SUGGESTED PREVENTATIVE MAINTENANCE

 

 

FOR

 

 

 

FOR AIR DRIVEN AIR AMPLIFIERS

 

 

 

The suggested maintenance schedule is intended only as a guideline.  The operating conditions of the 

amplifier, such as air drive pressure, air supply pressure, air outlet pressure, air cleanliness and actual 

running time at pressure, combine for an almost infinite range of variable conditions and 

all 

directly 

relate to the life of the amplifier and it’s components.  Even the external environment around the 

amplifier, such as dust and heat can affect the service life. 

 

The following suggestions are based on average operating conditions and a 50% to 60% run time 

factor for the amplifier.  These times could be shorter or longer based on operating conditions listed 

above 

 

EVERY 3 MONTHS

 

Remove spool, remove spool O-Rings and clean spool.  Place New O-Rings on spool and apply a 

 

thin coat of grease

*

 to the O-Rings and bore of the spool sleeve housing.  Insert spool 

 

gently back in spool sleeve, by working it in and not forcing it straight in. 

 

Remove and check pilot tappets and the bonded O-Ring.  Make sure the O-Ring is still attached. 

 

If the tappet is damaged or the O-Ring is loose, replace the tappet. 

 

Inspect muffler to make sure it is not coated with dirt and/or oil.  Replace if necessary. 

 

EVERY 6 MONTHS

 

 

Rebuild the Spool, Air and Gas sections and clean and inspect the check valve sections as well as all 

major components for scratches or damage. 

 

EVERY 12 MONTHS

 

Rebuild and clean the entire amplifier 

 

* Recommended grease is a high temperature type, Kluber Lube, Polylube GA352P

 