Conventional Mode Operation   

Your Maxon SM5402 Radio may be programmed to operate in Conventional modes. 
Conventional mode may or may not require a Conventional repeater System. Radio to 
radio communications can also be accomplished in Conventional operation. How the 
Conventional mode is programmed is determined by your Dealer.   

 

Transmitting  

1. Rotate the On / Off - Volume control clockwise to turn the power on.   
2. Adjust On / Off - Volume control further clockwise to increase the volume level.   

Rotate counter clockwise to decrease volume level. 

3. Select the desired Conventional System and Group channel using the Up / Down buttons 

located on the front panel of the radio.   

4. In a Conventional System it is necessary to monitor the channel for activity before a 

transmission. Monitor the channel by pressing the OPT (option) button located on the front 
panel and selecting monitor, once selected pressing OPT button once will begin monitor 
function, pressing OPT a second time will turn off monitor function. Monitoring of the channel 
can also be accomplished by observing the LED indicator for a solid yellow color. If solid yellow 
is observed, you must wait for the indication to leave before a transmission can be made.   

5. Press and hold the microphone P-T-T lever on the side of the micro-phone, LED indication will 

glow red, hold the microphone 1 or 2 inches from you mouth, speak clearly and distinctly into 
the microphone area of the front grille.   

6. Release the P-T-T lever as soon as the message is complete and listen for a response. The 

P-T-T lever must be pressed continuously while talking and released to listen.   

 

 

Receiving  

1. Turn power on and set the volume level as previously described.   
2. Select the desired System and System Group channel.   
3. When a message is received, the LED indicator will glow solid yellow or green depending 

  if CTCSS tone or DCS has been programmed.   

4. Respond to message by pressing the P-T-T lever on the side of the microphone. Press the 

P-T-T continuously while talking and release to listen.   

 

If scanning modes are enabled be sure to respond before scanning resumes, if you do not, 
another call may be received and the selected channel may have to be changed. Scanning is 
indicated by the scan mode icons. Refer to 

Conventional Scanning

  for more descriptive 

information.  

Summary of Contents for SM5402

Page 1: ...SM5402 Operating Instructions...

Page 2: ...and 800 MHz frequencies personal two way communication devices including the popular FRS Family Radio Service and GMRS radios and a variety of wireless communication products two way voice messaging h...

Page 3: ...authorized by the manufacturer for use with this radio ALWAYS use Maxon authorized accessories Use of unauthorized accessories can cause the FCC RF exposure compliance requirements to be exceeded DO n...

Page 4: ...UTION DO not operate the radio near electrical blasting caps or in an explosive atmosphere CAUTION DO not operate the transmitter of any radio unless all RF connectors are secure and any open connecto...

Page 5: ...ions SM5402 Features z Conventional radio operation z 9 character display with icons z Wideband frequency separation z Programmable output power z Programmable 12 5 25 kHz channel spacing z Multiple f...

Page 6: ...W nominal 10 Modulation Type F3E Audio Power 6W Internal 16W speaker Intermediate Frequencies 45 1MHz First I F 455kHz Second I F Number of Channels 208 Frequency Source PLL Synthesiser Frequency Stab...

Page 7: ...603 95 Protection against ingress of IEC 529 IP54 dust and water Vibration BS2011 Part 2 1Fc IEC 68 2 6 Part 2 1Fd IEC 68 2 34 Robustness Mil Std 810 F ESD 20kV C MIC 15kV Physical Dimensions 175 W x...

Page 8: ...the mounting bracket attach bracket to the surface by using the two large Phillips head screws provided 3 Install the radio unit to the bracket using the black screw knobs located on each side of the...

Page 9: ...n Enables disables optional radio functions also enables scrolling when using the Up Down Selection Buttons 6 Scan Select Button Enables disables Scan functions also toggles between Scan and Priority...

Page 10: ...nventional modes There are only a few differences in their operation and these are detailed as follows Channel Monitoring While on a Trunked System channel monitoring is performed automatically by the...

Page 11: ...oon as the message is complete and listen for a response The P T T lever must be pressed continuously while talking and released to listen Receiving 1 Turn power on and set the volume level as previou...

Page 12: ...ed by observing the LED indicator for a solid yellow color If solid yellow is observed you must wait for the indication to leave before a transmission can be made 5 Press and hold the microphone P T T...

Page 13: ...press and hold will scroll until button is released All System and Group names will be shown in the display and are preprogrammed by your Dealer Mode Button This button will allow you to return to yo...

Page 14: ...nce option is shown in display a second key press of OPT will select option to be used under the OPT button indicated by the SCAN icon If no button press is detected option will not be enabled and rad...

Page 15: ...Public address mode if previously selected as the OPT button function allows the microphone to be used as a public address or intercom feature When activated by a press and release of the OPT button t...

Page 16: ...The majority of LED indications and audible alerts can be enabled or disabled by your Dealer via programming STATUS DESCRIPTION LED COLOR ICON AUDIBLE TONE DISPLAY Normal Power On Ready Red Yellow Gr...

Page 17: ...on Two Beeps Scan Modes Your SM5402 Radio may be programmed for one or more scan modes depending upon your Dealer programming LTR Manual Group Scan To enable LTR manual Group scan enter normal scan by...

Page 18: ...r back on while continuing to hold the scan button Your display will show one of the following EDIT GRP EDIT SYS EDIT PRI Continue holding the scan button until the desired edit function is shown in t...

Page 19: ...n its received scanned Group After transmission is completed the scan delay time will become active allowing for a call to be immediately returned before scanning resumes Talk Back Scan is enabled by...

Page 20: ...adio will go back to the selected channel and resume priority look back operation After a scanned call is received the scan wait time will be active allowing you to pick up the microphone and answer t...

Page 21: ...bers will appear in your radio display will be indicated as P in your display Note The key is normally used to end or hang up an interconnect system Consult your Dealer for exact system operation 3 Pr...

Page 22: ...memory under that key To Recall a Stored number from Memory 1 Press and release the RCL key 2 Press and release the number key from which a number has been stored 3 Press SND to dial the recalled num...

Page 23: ...perating manual may not be copied or reproduced without the express written permission of Maxon Furthermore the purchase of Maxon products shall not be deemed to grant either directly or by implicatio...

Page 24: ...ctionally equivalent reconditioned or new parts or boards Replaced parts accessories batteries or boards are warranted for the balance of the original time period All replaced parts accessories batter...

Page 25: ...AMAGES INCLUDING ANY SPECIAL INCIDENTAL INDIRECT OR CONSEQUENTIAL DAMAGES OR FOR THE LOSS OF PROFIT REVENUE OR DATA ARISING OUT OF THE USE OF OR THE INABILITY TO USE THE PRODUCT This warranty is void...

Reviews: