MaxStream XCite Manual Download Page 6

XCite™ OEM RF Module – Product Manual v1.1 

 

The interface signals are available through the 11-pin header. All pins operate on VCC CMOS 
levels. Five signals commonly used in applications are: 

 

DI (pin 4 – Data In) 

 

DO (pin 3 – Data Out) 

 

VCC (pin 10 – Power) 

 

GND (pin 11 – Ground) 

 

DO2-

 (pin 1 – Clear-to-Send) 

The remaining six pins may be used for additional functionality. Go to the “XCite Advanced 
Programming & Configuration” manual for more detailed information about Pin Signals. 

Application Circuit 

Figure 2.

 

Application Circuit – connection to host processor 

 

 

 

 

 

 

 

Mechanical Drawings 

Figure 3.

 

Mechanical Drawings 

(measured in inches)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

© 2004 MaxStream, Inc., Confidential and Proprietary 

6

Summary of Contents for XCite

Page 1: ...mponents RF Module Configuration Appendices Product Manual v1 1 For XCite OEM RF Module Part Numbers XC09 009 XC09 038 355 South 520 West Suite 180 Lindon UT 84042 Phone 801 765 9885 Fax 801 765 9895...

Page 2: ...this manual may be transmitted or reproduced in any form or by any means without the written permission of MaxStream Inc XCite is a trademark of MaxStream Inc Technical Support Phone 801 765 9885 Live...

Page 3: ...umber XIB R 10 RS 232 485 Interface Board Components Features 11 RF Module Configuration 12 Command Parameter Types 12 XCite Commands Parameter Reference 13 Configuration Software 15 X CTU Software 15...

Page 4: ...the web www maxstream net helpdesk Features Long Range Indoor Urban Range Up to 300 90 m Outdoor RF Line of sight Range Up to 1000 300 m w 2 1 dB dipole antenna Receiver Sensitivity 108 dBm 9600 Baud...

Page 5: ...rial data entering the XCite Module from the host 5 DI2 I low Request to Send 6 I low Reset Module Parameters 7 DO3 O high Receive RX LED low Asserted during transmission 8 PWR O high PWR Indicates po...

Page 6: ...C pin 10 Power GND pin 11 Ground DO2 pin 1 Clear to Send The remaining six pins may be used for additional functionality Go to the XCite Advanced Programming Configuration manual for more detailed inf...

Page 7: ...and B are associated with Figure 4 Table 3 DC Characteristics Vcc 2 85 to 5 50V Symbol Parameter Condition Min Typical Max Units VIL Input Low Voltage All input signals 0 5 0 3 Vcc V VIH Input High Vo...

Page 8: ...figure below Figure 6 Data Flow in a UART interfaced environment Low asserted signals distinguished with horizontal line over signal name RS 232 and RS 485 422 Data Flow The XCite Module can enable a...

Page 9: ...ver the air Selectable using BI Number of Bits Parameter Start and stop bits of the UART signal are not transmitted over the air but are regenerated by the receiving module The MaxStream OEM RF Module...

Page 10: ...dipole antenna A09 HASM 675 Serial Loopback Adapter 1 Connects to the female RS 232 DB 9 serial connector of the XCite Module and can be used to configure the radio modem to function as a repeater for...

Page 11: ...Power Connector Center positive 5 5 2 1mm Power can also be supplied through Pin 9 of the DB 9 Connector 10a DIP Switch Figure 10 Back View The DIP Switch configures the XCite OEM RF Module to operat...

Page 12: ...y entering AT Command Mode and sending commands to the module AT Commands are listed in Table 5 AT Commands can be modified using the any of the following means X CTU Software Modem Configuration tab...

Page 13: ...the RF packet Only radio modems having matching addresses can communicate with each other Range 0 0xFFFF Networking 2 0 HP Channel Select Hopping or Single Frequency channel on which the radio modem...

Page 14: ...w control is on by default Range 0 1 0 disable 1 enabled Serial Interfacing 1 0 HT Time before Wake up Initializer Set time period of inactivity no serial or RF data is sent or received before a Wake...

Page 15: ...tware folder of the MaxStream CD and also under the Downloads section of the following web page http www maxstream net helpdesk Using X CTU software In order to use the X CTU software a module assembl...

Page 16: ...ing Requirements Label Warning WARNING The Original Equipment Manufacturer OEM must ensure that FCC labeling requirements are met This includes a clearly visible label on the outside of the final prod...

Page 17: ...ss B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates...

Page 18: ...1dBi Fixed Mobile A09 HBMM P5I 1 2 wave antenna 2 1dBi Fixed Mobile A09 QBMM P5I 1 4 wave antenna 1 9 dBi Fixed Mobile 1 4 wave integrated wire antenna 1 9 dBi Fixed Mobile FCC approved antennas not...

Page 19: ...t Channel Capacity Hopping Mode 7 hop sequences share 25 frequencies or Single Channel Mode 25 single frequency channels Serial Data Interface CMOS I O Data Rate Software selectable 1200 57600 bps Pow...

Page 20: ...ARRANTIES EXPRESS OR IMPLIED AND MAXSTREAM SPECIFICALLY DISCLAIMS ALL WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL MAXSTREAM ITS SUPPLIERS OR LICENSORS BE LIABLE...

Page 21: ...hnical support is included with every MaxStream Radio Modem sold Please use the following resources for additional support Documentation www maxstream net helpdesk Technical Support Phone 866 765 9885...

Reviews: