background image

 

6

Connect to PC 

The reader can be connected to PC by RS232 or LAN.   

RS232 

The reader has a DB9 RS232 port which is usually connected to PC for communication. Directly connect 

RS232 of reader to the COM port of PC with DB9 Female cable. The inner connecting relationship is 

illustrated below: 

 

4.1

 

Connect to Controller 

The reader can be connected to controller by RS485 or WIEGAND. 

RS485 

The reader has a RS485 connector, which is usually used for connection between reader and controller. 

It can be intergrated to RS485 network or connected to PC through a converter. RS485 should be a twist 

masked cable, with 1000m of reliable communication distance. RS485 cable consists of two difference 

signal wires: (

A+

) and RS485B-(

B-

).  

Wiegand 

The reader has a Wiegand connector, which is usually used for connection between reader and controller. 

Wiegand should be a twist masked cable, within 10m of reliable communication distance. Wiegand cable 

consists of three signal wires: Data0(

D0

), Data1(

D1

) and Ground(

GND

). Please make sure the good 

connection to the ground. 

4.2

 

Connect to Trigger & GPIO 

The reader can response outer trigger. It can realize input/output by GPIO, too. 

Trigger 

In Trigger connection, you should touch 

IN

 to 

GND

 by outer trigger. For example, you may add a relay to 

realize a trigger from ground sensor or key-pressing. The suggested connecting method is illustrated 

below: 

Summary of Contents for Q-1000

Page 1: ...r R D Dept This User s Guide is for salesperson installing and technical support person of RFID Reader in order to make them understand the installing and testing of our readers clearly Before operati...

Page 2: ...NSTALLATION CONNECTION 3 2 1 INSTALLATION POWER SUPPLY 3 2 2 CONNECT TO PC CONTROLLER 3 3 WORKING MODE 4 3 1 MASTER SLAVE MODE 4 3 2 TRIGGER AUTOMATIC MODE 4 4 COMMUNICATION PORT 5 CONNECT TO PC 6 4 1...

Page 3: ...k Attendance Check on work attendance HR management Miner Miner management insurance EduToHome Students management between school and home 1 1 Product Performance Item Parameters Performance Reader Ta...

Page 4: ...m for Wiegand 100m for LAN and 1 0KM for RS485 Exceeding the above distances is not suggested The power input of this reader is 12V DC An AC to DC adaptor is offered Plug the adaptor into DC connector...

Page 5: ...ader will stay idle We provide SDK software package for reader This kit package includes Serial Port Communication Protocol API functions set and Demo sample program API functions set and Demo sample...

Page 6: ...rts of the reader include Port Name Port Type Port Qty Application TRIGGER IN 1 Pcs Connect Reader to outer Relay RS 485 A B 1 Group Connect Reader to Controller WIEGAND D0 D1 1 Group Connect Reader t...

Page 7: ...st masked cable with 1000m of reliable communication distance RS485 cable consists of two difference signal wires RS485A A and RS485B B Wiegand The reader has a Wiegand connector which is usually used...

Page 8: ...not give GPIO user may ask us to customize them if needed In GPIO connection you should connect GPO Output and GPI Input to the outer equipment The GPO could be connected to outer equipment eg Relay t...

Page 9: ...erence to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television rece...

Reviews: