7
7.
Electrical installation:
Wires from the power supply to the unit should not be smaller than size 14 AWG.
The ground wire must be connected to the green wire in junction box, the neutral wire
to the white wire and the hot wire to the black wire.
Installation II (
remodeling
)
1.
In case there is a ventilation unit with the same dimensions in the ceiling,
proceed as follows:
Remove the old unit;
Check the existing duct work and electrical wiring;
Install the unit as described in Installation I.
2.
In case you want to make a new opening in existing ceiling:
Find the best location for the ventilation purpose;
Make sure that :
−
the chosen place has easy access
to exterior air outlet (wall cap or roof
jack) and there will not be a need
for sharp angles or very long duct;
−
the chosen place for the duct work will
not interfere with any other existing
duct work in the
building;
−
there is no electrical wiring or
any pipes behind the chosen place;
Open the optimal place.
Be careful to
cut the hole exactly. If the hole is too
big, the fan grille will not hide it;
Make the strong support beams for
the unit (make sure it is strong enough
for the weight of the unit);
Provide the duct system and electrical wiring;
Follow the instructions on Installation I.
Ceiling
4 long screws
I-joist
8.
Grille installation:
Pinch the mounting springs on the grille
and insert them into the narrow
rectangular slots inside the fan
.
Push grille up towards the ceiling.
Turn power on at the breaker box after installation.
Grille
Mounting
spring