background image

maxon motor 

Operating Instructions 

1-Q-EC Amplifier DEC 50/5 

5.1.6 “AUX” 

The “AUX” terminal can be used as input or output, depending on the switch 
position. 
The “AUX” terminal is only protected against overvoltage if switch 

S1

 is open. 

 

Switch S1 closed 

Function 

Voltage output 

 

Output voltage 

+5 VDC ± 5 % 

 

Internal resistance 

220 

 

 

Output current, designed for an exter-
nal potentiometer >=10 k

 

 
500 

µ

 

 

 

Switch S1 opened 

Function 

Speed change 

 

Input voltage range 

0 ... +5 V 

 

Input impedance 

33 k

 pull-up resistor at +5 V 

 Continuous 

overvoltage 

protection 

-50 ... +50 V 

 

 

Speed setting with potentiometer 
Speed 1 

Input open or  
input voltage > 4.0 V 

 

Speed setting with potentiometer 
Speed 2 

Set input to Gnd or  
input voltage < 1.0 V 

 
 
 

5.1.7  “Hall sensor 1”, “Hall sensor 2”, “Hall sensor 3” 

Hall sensors are needed for detecting rotor position. 
"Hall sensor" inputs are protected against overvoltage. 
 

 

Input voltage range 

0 ... +5 V 

 Input 

impedance 

15 k

 pull-up resistor at +5 V 

 

Voltage value “low” 

max. 0.8 V 

 

Voltage value “high” 

min. 2.4 V 

 

Continuous overvoltage protection 

-50 ... +50 V 

 
Suitable for Hall effect sensors IC using Schmitt trigger and open collector out-
put. 
 
 
 
 
 
 

5.2 Outputs 

5.2.1 “V

CC

 Hall” 

Powering the Hall sensors. 
 

 

Output voltage 

7 ... 12 VDC 

 

Max. output current 

30 mA (current limited) 

 
 

October 2008 Edition / Doc.No. 544910-06 / subject to change 

maxon motor control 

11

 

Summary of Contents for 1-Q-EC

Page 1: ...ges can be selected or through analogue set value input 0 5 V Maximum current limit adjustable Gain can be adjusted in two stages Adjustable speed ramp Protection against heat overload Blockage protec...

Page 2: ...ectly if the control unit breaks down or if the cables break etc it must be ensured that the drive or the complete apparatus is kept in a safe operating mode Repairs Repairs may only be carried out by...

Page 3: ...Motor connections Motor winding 1 Motor winding 2 Motor winding 3 2 6 Trim potentiometers Speed 1 Speed 2 Ramp Imax gain 2 7 LED indicator Operating indicator green LED Error indicator red LED 2 8 Amb...

Page 4: ...tor 1 Q EC Amplifier DEC 50 5 Operating Instructions 3 Minimum External Wiring for Different Modes of Operation 3 1 Speed control 4 maxon motor control October 2008 Edition Doc No 544910 06 subject to...

Page 5: ...maxon motor Operating Instructions 1 Q EC Amplifier DEC 50 5 3 2 Current control and open loop speed control October 2008 Edition Doc No 544910 06 subject to change maxon motor control 5...

Page 6: ...ntinuous max 5 A acceleration short time max 10 A The required voltage can be calculated as follows Known values Operating torque MB mNm Operating speed nB rpm Nominal motor voltage UN V Motor no load...

Page 7: ...noises the se lected amplification is too high Switch S2 must be set at ON Digital current control 1 Adjust potentiometer P1 Speed 1 to required speed limit Maximum speed in the 500 25 000 rpm range...

Page 8: ...speed see chapter 7 Speed Ranges 5 1 2 Disable Disabling or blocking the power stage If the input is not wired or the applied voltage is greater than 2 4 V the amplifier is activated A speed ramp will...

Page 9: ...the limitations described in chapter 5 1 5 Brake function must be observed or the amplifier may be damaged 5 1 4 Ramp function The ramp function enables the motor speed to have a controlled run up whe...

Page 10: ...ction 50 50 V Max brake current 30 A Delay time approx 12 ms Brake inactive Input open or input voltage 2 4 V Brake active Set input to Gnd or input voltage 0 8 V The maximum permitted brake speed is...

Page 11: ...with potentiometer Speed 1 Input open or input voltage 4 0 V Speed setting with potentiometer Speed 2 Set input to Gnd or input voltage 1 0 V 5 1 7 Hall sensor 1 Hall sensor 2 Hall sensor 3 Hall senso...

Page 12: ...rpm 500 120 000 rpm 125 30 000 rpm 67 15 000 rpm Note Independent of the position of the switches S5 and S6 the maximum speed can with the help of P1 Speed be adjusted only in the range 500 25 000 rp...

Page 13: ...ion of poten tiometers Set value with in ternal potentiome ter P1 Set value with ex ternal potentiome ter With external set value 0 5 V With 2 different speeds Set value with ex ternal potentiome ter...

Page 14: ...sensors not connected or incorrectly connected Intermittent Hall sensor supply lines Excessive interference to Hall sensor supply lines Solution change supply line feeds use shielded cable Faulty Hal...

Page 15: ...esis tive connection Use separate cable Hall sensor cable 30 cm Shielded cable highly recommended Connect shielding on both sides DEC 50 5 side Bottom of housing Motor side Motor housing or with motor...

Page 16: ...Disable Direction Brake Speed AUX V Hall CC Gnd V 10 50V CC Power Ground Motor winding 1 Motor winding 2 Motor winding 3 7 12V 7A 5V 5V 5V P1 Speed 1 P2 Speed 2 Ramp P3 Imax 7 12V 8 Bit Micro Controll...

Reviews: