Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless
testing requires it.
22 16022506
©2003 Maytag Appliances Company
Test Mode
Follow procedure below to access the Test Mode.
1. Press
SETUP pad.
2. Press
DOWN ARROW pad three times until SERVICE is displayed.
3. Press
SERVICE pad.
4. Press
and
hold
BACK and ENTER pads for 5 seconds.
5. Press
TEST pad.
NOTE: If the oven cavity temperature is greater then 400
°
F, the Test Mode cannot be activated or will abort the
mode if activated.
NOTE: Once the Test Mode is activated and a function is selected the control will activate the relay until the pad is
pressed again. Upon entering TEST Mode all relays are turned off except the DLB relays, which are turned
on. All relays are turned off when the TEST Mode is exited.
Pad Pressed Relay
or
Action
Activated
Beep
1 Second Beep
Version Version
of
software
Last Fault
Display last error code and oven configuration (single, double, convection, nonconvection)
DISP Test
Display segments
UBAKE Upper
Bake
Element
UBROIL Upper
Broil
Element
UCONV
Upper Convection Element
UCOOL
Upper Cooling Fan
UCONV-H
Upper High Speed Convection Fan
UCONV-L
Upper Low Speed Convection Fan
UMDL
Upper Motorized Door Lock
ULITE
Upper Oven Light
LBAKE
Lower Bake Element
LBROIL Lower
Broil
Element
LCONV
Lower Convection Element
LCOOL
Lower Cooling Fan
LCONV-H
Lower High Speed Convection Fan
LCONV-L
Lower Low Speed Convection Fan
LMDL
Lower Motorized Door Lock
LLITE
Lower Oven Light