830

66001190

9000358

66001667

9003696

66001677

9003736

66001678

9003737

66001679

9003738

66001680

9003739

66001682

9003741

66001684

9003743

66001689

9003732

66001692

9003735

66001773

9003656

66001834

9004089

66001837

9004106

66001841

9004105

66001845

9003925

66001846

9004229

66001847

9004094

66001848

9004231

Summary of Contents for HRX75CQRSCGA

Page 1: ...FOR POTABLE WATER HEATING ONLY NOT SUITABLE FOR SPACE HEATING NOT FOR USE IN MANUFACTURED MOBILE HOMES Model Number HRX75XQRSCGA HRX75CQRSCGA For Your Safety AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER GAS WATER HEATER USER S GUIDE Series Ten ...

Page 2: ...uding a thorough understanding of the requirements of the Natural Gas and Propane Installation Code as it relates to the installation of gas fired water heaters The Service Specialist also has a thorough understanding of this instruction manual and is able to perform repairs strictly in accordance with the service guidelines provided by the manufacturer Gas Supplier The natural gas or propane util...

Page 3: ...3 SAFETY PRECAUTIONS ...

Page 4: ...13 14 Temperature Pressure Relief Valve 14 15 Filling the Water Heater 15 16 Venting 16 17 Gas Piping 17 18 Sediment Trap 18 OPERATING INSTRUCTIONS 19 21 Lighting Operating Label 19 20 Temperature Regulation 21 SERVICE AND MAINTENANCE 22 24 Tank Sediment Cleaning 22 Vent System Inspection 22 Burner Inspection 22 Burner Cleaning 22 23 Housekeeping 23 Anode Rod Inspection 23 Temperature Pressure Rel...

Page 5: ...per operation of the water heater and your safety Since we cannot put everything on the first few pages READ THE ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER The installation must conform with these instructions and local code authority having jurisdiction In the absence of local codes installations shall comply with the Natural Gas and Propane Installation Code CAN CSA B...

Page 6: ...SS AND 28 711 mm DIAMETER PART NO 66001012 FOR WATER HEATERS HAVING A DIAMETER 26 660 mm OR LESS Tools You may or may not need all these tools depending on your type of installation These tools can be purchased at your local hardware store Pipe Wrenches 2 14 356 mm Screwdriver Tin Snips 6 1 82 m Tape or Folding Ruler Garden Hose Drill Pipe Dope or Teflon Tape Additional Tools Needed When Sweat Sol...

Page 7: ... the vent pipe can be lifted off after any screw or other attached devices are removed Dispose of the draft hood The new water heater has the draft hood which must be used for proper operation 6 If you have copper piping to the water heater the two copper water pipes can be cut with a hacksaw approximately four inches away from where they connect to the water heater This will avoid cutting off pip...

Page 8: ...let Water Shut off Valve O Cold Water Inlet P Inlet Dip Tube Q Temperature Pressure Relief Valve R Rating Plate S Flue Baffle s T Thermostat U Drain Valve V Pilot and Main Burner W Flue X Drain Pan Y Thermostat Shield optional V PILOT MAIN BURNER NATURAL GAS T THERMOSTAT ALL PIPING MATERIALS TO BE SUPPLIED BY CUSTOMERS CLOSED WATER SYSTEMS ARE THOSE WITH BACK FLOW PREVENTION DEVICES INSTALLED IN T...

Page 9: ...g hot water in your home fits into one of these groups or if there is a local code or province law requiring a certain temperature water at the hot water tap then you must take special precautions In addition to using the lowest possible temperature setting that satisfies your hot water needs a means such as a Mixing Valve shall be used at the hot water taps used by these people or at the water he...

Page 10: ...ed by a leak detector or water shut off device used in conjunction with a piped drain pan These devices are available from some plumbing supply wholesalers and retailers and detect and react to leakage in various ways Sensors mounted in the drain pan that trigger an alarm or turn off the incoming water to the water heater when leakage is detected Sensors mounted in the drain pan that turn off the ...

Page 11: ... combustion air can result in a fire or explosion and cause death serious bodily injury or property damage FIGURE 10 If this water heater will be used in beauty shops barber shops cleaning establishments or self service laundries with dry cleaning equipment it is imperative that the water heater or water heaters be installed so that combustion and ventilation air be taken from outside these areas ...

Page 12: ...liances Located in Confined Spaces CONFINED SPACE is a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kW of the aggregate input rating of all appliances installed in that space A ALL AIR FROM INSIDE BUILDINGS See Figures 10 and 11 The confined space shall be provided with two permanent openings communicating directly with an additional room s of sufficient volume s...

Page 13: ...aces may create conditions requiring special attention to avoid unsatisfactory operation of installed gas utilization equipment Water Piping HOTTER WATER CAN SCALD Water heaters are intended to produce hot water Water heated to a temperature which will satisfy clothes washing dish washing cleaning and other sanitizing needs can scald and permanently injure you upon contact Some people are more lik...

Page 14: ...ntimely corrosion of hot and cold water fittings it is strongly recommended that di electric unions or couplings be installed on this water heater when connected to copper pipe Figure 16 shows the typical attachment of the water piping to the water heater The water heater is equipped with 1 NPT water connections for 75 gallon models NOTE If using copper tubing solder tubing to an adapter before at...

Page 15: ...nnect tubing directly to discharge drain unless a 6 inch air gap is provided To prevent bodily injury hazard to life or property damage the relief valve must be allowed to discharge water in quantities should circumstances demand If the discharge pipe is not connected to a drain or other suitable means the water flow may cause property damage FIGURE 17 The Discharge Pipe Shall not be smaller in si...

Page 16: ...of this gas fired water heater the correct vent pipe diameter must be utilized Any additions or deletions of other gas appliances on a common vent with this water heater may adversely affect the operation of the water heater Consult your Maytag Customer Service Center at 1 800 788 8899 or gas supplier if any such changes are planned For proper venting in certain installations a larger diameter ven...

Page 17: ...r square inch 3 5kPa the damage to the gas control valve could result in a fire or explosion from leaking gas If the main gas line Shut off serving all gas appliances is used also turn OFF the gas at each appliance Leave all gas appliances shut OFF until the water heater installation is complete A gas line of sufficient size must be run to the water heater Consult the current edition of the CAN CS...

Page 18: ...ystem at test pressures equal to or less than 1 2 pound per square inch 3 5kPa Connecting the gas piping to the gas control valve of the water heater can be accomplished by either of the two methods shown in Figures 20 and 21 Sediment Traps Contaminants in the gas lines may cause improper operation of the gas control valve that may result in fire or explosion Before attaching the gas line be sure ...

Page 19: ...19 OPERATING INSTRUCTIONS ...

Page 20: ...an or gas supplier If the pilot will not stay lit after several tries turn the gas control knob to OFF Figure A and call your service technician or gas supplier 9 Replace inner and outer burner doors 10 At arm s length away turn the gas control knob counterclockwise to on Figure C 11 Set thermostat to desired setting See Figure 1 CAUTION Hotter water increases the risk of scald injury Consult the ...

Page 21: ...g by up to 30 F 16 7 C If you experience this type of use you should consider using lower temperature settings to reduce scald hazards Any water heater s intended purpose is to heat water Hot water is needed for cleansing cleaning and sanitizing bodies dishes clothing Untempered hot water can present a scald hazard Depending on the time element and the people involved adults children elderly infir...

Page 22: ...r or your local gas supplier to correct the problem and clean or replace the flue and venting before resuming operation of the water heater Burner Inspection Flood damage to a water heater may not be readily visible or immediately detectable However over a period of time a flooded water heater will create dangerous conditions which can cause DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE Contact t...

Page 23: ...od that appears to be intact Replacement of a depleted anode rod can extend the life of your water heater Inspection should be conducted by a qualified technician At a minimum the anode s should be checked annually after the warranty period Temperature Pressure Relief Valve Operation The temperature pressure relief valve must be manually operated at least once a year When checking the temperature ...

Page 24: ...eck draft hood operation by performing a worst case depressurization of the building With all doors and windows closed and with all air handling equipment and exhaust fans operating such as furnaces clothes dryers range hoods and bathroom fans a match flame should still be drawn into the draft hood of the water heater with its burner firing If the flame is not drawn toward the draft hood shut off ...

Page 25: ...od see parts section for corrosion protection of the tank Certain water conditions will cause a reaction between this rod and the water The most common complaint associated with the anode rod is one of a rotten egg smell This odor is derived from hydrogen sulfide gas dissolved in the water The smell is the result of four factors which must all be present for the odor to develop a concentration of ...

Page 26: ...high water pressure in your area E The temperature pressure relief valve may be leaking at the tank fitting F Water from a drain valve may be due to the valve being slightly opened G The drain valve may be leaking at the tank fitting H Combustion products contain water vapor which can condense on the cooler surfaces of the tank Droplets form and drip onto the burner or run on the floor This is com...

Page 27: ...ol Replace Gas Control Dirty pilot burner Clean pilot assembly Thermocouple tip is not in contact with pilot flame Insert thermocouple correctly PILOT OUTAGE Thermocouple malfunction Replace pilot assembly and or thermocouple Defective Gas Control Replace Gas Control Heater not lit or thermostat not on Refer to LIGHTING INSTRUCTIONS Thermostat set too low Refer to TEMPERATURE REGULATION Heater und...

Page 28: ...9 66001846 5 Compression Fitting 66001837 66001837 6 Dip Tube 9006214 9006214 7 Draft Hood 66001678 66001678 8 Draft Hood Bracket 66001679 66001679 9 Drain Valve 66001015 66001015 10 Drain Valve Washer 66001021 66001021 11 Flue Baffle 66001677 66001677 12 Gas Control Valve 66001680 66001773 13 Inner Door 66001692 66001692 14 Instruction Manual 197667 001 197667 001 15 Nipple Hot Outlet 66001684 66...

Page 29: ......

Page 30: ...30 NOTES ...

Page 31: ...31 NOTES ...

Page 32: ...a leak occurs in the tank a new water heater of the closest capacity and quality then available will be replaced free of charge for the water heater with the owner paying all other costs including labor mileage and transportation If the water heater is subjected to commercial institutional industrial or non residential use the above warranty coverage for the tanks that are proved to be defective i...

Page 33: ...osion ou pour éviter tout dommage matériel toute blessure ou la mort Ne pas entreposer ni utiliser d essence ou ni d autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Ne touchez à aucun interrupteur ne pas vous servir des téléphones se trouvant dans le bâtiment Appelez immédiate...

Page 34: ...prend une connaissance approfondie des exigences du Code d installation du gaz naturel et du propane relatives à l installation des chauffe eau au gaz Le centre de service comprend en outre parfaitement le présent manuel d instructions et est en mesure d effectuer des réparations conformément aux directives d entretien du fabricant Fournisseur de gaz Entreprise ou service public de distribution de...

Page 35: ...3 MESURES DE SÉCURITÉ ...

Page 36: ...Tuyauterie de gaz 17 18 Collecteur d impuretés 18 INSTRUCTIONS DE FONCTIONNEMENT 19 21 Instructions d allumage et d utilisation 19 20 Réglage de la température 21 ENTRETIEN ET RÉPARATION 22 24 Nettoyage du réservoir dépôts 22 Inspection du système de ventilation 22 Inspection du brûleur 22 Nettoyage du brûleur 22 Entretien courant 23 Inspection de la tige d anode 23 Fonctionnement de la soupape de...

Page 37: ...uelques premières pages du manuel IL CONVIENT DE LIRE LA TOTALITÉ DU MANUEL AVANT D INSTALLER OU D UTILISERLECHAUFFE EAU L installation doit être conforme aux présentes directives et aux codes réglementaires locaux S il n existe pas de codes locaux l installation doit satisfaire au Code d installation du gaz naturel et du propane CAN CSA B149 1 On peut se procurer ce document auprès de l Associati...

Page 38: ...m OU MOINS Outils Suivant le type d installation les outils ci dessous peuvent être utiles Ils sont offerts dans les quincailleries Clé à tubes 2 14 po 356 mm Tournevis Cisaille de ferblantier Ruban à mesurer ou règle pliante de 6 pi 1 82 m Tuyau d arrosage Perceuse Pâte à joint ou ruban de téflon Outils supplémentaires requis pour la soudure à l étain Coupe tube ou scie à métaux Bouteille de prop...

Page 39: ...a plupart des cas on peut retirer l évent en le soulevant après avoir enlevé les vis ou autres pièces qui le retiennent Mettre l ancien coupe tirage au rebut car le nouveau chauffe eau exige un coupe tirage spécial 6 Si les conduites d eau sont en cuivre on peut tailler les deux tuyaux d eau avec une scie à métaux à environ quatre pouces du point de raccordement au chauffe eau Éviter de les couper...

Page 40: ...de combustion T Thermostat U Robinet de vidange V Veilleuse et brûleur principal W Conduit d évacuation des gaz de combustion X Bac d évacuation Y Dispositif de verrouillage pour thermostat optionnel V VEILLEUSE ET BRÛLEUR PRINCIPAL GAZ NATUREL T THERMOSTAT DISPOSITIF DE VERROUILLAGE POUR THERMOSTAT OPTIONNEL Y THERMOCOUPLE V VEILLEUSE ET BRÛLEUR PRINCIPAL PROPANE INSTALLER CONFORMÉMENT AUX CODES ...

Page 41: ...es les enfants et les personnes handicapées physiquement ou mentalement Si ces personnes utilisent l eau chaude ou si une loi provinciale ou un code local exige de limiter la température de l eau chaude aux robinets des précautions particulières doivent être prises En plus de régler la température au minimum on peut installer un dispositif tel qu une vanne de mélange à la sortie du chauffe eau ou ...

Page 42: ...d évacuation relié à un drain Ces dispositifs vendus dans certaines grandes quincailleries détectent les fuites et y réagissent de différentes manières Il peut s agir de capteurs fixés dans le bac d évacuation qui déclenchent une alarme ou coupent l arrivée d eau au chauffe eau lorsqu une fuite est détectée de capteurs fixés dans le bac d évacuation qui coupent l arrivée d eau principale de la mai...

Page 43: ...streindre la circulation de l air de ventilation En cas de doute ou pour des rensei gnements supplémentaires appeler le fournisseur de gaz Toute négligence à prévoir la quantité d air de combustion nécessaire peut causer un incendie ou une explosion et entraîner des blessures graves ou mortelles et des dommages matériels FIGURE10 Pour les installations dans un salon de beauté un salon de coiffure ...

Page 44: ...rage pare vapeur etc il faut prévoir un apport d air Pour ce faire utiliser une des méthodes décrites à la section Air de combustion et air de ventilation en espace clos Air de combustion et air de ventilation en espace clos On entend par ESPACE CLOS un espace dont le volume est inférieur à 50 pi3 par 1 000 Btu h 4 8 m3 kW de débit calori fique nominal total de tous les appareils installés dans ce...

Page 45: ...s créées par les foyers ou les dispositifs d évacuation mécanique L utilisation de ventilateurs d évacuation de systèmes de ventilation de sécheuses ou de foyers crée des conditions qui exigent une attention particulière pour éviter le fonctionnement insatisfaisant des appareils au gaz Tuyauterie d eau L EAU TRÈS CHAUDE PEUT OCCASIONNER DES BRÛLURES Les chauffe eau sont conçus pour produire de l e...

Page 46: ...agréé capable de remédier à la situation REMARQUE Si le chauffe eau est raccordé à une tuyauterie en cuivre il est fortement recommandé de lui installer des raccords ou manchons diélectriques pour protéger le système contre la corrosion prématurée des raccords de la tuyauterie d eau chaude et d eau froide La figure 16 présente le raccordement type de la tuyauterie d eau au chauffe eau Le chauffe e...

Page 47: ...voir Ne pas raccorder l extrémité de la conduite directement dans le drain d évacuation sans laisser un espace d air de 6 po Pour éliminer les risques de dommages matériels et de blessures graves ou mortelles la soupape de décharge doit être en mesure d évacuer la quantité d eau imposée par les circonstances Si la conduite d évacuation n est pas raccordée à un drain ou à un dispositif d évacuation...

Page 48: ...e diamètre suffisant Si d autres appareils au gaz partagent l évent tout ajout ou retrait d un appareil branché à l évent commun risque de nuire au fonctionnement du chauffe eau Pour obtenir plus de détails sur ce genre de changement consulter le centre de service à la clientèle Maytag au 1 800 788 8899 ou le fournisseur de gaz Dans certaines installations un évent de plus grand diamètre peut s av...

Page 49: ...t du type indiqué sur la plaque signalétique du chauffe eau La pression du gaz à l entrée du chauffe eau ne doit pas dépasser 14 po CE 2 6 kPa pour le gaz naturel ou le gaz propane GPL Si le régulateur de gaz est soumis à une pression dépassant 1 2 lb po2 3 5 kPa il peut être endommagé et causer des fuites de gaz entraînant des risques d incendie ou d explosion Si le système de distribution de gaz...

Page 50: ...on de gaz Pour les tests à une pression égale ou inférieure à 1 2 lb po2 3 5 kPa le chauffe eau n a pas à être coupé du système mais il doit être isolé de la conduite d alimentation de gaz par la fermeture de son robinet d arrêt Le raccordement de la conduite de gaz au régulateur de gaz du chauffe eau peut se faire suivant l une des méthodes représentées ci après fig 20 21 Collecteur d impuretés L...

Page 51: ...19 ...

Page 52: ...ens horaire 3 Enfoncez légèrement le bouton d admission du gaz puis tournez le dans le sens horaire jusqu à la position OFF FERMÉ fig A REMARQUE Ce bouton ne peut être tourné de la position PILOT VEILLEUSE à la position OFF que s il est légèrement enfoncé Ne le forcez pas 4 Retirez les panneaux d accès interne et externe se trouvant dessous et derrière la commande de gaz 5 Attendre cinq minutes po...

Page 53: ...pératures aux points de prélèvement qui dépassent de 30 F 16 7 C la température de consigne Avec ce type de consommation il est souhaitable de régler le thermostat à une température plus basse afin de réduire les risques de brûlures Le but de tout chauffe eau est de chauffer l eau L eau chaude non tempérée nécessaire pour le nettoyage le rinçage et la désinfection hygiène personnelle lave vaissell...

Page 54: ...réé ou avec le fournisseur de gaz afin de faire corriger le défaut et nettoyerouremplacerletuyaud évacuationdesgazetlesystème de ventilation avant de remettre le chauffe eau en marche Inspection du brûleur Les dégâts causés par l inondation d un chauffe eau ne sont pas toujours immédiatement visibles et décelables Cependant après un certain temps la détérioration progressive du chauffe eau peut ca...

Page 55: ... anode apparemment intacte Le remplacement de la tige d anode lorsqu elle est usée prolongera la durée de vie du chauffe eau L inspection de la tige d anode doit être faite par un technicien qualifié L inspection doit être faite au moins une fois par an après l expiration de la garantie Fonctionnement de la soupape de décharge à sécurité thermique La soupape de décharge doit être ouverte manuellem...

Page 56: ...e tirage Pour vérifier le fonctionnement du coupe tirage effectuer un test sous dépressurisation maximale du bâtiment Toutes les portes et les fenêtres étant fermées et tous les équipements de traitement de l air et ventilateurs d évacuation chaudières sécheuses hottes aspirantes et ventilateurs de salle de bain etc étant en marche allumer une allumette et vérifier que la flamme est attirée par le...

Page 57: ...ertains bruits produits par la dilatation et la contraction de pièces métalliques pendant les cycles de réchauffement et de refroidissement n indiquent pas la présence d une situation nuisible ou dangereuse Pendant les périodes d échauffement et de refroidissement la condensation cause un grésillement et un bruit de craque ment dans la région du brûleur Ces bruits sont considérés comme normaux Voi...

Page 58: ...ns un raccord C Eau sur le raccord de la tige d anode Fuite possible D Léger écoulement d eau de la soupape de décharge à sécurité thermique Peut être causé par la dilatation thermique de l eau du système ou par une pression d alimentation d eau élevée E Fuite possible de la soupape de décharge au niveau du raccord avec le réservoir F Un écoulement d eau peut apparaître à la sortie du robinet de v...

Page 59: ...ocouple non en contact avec Insérer le thermocouple convenablement la flamme de la veilleuse Mauvais fonctionnement du thermocouple Remplacer la veilleuse ou le thermocouple Commande de gaz défectueuse Remplacer la commande de gaz Chauffe eau éteint ou thermostat fermé Voir les instructions d allumage Thermostat réglé trop bas Voir la section Réglage de la température Chauffe eau de capacité insuf...

Page 60: ...itif de verrouillage pour thermostat optionnel 66001667 66001667 21 Thermocouple 9000283 66001847 18 21 No DE MODÈLE HRX75XQRS 75 gallons au gaz naturel HRX75CQRS 75 gallons au gaz propane Pour des pièces de rechange à l occasion d un service d entretien ou de réparation communiquer avec le service à la clientèle Maytag au 1 800 788 8899 pour obtenir le nom d un agent de service agréé Lors de l ap...

Page 61: ...29 NOTES ...

Page 62: ...30 NOTES ...

Page 63: ...31 NOTES ...

Page 64: ...le chauffe eau est remplacé par un chauffe eau neuf de capacité et de qualité les plus équivalentes possible gratuit les autres frais dont les frais de main d œuvre de déplacement et de transport devant être acquittés par le propriétaire Si le chauffe eau fait l objet d un usage commercial institutionnel industriel ou non résidentiel la période de couverture ci dessus pour les réservoirs avérés dé...

Reviews: