1. Lift louver vane above the
damaged louver vane to
be replaced. This will give
better access to the linkage
pins that need to be
removed on the damaged
louver vane. (
Fig.1 & 2
)
2.
Using a standard (flat-
head) screwdriver, press
the pin back into the
linkage pin housing. Grasp
the head of the linkage
pin with pliers and apply
steady pressure to pull
the linkage pin out of the
linkage pin housing. Pry
the linkage pin assembly
out of the nylon retainer
washer and linkage strip.
Repeat for the remaining
linkage pins on the louver
vane to be replaced.
(
Fig. 3
)
3. Remove the screws that
secure the IF unit to the
wall on the top, bottom
and one side (left or right
side does not matter).
Keep these screws to
reinstall the IF unit later.
Carefully pry the IF unit
away from the wall on the
INSTRUCTIONS
Fig.1 - Damaged louver vane needs
replacing
Fig.2 - Location of linkage pins and
linkage strip behind louver
Fig.3 - Use flat-head screw driver to
remove linkage pins