44
Preventative function monitoring
Through the monitoring of different parameters, the ROBA
®
-brake-checker recognises safety critical operating conditions of the
brake in advance, as well as acute faults (e.g. line breakage). These are determined as they occur and are notified to the user
as a warning before the brake can no longer be operated.
Only the mechanical switching function is checked. Conclusions on the braking torque are not possible (e.g. reduced friction
value due to oiling of the brake lining)
Possible causes for the warning:
• Increasing wear
• Rising coil temperature
• Falling supply voltage
• Line voltage drop on feed lines to the brake
Technical Data
Size 20
Supply voltage control
terminal
SELV/PELV
ripple
content ≤5 %
U
I
[VDC]
24
(7 - 30)
Coil current
max.
I
max
[A]
3.5
at ≤45 °C
I
RMS
[A]
3.5
at ≤60 °C
I
RMS
[A]
3
at ≤70 °C
I
RMS
[A]
3
Device fuses
Control terminal
Fuse 315 mA, slow acting
Power terminal
Max. 4 A circuit breaker, characteristic K/Z
(rated brake current)
Protection
IP20
Terminals
Control terminal
Nominal cross-section 0.34 – 2.5 mm² (22 – 14 AWG)
Tightening torque, screws: 0.5 – 0.6 Nm/3.6 lb-in
Power terminal
Nominal cross-section 0.14 – 2.5 mm² (30 – 12 AWG)
Tightening torque, screws: 0.5 – 0.6 Nm/5 - 7 lb-in
Device ambient temperature
[°C]
-25 to +70 / -25 to +60
Storage temperature
[°C]
-40 to +105
Conformity markings
Protection
IP20
Installation conditions
The installation position can be user-defined.
Please ensure sufficient heat dissipation and air convection!
Do not install near to sources of intense heat!
Size
Type
Input voltage
± 10%
[VDC]
Brake nominal voltage
[VDC]
Article number
20
059.500.2
max. 207
104
8259978
059.500.2
max. 432 / 320
1)
207 / 180
8260167
059.500.2 SO
2)
max. 207
8261306
1) CSA-C22.2 No. 14
2) Customer specific designs
44