Step 4 (Living space):    

 

Slide the damper box assembly up into the hole and secure it to the ceiling structure using a minimum of a two 
inch (2”) long wood or sheetrock screws.  Be sure to avoid installing these screws toward the middle of the 
damper assembly flanges as the intake grille will screw in at the middle of the damper box flanges as shown in 
Figure C.  These screws will pass through the ceiling material and into the wooden ceiling joists or lumber in the 
attic above ensuring a secure installation of the damper box. 

 

Step 5 (Attic):   

 

Determine to which roof rafter the fan will be mounted.  The location of the fan installation will need to be less 
than 10 feet away from the damper box assembly due to the length of the provided duct.  The further away from 
the damper box assembly the fan can be installed the quieter the apparent operation of the fan will be in the living 
space below. 

 

Using a 3/8” drill bit, drill a hole in the location chosen.  This hole needs to be 1-½” up from the long, flat edge of 
the rafter as shown in Figure D. 

 

Attach the rafter bracket to the top of the fan hanging bracket using the provided 5/16” x ¾” bolt, lock nut and 
washers. 

 

Attach the rafter bracket to the rafter where the hole was drilled using the provided 5/16” x 2-½” bolt and lock nut 
as shown in Figure D.  

 

Ensure all nuts and bolts are tight on the mounting components of the fan. 

 

If possible, manually spin the fan blade to ensure there are no obstructions that may have occurred during 
shipping, handling or installation. 

Note: Avoid placing screws in the middle when mounting the damper box.  This area is used to 

secure the grille in a later step. 

Summary of Contents for CX1401

Page 1: ...er hidden utilities d WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICE e Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer f Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on a...

Page 2: ...surface size in half DO NOT OVERSIZE YOUR FAN Additional installation of exterior vents may be required to provide sufficient Net Free Exhaust Area NFA for your fan to operate safely and effectively Remember bigger is not always better with Whole House Fans A smaller fan that operates efficiently will always be preferable to a fan that is too big for its application Tools Needed Materials Needed D...

Page 3: ...ind a spot where you would like to install the damper assembly drill a small hole in the middle of this location in the ceiling material and feed a wire through to mark it in the attic space above Step 2 In the attic Find the wire that was fed through the ceiling below and check for wires pipes and other obstructions around the area where the product will be installed If anything is in the way of ...

Page 4: ...gle to use as guides for cutting the ceiling material from the living space below as shown in Figure A Optional but recommended Measure the exact length between the two ceiling joists between which you have marked the rectangle Cut two pieces of lumber 2x4 or larger to fit in between the two ceiling joists Place these pieces of lumber flush with the ceiling material in the attic and running in bet...

Page 5: ... from the damper box assembly due to the length of the provided duct The further away from the damper box assembly the fan can be installed the quieter the apparent operation of the fan will be in the living space below Using a 3 8 drill bit drill a hole in the location chosen This hole needs to be 1 up from the long flat edge of the rafter as shown in Figure D Attach the rafter bracket to the top...

Page 6: ...ion down to the damper assembly box Fit the duct transition over the top of the damper assembly box Ensure that it sits flush against the top of the damper assembly box as shown in Figure E Use the provided foil tape to seal the seam between the duct transition and damper assembly box to prevent air leakage when the unit is running D ...

Page 7: ...ce plate Keep these screws to re close the wiring box after wiring is completed Run a length of three conductor wire in between the fan wiring box and the location in the living space below where the switches will be installed There should also be the two conductor wire run from the power supply panel or breaker box to the switch location Connect the fan High speed Black to the Black wire of the t...

Page 8: ...o the bottom left terminal of the High Low switch LOW Connect the incoming common wire usually White to the wire from the common lead White of the motor Connect the incoming ground wire usually bare copper to the grounding screws on each switch 4 5 and to the ground wire connected to the ground screw in the fan wiring box marked with a ground symbol Install the switches in the UL listed double gan...

Page 9: ...fter 10 20 Minutes Insufficient intake or exhaust Net Free Air Open more doors and windows or increase the amount of ventilation in the attic Unit is Noisy Moving the fan further into the attic will reduce the apparent noise Make sure all screws and bolts are tightened Verify Exhaust NFA Inadequate NFA will result in the unit working harder and making more noise Not Enough Airflow Verify NFA intak...

Page 10: ...cement and return to you of any part or component not covered by this warranty including parts or components damaged by you The company reserves the right to demand and receive written evidence of the date of purchase before undertaking its obligations under this warranty The right to demand and receive written evidence of date of purchase extends to all licensed dealers of Ventamatic Ltd products...

Reviews: