LIFT CORPORATION
Sht. 7 of 13 DSG#
M-16-04
Rev.
A
Date: 01/13/17
© MAXON Lift Corp. 2017
7.
Disconnect interconnect harness from control switch
cable on the RH column
(FIG. 7-1)
. Then, connect
tee to control switch cable in the RH column and
interconnect harness
(FIG. 7-1)
.
PLASTIC
ENCLOSURE
CONTROL
SWITCH
CABLE
TEE
CONNECTING CABLES TO CONTROL TEE
FIG. 7-1
8.
Connect tee to the control switch cable connector
extending from plastic enclosure
(FIG. 7-1)
.
STREETSIDE SWITCH
ASSEMBLY
RH COLUMN
6.
Route the tee (Kit item) to the
RH column
(FIG. 7-1)
.
9.
Reconnect battery power to the
hydraulic pumps by turning
ON
the
master disconnect switch at the
pump box. Refer to
BMR Operation
Manual
for detailed instructions.
LOCKING RING
CONNECTORS
INTERCONNECT
HARNESS
LOCKING RING
CONNECTORS
NOTE:
Refer to Sheet 4 for important information
about locking ring electrical connectors.
PUMP ASSEMBLY
(REF)
CONTROL
SWITCH CABLE