Electrical Installation
Connections
IDX 56 User Manual
mmag | 2020-04 | rel9398
4-37
4.3.6
USB (X5)
For commissioning only
The USB interface is for commissioning purposes only and must not remain connected during operational
service.
The USB connector X5 is located inside the drive housing behind the sealing cap (Figure 4-20; «A»).
Figure 4-20
USB (X5) – Location
Contaminating the housing’s interior can cause irreversible hardware damage
To access the USB connector you will need to remove the sealing cap. This will break the IP 65 protection
of the drive. It is essential that you protect the drive’s interior against contaminants and foreign particles.
• Wipe off any moisture or dirt before you unscrew the sealing cap.
• Keep the area clean while the sealing cap is removed and cover the access to prevent contamination.
• After you have removed the USB cable, mount the sealing cap and screw tight.
Hot plugging the USB interface can cause irreversible hardware damage
If the USB interface is being hot-plugged (connecting while the power supply is on), the possibly high poten-
tial differences of the two power supplies of drive and PC/Notebook can lead to damaged hardware.
• Avoid potential differences between the power supply of drive and PC/Notebook or, if possible, balance
them.
• Insert the USB connector first, then switch on the power supply of the drive.
USB adapter
The use of a galvanic isolated USB adapter is highly recommend.
Continued on next page.