POSSIBLE CHARGING PROBLEMS
PROBLEM
CAUSE
SOLUTION
Faulty Battery
The battery voltage is lower
than 11V, after charging for 4
minutes;
The battery voltage falls
below 12V, within 2 minutes
of being fully charged;
Failed to reach fully charged
status
Have the battery tested by a qualified technician.
Replace the battery if necessary.
Battery not accepting
a charge
Lack of AC input power
Make sure
that the charger is plugged into AC outlet and the
POWER LED is lit.
Faulty connections to battery
terminals
Unplug the charger
and check the battery connection; ensure that
there is a good connection at the battery terminals and/or the
vehicle chassis.
Ensure enough charging time was allowed to charge battery.
Battery voltage too low
The Red LED will continue
to flash when the battery voltage is
less than 2.0V.
Charging a very cold battery
If the battery to be charged
is extremely cold (in temperatures
below freezing 0
℃
), it will not accept a high rate of charge, so the
initial charger rate will be slow. The rate of charger will increase as
the battery warms. Never attempt to charge a frozen battery.
MAINTENANCE INSTRUCTIONS
This charger requires minimal maintenance. As with any appliance or tool, a few common sense rules will prolong the life of the battery
charger.
ALWAYS BE SURE THE CHARGER IS UNPLUGGED BEFORE PERFORMING ANY MAINTENANCE OR CLEANING.
1. Store in a clean, dry place
2. Coil up the cords when not in use.
3. Clean the case and cords with a slightly damp cloth.
4. Clean any corrosion from the clamps with a solution of water and baking soda.
5. Examine the cords periodically for cracking or other damage and have them replaced if necessary.
6. WARNING: All other service should be done by qualified personnel only.
TECHNICAL SPECIFICATIONS
Protection class
Input
voltage
Input
current
Output
Max Lead-acid
battery capacity
IP20
220-240V
50Hz
0.2A
12V / 0.5A
Max100Ah
DISPOSAL
In the event that this product must be disposed of, an authorised place for the recycling of electrical and electronic appliances
must be sought. Contact your local authority for information concerning local Household Recycling Centres with applicable
facilities.
This product must not be disposed of with general domestic waste.
DECLARATION OF CONFORMITY
We declare that this product conforms to the following standards EN60335-1, EN60335-2-29, EN55014, EN61000, and the
following Directives 73/23 CEE, 93/68 CEE, 2004/108/EC, 2002/95/EC (ROHS),
Technical Manager
Maypole Ltd
November, 2015
EMAIL :
WEB
:
www.maypole.ltd.uk