POSSIBLE CHARGING PROBLEMS 

PROBLEM 

CAUSE 

SOLUTION 

 
 
 
 

Faulty  Battery 

The battery voltage is lower 
than 11V, after charging for 4 
minutes; 

 

The battery voltage falls 
below 12V, within 2 minutes 
of being fully charged; 

 

Failed to reach fully charged 
status 

 
 
 
Have the battery tested by a qualified technician. 
Replace the battery if necessary. 
 

 

 

 

 
 
 
 
 

Battery not accepting 
a charge

 

Lack of AC input power 

Make sure

 that the charger is plugged into AC outlet and the 

POWER LED is lit. 

Faulty connections to battery 
terminals 
 

Unplug the charger

 and check the battery connection; ensure that 

there is a good connection at the battery terminals and/or the 
vehicle chassis. 
Ensure enough charging time was allowed to charge battery. 

Battery voltage too low 
 

The Red LED will continue

 to flash when the battery voltage is 

less than 2.0V.

 

Charging a very cold battery 

If the battery to be charged

 is extremely cold (in temperatures 

below freezing 0

), it will not accept a high rate of charge, so the 

initial charger rate will be slow. The rate of charger will increase as 
the battery warms. Never attempt to charge a frozen battery.

 

 
MAINTENANCE INSTRUCTIONS 

This charger requires minimal maintenance. As with any appliance or tool, a few common sense rules will prolong the life of the battery 
charger. 
ALWAYS BE SURE THE CHARGER IS UNPLUGGED BEFORE PERFORMING ANY MAINTENANCE OR CLEANING. 
1. Store in a clean, dry place 
2. Coil up the cords when not in use. 
3. Clean the case and cords with a slightly damp cloth. 
4. Clean any corrosion from the clamps with a solution of water and baking soda. 
5. Examine the cords periodically for cracking or other damage and have them replaced if necessary. 
6. WARNING: All other service should be done by qualified personnel only. 

 

TECHNICAL SPECIFICATIONS 

Protection class 

Input  

voltage 

Input 

current 

Output 

Max Lead-acid  

battery capacity 

IP20 

220-240V 

50Hz 

0.2A 

12V / 0.5A 

Max100Ah 

 
DISPOSAL

 

In the event that this product must be disposed of, an authorised place for the recycling of electrical and electronic appliances 
must be sought.  Contact your local authority for information concerning local Household Recycling Centres with applicable 
facilities. 

This product must not be disposed of with general domestic waste.

 

 

DECLARATION OF CONFORMITY 

We declare that this product conforms to the following standards EN60335-1, EN60335-2-29, EN55014, EN61000, and the 
following Directives 73/23 CEE, 93/68 CEE, 2004/108/EC, 2002/95/EC (ROHS),  

 

Technical Manager 

Maypole Ltd 

November, 2015 

EMAIL :   

[email protected]

 

WEB 

 

www.maypole.ltd.uk

 