6
Charge
Indication lamp
Operating indication
Standby
During charging
Charging completed
Input voltage error
Input current error
Temperature error
Foreign substance
detection
Lights up green
Lights up orange
Lights up green
Alternately flashes green/red
Alternately flashes orange/red
Lights up red
Flashes red
Error indication
7
When a trouble occurs
8
Specifications
The product does not
enter a standby state.
(The green lamp does not
light up.)
The product does not
charge.
(The orange lamp does
not light up.)
- Use an AC adaptor for USB output.
- Check connection between this machine and the
cable, and connection between the cable and the
AC adaptor.
- Insert the connector completely.
- Confirm that the device to be charged is compatible
with Qi.
- Confirm the Instruction Manual of the device to be
charged.
- Adjust the position to place the device to be charged.
- Remove the case of the device to be charged.
- Confirm that the device to be charged is not
completely charged.
Charging is stopped in
the process.
(The red lamp lights up.)
- Remove the case of the device to be charged.
- Remove a foreign substance between the main
body and the device to be charged.
- Cool down the main body and the device to be
charged and start charging again.
Qi Version 1.2.4
Max. 15W
DC5V/2A
DC12V/2A Quick Charge
TM
2.0/3.0
USB Micro-B
Diameter 95mm × Thickness 9mm
Approx. 57g
Applicable standard
Output
Input
Input terminal
Outside dimensions
Mass
0
〜
35
℃
Operating
temperature
Power cable (USB-A - USB Micro-B) Approx. 90cm
Protective sheet
Instruction Manual (with a warranty certificate)
Included items
* In order to improve the product, specifications and external appearance may be
subject to change without prior notice.
* Qi is a registered trademark of the Wireless Power Consortium.
* Quick Charge is a trademark of Qualcomm Incorporated.
* The described names, logos and service marks are registered trademarks or
trademarks of MAXELL or other companies.
* When the indication lamp flashes green/red or orange/red, there is an error with
the input power. Change the USB output AC adaptor connected.
* When the indication lamp lights up red, the charging part has heated up and
stops charging. Move the product to a low temperature place or leave the product
as it is for a while in order to cool down the charging part.
* When the indication lamp flashes red, a metallic foreign substance is detected
between the device to be charged and the main body. Remove any foreign
substance such as a coin or clip. If the device to be charged is not compatible
with Qi, it may be regarded as a foreign substance.
* Even after charging is completed, the indication lamp on the main body may not
change to green depending on the type of device to be charged. Check the
indication on the device to be charged for its charging state.
* Even after charging is completed, some devices to be charged may not indicate
that the battery power is 100%.
* When the indication lamp lights up green, the product is in a standby state. The
standby power is consumed even in a standby state, therefore, disconnect the
cable if the product will not be used for a long time.
1. Place the device to be charged on the center of the main body.
2. When the device is placed on the center of the main body, the indication lamp
on the main body changes from green to orange and starts charging.
At the time it starts charging, also confirm the indication on the device to be
charged.
* If the indication lamp does not change to orange, or charge indication on the
device does not appear, adjust the position of the device.
3. When charging is completed, the indication lamp on the main body changes
from orange to green. Confirm the indication also on the device to be charged.
When charging is completed, remove the device to be charged from the main
body.
Indication lamp
Maxell, Ltd.