Maxsys PC4164-NB Manual Download Page 1

Table of Contents

Section 1: Introduction

3

1.1

Before You Begin ......................................................................................... 3

1.2

How to Use This Manual ........................................................................... 4

1.3

PC4164-NB Specifications .......................................................................... 5

1.4

Wireless Devices .......................................................................................... 5

Section 2: Getting Started

6

2.1

Unpack the PC4164-NB .............................................................................. 6

2.2

Find a Mounting Location for the PC4164-NB ....................................... 6

2.3

Connecting the PC4164-NB ....................................................................... 7

2.4

Enroll the PC4164-NB ................................................................................. 8

Section 3: Enroll & Program Wireless Devices

9

3.1

A Note about Electronic Serial Numbers (ESN) ..................................... 9

3.2

Enroll Wireless Devices using Zones (WLS904-NB and WLS907-NB) 9

3.3

Enroll and Program Wireless Keys (WLS909-NB) ............................... 10

Section 4: Testing & Mounting Devices

12

4.1

Test the Placement of WLS904-NB and WLS907-NB Devices ............ 12

4.2

Test WLS909-NB Reception ..................................................................... 13

4.3

Mount the PC4164-NB and Wireless Devices ....................................... 13

Section 5: Deleting & Replacing Devices

14

5.1

Replacing Devices ..................................................................................... 14

5.2

Deleting Devices ........................................................................................ 15

5.3

Erasing Device Serial Numbers .............................................................. 15

Section 6: Additional Programming Notes

16

6.1

Device Supervision ................................................................................... 16

6.2

Trouble Conditions .................................................................................... 17

Section 7: Troubleshooting

19

Programming Worksheets

20

Index

23

Limited Warranty

24

firealarmresources.com

Summary of Contents for PC4164-NB

Page 1: ...l Wireless Devices using Zones WLS904 NB and WLS907 NB 9 3 3 Enroll and Program Wireless Keys WLS909 NB 10 Section 4 Testing Mounting Devices 12 4 1 Test the Placement of WLS904 NB and WLS907 NB Devic...

Page 2: ...are a part of this system may not properly alert occupants of a fire for a number of reasons some of which follow The smoke detectors may have been improperly installed or positioned Smoke may not be...

Page 3: ...Begin This manual describes how to install program and maintain the PC4164 NB on a PC4010 4020 Security System You should have completed the following steps in your PC4010 4020 installation before yo...

Page 4: ...7 and 8 For help with troubleshooting see Section 9 Record the zone or slot and serial numbers of all wireless devices and other programming in the Programming Worksheets section at the end of the man...

Page 5: ...for longer wire runs thicker gauge wire must be used 1 4 Wireless Devices Please refer to the Installation Instruction sheets of the following devices for more information The PC4164 NB v2 0 can recei...

Page 6: ...ntral to the proposed placement of all wireless devices As high as possible Far from sources of interference including electrical noise such as computers televisions and electric motors in appliances...

Page 7: ...the PC4164 NB The PC4164 NB is connected to the control panel via the Combus CAUTION Remove all power from the panel while connecting modules to the Combus Wire the PC4164 NB to the Combus of the PC40...

Page 8: ...e steps to enroll your PC4164 NB module 1 At a PC4010 4020 system LCD keypad enter 8 Installer s code to go to the Installer s Programming section 2 Enter Ref 0200 to go to the Enroll Module section 3...

Page 9: ...unting location to make sure that it can communicate properly with the PC4164 NB Test the device 2 3 times See Section 4 1 for more information 1 At a system LCD keypad enter 8 Installer s code 2 Ente...

Page 10: ...s a 5 digit number enter a 0 and then the 5 digit number 4 The display will show Enroll Device WKEY XX where XX the Wkey slot to which the WLS909 NB is assigned 01 to 16 5 Record the serial number and...

Page 11: ...y 07 Arm Interior 01 Stay Arm 08 15 7 Command Outputs 1 8 02 Away Arm 16 Fire Alarm 03 No Entry Arm 17 Auxiliary Alarm 04 Chime On Off 18 Panic Alarm 05 System Test 19 Disarm Off 06 Quick Exit NOTE If...

Page 12: ...ler s code 3 Enter Ref 001303 to go to the Device Test section 4 Enter 00 to have test results sounded on the keypad buzzers only Enter 01 to have test results sounded by the system bells as well as t...

Page 13: ...oints in the installation you will need to move the PC4164 NB receiver Moving the PC4164 NB higher will usually improve the reception If you move the PC4164 NB repeat the tests described in sections 4...

Page 14: ...ction The LCD keypad will display Serial and either Zone XXX Wkey XX or HHK XX 3 Use the keys to scroll to the device to be deleted then press The LCD keypad will display With Device Serial 4 Enter th...

Page 15: ...he next device enrolled will be placed in zone number 020 If you enroll a device of the same class as the one deleted See Replacing Devices above it will be placed in the old device s slot Make sure y...

Page 16: ...issing causing a Device Fault The next supervisory transmission that the PC4164 NB receives from the missing zone will restore communication with that zone and restore the Zone Supervisory Fault The D...

Page 17: ...uble will be transmitted The low battery alarm and restore codes will only be reported once per armed period The Low Battery Restore transmission is not delayed The default transmission delay is 7 day...

Page 18: ...ransmissions The panel will transmit the General System Trouble reporting code The default setting for this option is OFF To enable warning of this trouble condition 1 At a LCD keypad enter 8 Installe...

Page 19: ...s entered when the device was enrolled Verify that the device is in range of the PC4164 NB Try testing the device in the same room as the receiver Confirm that the PC4164 NB is properly connected to t...

Page 20: ...l_____l l_____l_____l_____l 30 l_____l_____l_____l_____l_____l_____l l_____l_____l_____l 31 l_____l_____l_____l_____l_____l_____l l_____l_____l_____l 32 l_____l_____l_____l_____l_____l_____l System PC...

Page 21: ..._l l_________l 05 l_____l_____l l_________l l_____l_____l l_________l l_____l_____l l_________l l_____l_____l l_________l 06 l_____l_____l l_________l l_____l_____l l_________l l_____l_____l l________...

Page 22: ..._____l_____l_____l l________l l_____l_____l_____l l________l l_____l_____l_____l l________l l_____l_____l_____l l________l l_____l_____l_____l l________l l_____l_____l_____l l________l l_____l_____l__...

Page 23: ...6 Low battery devices 17 M Motion detector test 12 Mount devices 13 PC4164 NB 13 N Number serial 9 slot 10 zone 9 Numbers reference 4 P Partition programming for buttons 11 Placement PC4164 NB 6 test...

Page 24: ...ll be limited to a replace ment of the product as the exclusive remedy for breach of warranty Under no circumstances shall Digital Security Controls Ltd be liable for any spe cial incidental or conseq...

Page 25: ...ecurity Products TM 1999 Digital Security Controls Ltd 1645 Flint Road Downsview Ontario Canada M3J 2J6 416 665 8460 1 800 387 3630 www dscgrp com Printed in Canada 29004102 R001 firealarmresources co...

Page 26: ...formation on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully read PC4164 NB v2 0 Installatio...

Page 27: ...een type tested and found to comply with the limits for Class B device in accordance with the specifications in Subpart B of Part 15 of FCC Rules which are designed to provide reasonable protection ag...

Reviews: