16
into Idle Mode to listen for valid data packets and de-asserts when the modem returns to Sleep
Mode.
The modem remains in Sleep Mode for a user-defined period of time ranging from 0.5 seconds to
16 seconds (SM Parameters 3 through 8). After this interval of time, the modem returns to Idle
Mode and listens for a valid data packet for 100 ms. If the modem does not detect valid data (on
any frequency), the modem returns to Sleep Mode. If valid data is detected, the modem transi-
tions into Receive Mode and receives the incoming packets. The modem then returns to Sleep
Mode after a Period of inactivity that is determined by ST "Time before Sleep" Parameter.
The modem can also be configured to Wake-up from cyclic sleep when the SLEEP pin is de-
asserted (low). To configure a modem to operate in this manner, PW (Pin Wake-up) Command
must be issued. Once the Sleep pin is de-asserted, the modem is forced into Idle Mode and can
begin transmitting or receiving data. It remains active until no data is detected for the period of
time specified by the ST parameter, at which point it resumes its low-power cyclic state.
Note: The cyclic interval time defined by SM (Sleep Mode) Command must be shorter than the interval
time defined by LH ("Wake-up Initializer Timer") Command. For example: If SM=4 (Cyclic 1.0 second
sleep), the LH Parameter should equal 0xB ("1.1" seconds). With these parameters set, there is no risk
of the receiving modem being asleep for the duration of the wake-up initializer transmission. The fol-
lowing section "Cyclic Scanning" explains in further detail the relationship between "Cyclic Sleep" and
"Wake-up Initializer Timer"
Cyclic Scanning. Each RF transmission consists of a wake-up initializer and payload data. The
wake-up initializer contains initialization information and all receiving modems must Wake-up dur-
ing the wake-up initializer portion of data transmission in order to synchronize with the transmitter
and receive the data.
The cyclic interval time defined by the SM (Sleep Mode) command must be shorter than the interval
time defined by LH (Wake-up Initializer Timer) command.
Figure
3
‐
06. Correct
Configuration
(LH
>
SM):
The
length
of
the
wake
‐
up
initializer
exceeds
the
time
interval
of
Cyclic
Sleep.
The
receiver
is
guaranteed
to
detect
the
wake
‐
up
initializer
and
receive
the
accompanying
payload
data.
17 / 40