4. MAINTENANCE

4.1.   The repairs or maintenance operations must only be carried out by qualified personnel.

4.2.   The unit must be checked by a qualified technician at least once a year.

4.3.   Regularly check the conditions of gas hose, and gas regulator if it must be replaced only use  

 

original spare parts.

4.4.   Before starting any maintenance operation on the heater disconnect from both gas and    
 

electrical suppliers.

4.5.   If the unit has not been used for a long period we advise that a technician carries out a 
 

general check up before using. It is important to control the following:

4.5.1. Periodically check the gas supply hose conditions and, should it be changed, use only 
 

original spare parts.

4.5.2. Check the starting electrode position (see Fig.5).

                                   

4.5.3. Check the connections of the safety thermostat and of the thermocouple: they must always  
 

be clean. 

 

If necessary clean the fan blade and the inside of the heater using compressed air.

5. TROUBLESHOOTING

Automatic ignition models

Automatic ignition models 
PROBEM 

CAUSES 

SOLUTIONS 

The motor does not work 

No electricity supply 

Check the terminal board with a tester 

The room thermostat is regulated too low 

Regulate the thermostat on a higher temperature 

The safety thermostat is on 

Wait about one minute then push the RESET button 

The motor works, but the 

burner does not light up 

and after few seconds 

the heater stops 

The cylinder gas tap is closed 

Open the gas tap 

The cylinder is empty 

Use a new cylinder 

The nozzle is obstructed 

Remove the nozzle and clean it. 

The solenoid gas valve is not open 

Check that the solenoid valve works 

There is no spark 

Check the position of electrode 

The burner lights up 

 

but after few seconds the 

heater stops 

No connection with the earthing system   

Check and connect properly 

Defective connection between sensor and 

safety device 

Check and connect properly 

Defective safety device 

Replace the safety device 

The heater stops during 

operation 

Excessive gas supply 

Check the pressure reducer and if required replace it 

Insufficient air flow 

Check that the motor works properly 

Insufficient gas supply due to ice formation on 

the cylinder 

Check and use a larger cylinder or two cylinders 

connected together. 

 