
1
1921 Slauson
A
ve. Santa Fe Springs, CA. 90670 (800) 227-41
16 F
AX (888) 771-7713
32
TE SERIES ELECTRICAL VALUES
SYSTEM DIAGRAMS
Solenoid Switch
12V
24V
Coil Resistance:
5.4
Ω
@70ºF. ±15%
20.1
Ω
@70ºF. ±15%
Ampere:
2.2A
1.2A
Coil terminal torque:
10-15 lb-in
max.
Contact terminal torque:
30-35
lb-in
max.
Solenoid Valves (A, S1, & S2)
Coil Resistance:
6.6
Ω
@ 70ºF. ±15% 26.7
Ω
@ 70ºF. ±15%
Ampere:
1.8A
0.9A
Coil terminal torque:
15-45
lb-in
max.
Valve cartridge torque:
25-30
lb-ft
max.
Coil nut torque:
15-45
lb-in
Solenoid Lock Valve
Coil Resistance:
8.0
Ω
@ 70ºF. ±15% 30
Ω
@ 70ºF. ±15%
Ampere:
1.5A
0.8A
Coil terminal torque:
3-4.5
lb-ft
max.
Valve cartridge torque:
18.5-22 lb-ft
max.
Ground Cable
Cap Screw Torque:
24
lb-ft
max.
TABLE 32-1