background image

 

13 

Warnings 

1. Safety precautions   

a.  To avoid fire, do not dry clothes or leave any towels in the sauna room.    Do not cover the floor heater with any 

towels. 

b.  Do not install the sauna near water, near a bathtub, near a shower, in a wet basement, or near a swimming pool.  

c.  To prevent burns or electric shocks, do not touch or use metal tools on the protective material covers of the heat 

emitter panels. 

d.  When replacement parts are required, be sure they meet the specified requirements of the manufacturer.   

Unauthorized substitutes may result in fire, electric shock, or other hazardous conditions.    After any repairs, 

please perform safety checks to determine that your sauna is working properly. 

e.  While in the sauna, do not touch the light bulb. If the bulb needs to be changed, switch it off and wait until the 

sauna is shut off and the bulb is cool. 

f. 

Do not use any wall receptacle adapter or extension cord between the sauna cord and wall receptacle.    An 

applicable heavy duty surge protector can be used.

 

g.  Do not spray water on the heat emitter panels.    This may result in electric shock or damage to the heat 

emitters. 

h.  Always consult your physician for medical advice before using the sauna room.   

i. 

Do not use the sauna if you have any of the following conditions below:   

1.  Open wounds 

2.  Eye diseases 

3.  Severe sunburns 

4.  The elderly & weak.    Those suffering from any medical condition or disease.      Pregnant women and 

children should not use the sauna room.    Children should not use the sauna unless prescribed by a 

medical physician and under the supervision of an adult. 

5.  If suffering from a disease directly related to temperature, seek the advice of a medical physician before 

using the sauna. 

6.  Do not place pets in the sauna. 

7.  Never use the sauna if you are taking medications or consuming alcohol.   

 

 

Troubleshooting: 

 

problem 

possible reason 

countermeasure 

indicator light for power 

supply not working 

The connector is not connected 

properly 

Check the connector or replace a new 

one 

No power supply input 

Check your circuit breaker to confirm 

power at the wall outlet   

Indicator light is broken 

replace the circuit panel 

Indicator light for function 

is not working 

The heating indicator light is broken 

Replace the relevant control panel 

The circuit board or components are 

broken 

Replace the circuit board 

The temperature sensor is broken 

check the connection of the 

temperature sensor 

Summary of Contents for MX-K106-01

Page 1: ...s MX K106 01 MX K206 01 MX K306 01 MX K406 01 FOR CARBON MODEL SAUNAS HEMLOCK AND RED CEDAR MODELS FOR INDOOR USE ONLY 120V 15AMP DEDICATED CIRCUIT REQUIRED FOR MX K106 01 MX K206 01 120V 20AMP DEDICA...

Page 2: ...r a wide range of possible therapeutic benefits based on research completed over the last 25 years from all around the world These benefits are presented for reference purposes only and no implication...

Page 3: ...hers may affect the heart rate blood pressure and or blood circulation G WARNING Your hands must be dry and free of moisture before plugging and unplugging cords and wiring harnesses from the power su...

Page 4: ...nds of users enjoy the benefits of infrared saunas every day Infrared saunas help you burn calories reduce toxins relieve pain and even clear complexions Now you can enjoy the great benefits of far in...

Page 5: ...the designated sauna connections plugs c Assemble the sauna room on a completely level surface d Do not spray or get water on the exterior interior walls of the sauna room If the floor is damp install...

Page 6: ...n saunas are packed in three cartons For example C NO 002 1 OF 3 C NO 002 2 OF 3 and C NO 002 3 OF 3 See FIG 2 1 2 2 FIG 2 1 Cartons FIG 2 2 C No 4 Place the Floor Panel on a smooth flat surface and m...

Page 7: ...Floor Panel s corresponding wood pattern make sure the Left Side Panel fits flush into the Back Panel See FIG 5 FIG 5 Assembling Left Side Panel FIG 6 Buckle 7 For model MX K106 01 you will use the pr...

Page 8: ...er Panel slots Please note there is a pre cut small hole under the Bench Heater Panel which is provided for the Floor Heater cord This cord will connect the Floor Heater to the plug outlet on the Left...

Page 9: ...avoid breakage See FIG 11 FIG 11 Assembling Front Panel FIG 12 Installing Roof Cover 12 Place cords wires of Front Panel and Back Panel into the sauna room area to avoid damaging the cords wires duri...

Page 10: ...Roof Panel The CD Player radio is not available on model MX K106 01 14 The CD Player will already be mounted in its wood housing box Connect the antenna to the CD player Next feed the wires up throug...

Page 11: ...sponds accordingly then proceed in putting the Roof Cover onto the Roof Panel Make sure to pull the power cord through the corresponding hole in the Roof Cover See FIG 17 FIG 17 Slip the power cord th...

Page 12: ...hour e To avoid burns do not touch the heating element 2 Operating The Sauna a Review the electrical label on the sauna and then plug the sauna into the proper wall outlet No other appliance can be o...

Page 13: ...through a sequence of the different shades of colors B The second selection for white will continue to display the white light 5 To return back to the Timer mode press the button e You can operate th...

Page 14: ...o the heat emitters h Always consult your physician for medical advice before using the sauna room i Do not use the sauna if you have any of the following conditions below 1 Open wounds 2 Eye diseases...

Page 15: ...er at the wall outlet Power supply or circuit panel is broken Replace the power supply or related circuit board 7 The temperature display shows EP The connector of temperature sensor is loose not conn...

Page 16: ...auna NOTE Any chemical that can damage wood or be absorbed into the wood will damage the sauna Transportation and storage 1 Avoid exposure to rain snow or other strong weather elements 2 Do not store...

Page 17: ...change manufactures of any part to cover any existing warranty Any parts determined to be defective must be returned to Golden Designs Inc to obtain warranty service You must prepay any shipping charg...

Page 18: ...y person or damage to any property however arising Specifications are subject to change without notice or obligation Legal Remedies This limited warranty gives you specific legal rights You may have o...

Page 19: ...d is not mailed back within 60 days of purchase date along with proof of purchase Serial number S N is located on the sauna s front panel rear panel or on the carton DETACH HERE WARRANTY CARD All fiel...

Reviews: