1.3 PC4164-NB Specifications
•
One PC4164-NB receiver may be installed per PC4010/4020 system
•
Nominal current draw of 80mA
•
Frequency: 434 MHz
•
Receives signals from up to 56 wireless zones on a PC4010 v3.0 and later, and
up to 64 wireless zones on a PC4020 v3.0 and later
•
Antenna - diversity design for enhanced performance
•
Programmable supervisory window, 01:00 to 23:59
•
Location
- can be wired up to 750 ft. / 230 m from the main panel with 22 gauge wire
- connects to Combus
- for longer wire runs, thicker gauge wire must be used.
1.4 Wireless Devices
Please refer to the Installation Instruction sheets of the following devices for more
information.
The PC4164-NB v2.0 can receive signals from the following devices:
This unit is listed as a single or multiple station smoke detector accessory.
•
WLS904-NB Motion Detector
•
WLS907-NB Universal Transmitter
•
WLS909-NB Wireless Key (up to 16)
Batteries
The wireless devices are designed to use Eveready Alkaline Energizer batteries
only.
NOTE
: Do not use other brands of batteries. Using any other brand voids any approvals
and may affect the system operation.