![MaxxHome 20719 Instruction Manual Download Page 7](http://html1.mh-extra.com/html/maxxhome/20719/20719_instruction-manual_1746839007.webp)
4. MAINTENANCE
4.1. The repairs or maintenance operations must only be carried out by qualified personnel.
4.2. The unit must be checked by a qualified technician at least once a year.
4.3. Regularly check the conditions of gas hose, and gas regulator if it must be replaced only use
original spare parts.
4.4. Before starting any maintenance operation on the heater disconnect from both gas and
electrical suppliers.
4.5. If the unit has not been used for a long period we advise that a technician carries out a
general check up before using. It is important to control the following:
4.5.1. Periodically check the gas supply hose conditions and, should it be changed, use only
original spare parts.
4.5.2. Check the starting electrode position (see Fig.5).
4.5.3. Check the connections of the safety thermostat and of the thermocouple: they must always
be clean.
If necessary clean the fan blade and the inside of the heater using compressed air.
5. TROUBLESHOOTING
Automatic ignition models
Automatic ignition models
PROBEM
CAUSES
SOLUTIONS
The motor does not work
No electricity supply
Check the terminal board with a tester
The room thermostat is regulated too low
Regulate the thermostat on a higher temperature
The safety thermostat is on
Wait about one minute then push the RESET button
The motor works, but the
burner does not light up
and after few seconds
the heater stops
The cylinder gas tap is closed
Open the gas tap
The cylinder is empty
Use a new cylinder
The nozzle is obstructed
Remove the nozzle and clean it.
The solenoid gas valve is not open
Check that the solenoid valve works
There is no spark
Check the position of electrode
The burner lights up
but after few seconds the
heater stops
No connection with the earthing system
Check and connect properly
Defective connection between sensor and
safety device
Check and connect properly
Defective safety device
Replace the safety device
The heater stops during
operation
Excessive gas supply
Check the pressure reducer and if required replace it
Insufficient air flow
Check that the motor works properly
Insufficient gas supply due to ice formation on
the cylinder
Check and use a larger cylinder or two cylinders
connected together.