Servo Test Mode Operation & Display

Servo Mode can provide the Linear, Speed and the Deadband test.
The servo load current should be lower than 500mA

   No Battery

ACT 

SERVO

 POWER

          SETUP

LINEAR    

SPEED

DEADBAND

Digital

 Servo

Speed:    S/60

°

Digital Servo
Speed:

0.12

S/60

°

START/ENTER

ESC/STOP

Connect the Servo to the 

Data port 

on the right side of X6-Plus.

Then press "ENTER" to get the SERVO Mode

LINEAR

    SPEED

DEADBAND

Analog

  Servo

Pulse:    uS

Analog  Servo
Pulse:

1499

uS

START/ENTER

START/ENTER

ESC/STOP

START/ENTER

ESC/STOP

START/ENTER

START/ENTER

START/ENTER

LINEAR    SPEED

DEADBAND

Analog

  Servo

Deadband:  uS

Analog  Servo
Deadband: 

2

uS

START/ENTER

START/ENTER

START/ENTER

ESC/STOP

ESC/STOP

Linearity Test

1. Choose servo property(Analog or Digital)
2. Hold the DEC to scroll through the pulse width to the lowest point. Hold the INC to scroll through the pulse width to
the highest point.
3. Check the servo running smooth or not to get the information of linearity, and search the shake point of damaged
servo.

Speed Test

Every servo has its own responding speed. and after a period of using, the speed will change also. By testing the speed,
we can get information of actual speed and select the servos with similar speed (e.g. CCPM helicopter)
1. Choose servo property(Analog or Digital)
2. Press "ENTER" to run the speed test program. X6-Plus will output 5V DC to turn the servo left and right automaticlly.
Servo speed is displayed on the LCD (Base on 5V DC & 60° turn )
3. Press "STOP" to exit the function.

Dead band Test

Dead band Test can give the feedback of servo sensitivity. Generally, the dead band of normal servos shall be 1uS.
However, because of the precision of servo and assembly, the actual dead band will be different. By testing the dead
band, the actual size of dead band can be defined, which can help you select servos with the same sized dead band.
1. Choose servo property(Analog or Digital)
2. The begining dead band is 0uS. the servo is at the middle position. Press DEC or INC to set the value(1uS/Step),  until
the servo move slightly & regularly itself.  The value is the dead band.
NOTE: The servo is at the middle position when the dead band value 0uS is setted.

Summary of Contents for X6-Plus

Page 1: ...Charge 5 B Li Po Li Ion Li Mn LiFePO4 Discharge 6 C Li Po Li Ion Li Mn Storage 7 D Li Po Li Ion Li Mn LiFePO4 Balance 8 E Li Po Li Ion Li Mn LiFe Cycle 9 NiMH NiCD Pb CHG or DHG Operation Display 10...

Page 2: ...harge balance storage discharge charge discharge cycle and battery monitor NiMH NiCd Pb batteries charge discharge charge discharge cycle 7 Perfect protection The X6 Plus has protection for reversed p...

Page 3: ...s manual PC monitor software Battery Analyzer software inside Optional parts Multi connector output cable Multi Battery Charging Adapter 2S 3S LCD display abbreviations ACT Activation mode CHG CH Cha...

Page 4: ...ed with your battery to determine the correct capacity setting It is very important to get this right as the charger uses the capacity setting to determine nominal charge rate amperage capacity protec...

Page 5: ...ithin CHG DHG STO BAL CYCLE CHG Charge mode DHG Discharge mode STO Storage mode BAL Balance mode CYCLE Discharge Charge cycle mode Press DEC INC Scroll through the setting of charging speed within Slo...

Page 6: ...ss DEC INC Scroll through the setting within CHG DHG STO BAL CYCLE Press DEC INC Scroll through the setting of Discharge Cut off Voltage 0 05V Step Be Sure the cut off voltage is properly configured f...

Page 7: ...s X6 Plus will set the cell numbers automatically according to the Balance Connector connected Press DEC INC Scroll through the setting within CHG DHG STO BAL CYCLE Press DEC INC Scroll through the se...

Page 8: ...h the setting within LiFe LiPo LiIon LiMn Be Sure the charger is properly configured for the correct battery type Press DEC INC Scroll through the setting of cell numbers X6 Plus will set the cell num...

Page 9: ...ss DEC INC Scroll through the setting of Cycle order DHG CHG or CHG DHG Press DEC INC Scroll through the setting of Cycle count Input number of cycles desired Press DEC INC Scroll through the setting...

Page 10: ...ENTER ESC STOP NiMH Fast CHG 8S 2500mAH 1 5A START ENTER CC 10 90V 2 00A 20 56mAH 0 02 CHG END 11 62V 32 1856mAH 0 56 ESC STOP NiMH Fast CHG 8S 2500mAH 2 0A START ENTER ESC STOP Starting charge START...

Page 11: ...1V Type NiMH 8S START ENTER ESC STOP START ENTER ESC STOP NiMH 8S CYCLE CHG DHG 1 1 1A DH 11 00V 1 50A 20 880mAH 0 36 Wait CHG 300S NiMH 8S CYC 2 NiMH 8S CYCLE CHG DHG 3 1 5A START ENTER ESC STOP NiMH...

Page 12: ...the setting of charging current 0 1A Step Be Sure the charging current is proper for battery pack Starting charge START ENTER CC 10 90V 0 98A 20 41mAH 0 02 Charging Status screen the stage of the cha...

Page 13: ...point of damaged servo Speed Test Every servo has its own responding speed and after a period of using the speed will change also By testing the speed we can get information of actual speed and select...

Page 14: ...he output socket before you choose the POWER Mode START ENTER ESC STOP Power Mode can provide 3 0 30V adjustable DC to meet your requirement DEC Output Set 30 0V OUT 30 00V 0 01A INC Press DEC INC to...

Page 15: ...TUP function Press DEC INC Scroll through the setting within ON OFF Press DEC INC Scroll through the setting within ON OFF Temperature Cut Off value range 30 60 if any battery you are charging or disc...

Page 16: ...s always free on our website Pls download it yourself 5 Shipping cost a If the product is covered under warranty Please contact the Maxpro s Distributor in near your location for the warranty service...

Reviews: