STORAGE
When you are finished using the generator, you must:
Disconnect all loads
Shut off fuel supply
Disconnect spark plug and battery
Store the generator properly
Plan on operating the engine regularly unless the generator is
prepared for long term storage.
DISCONNECT LOADS AND TURN OFF THE FUEL SUPPLY
When you are finished using the generator, disconnect all loads and turn
off fuel supply.
Make sure all devices that were connected to the generator
’
s
outlets have been disconnected.
Check to be sure line shut-off valve is in OFF
position.
COOL THE ENGINE BEFORE STORING
Let engine cool for at least five minutes before storing. A hot engine can
be a fire hazard.
CHOOSE A STORAGE LOCATION
Store the generator in a location that is clean, dry, away from sources of
heat, open flames, sparks, or pilot lights and is not subject to extreme high
or low temperatures. Residual fuel in the tank could ignite even if the
generator
’
s fuel tank is empty.
Note:
Do not store with battery charger always connected.
Batteries that are over-charged can boil dry and produce
excessive amounts of hydrogen and explosive gas.