background image

Operating Instructions                                                                                                           WPOP Series

MaxLite CCT Selectable WallMax™ Open Face

®

• To reduce the risk of death, personal injury or property damage from 

fire, electric shock, falling parts, cuts/abrasions, and other hazards 

read all warnings and instructions included with and on the fixture 
box and all fixture labels.

• Before installing, servicing, or performing routine maintenance upon 

this equipment, follow these general precautions.

• Commercial installation, service and maintenance of luminaires 

should be performed by a qualified licensed electrician.

• For Residential installation: If you are unsure about the installation or

maintenance of the luminaires, consult a qualified licensed electrician 
and check your local electrical code. 

• DO NOT INSTALL DAMAGED PRODUCT!
• This fixture is intended to be connected to a properly installed and 

grounded UL listed junction box.

WARNING:

RISK OF ELECTRICAL SHOCK

• Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply.

• Turn off the power when you perform any maintenance.

• Verify that supply voltage is correct by comparing it with the luminaire label information.

• Make all electrical and grounded connections in accordance with the National Electrical Code 

and any applicable local code requirements.

• All wiring connections should be capped with UL approved wire connectors.

• Do not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or in water.

CAUTION: 

RISK OF INJURY

• Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing 

or performing maintenance.

• Avoid direct eye exposure to the light source while it is on.

• Account for small parts and destroy packing material, as these may be hazardous to children.

CAUTION: 

RISK OF FIRE

• Keep combustible and other materials that can burn away from luminaire and lamp/lens

• MIN 90°C SUPPLY CONDUCTORS.

© Copyright 2021. MaxLite, Inc. All Rights Reserved.
12 York Ave, West Caldwell, NJ 07006   Tel: 800-555-5629   Fax: 973-244-7333   Email: [email protected]

General Safety Information

Page: 1
REV: 11/19/21

Picture is for illustration purposes only. 
Your model may vary.

WPOP Series

Operating Temperature: -30°C to 40°C
Rated Voltage: 120-277 Vac 50/60Hz

Summary of Contents for WPOP Series

Page 1: ...wer when you perform any maintenance Verify that supply voltage is correct by comparing it with the luminaire label information Make all electrical and grounded connections in accordance with the National Electrical Code and any applicable local code requirements All wiring connections should be capped with UL approved wire connectors Do not handle energized fixture when hands are wet when standin...

Page 2: ...e four 4 holes drilled in step 2 4 Drill three 3 holes in locations indicated by E F G Fasten the back plate to the wall with three 3 anchor bolts Reflector Male Connector Female Connector Knockout KO Plug Back Plate Electric Drill 8 32 Screws Main Power Hole H Water proof J Box Reflector Male Connector Female Connector Back Plate A D C B Note Add a bead of exterior grade silicone sealant around t...

Page 3: ...iagram 4 Place the reflector back onto the back plate using the hinge mechanism Next connect the male and female connectors together Finally use a suitable screwdriver to connect the reflector to the back plate to seal the fixture Installation Operation Conduit Mounting Note Add a bead of exterior grade silicone sealant around the perimeter of the wall pack on the wall to inhibit any moisture from...

Page 4: ...West Caldwell NJ 07006 Tel 800 555 5629 Fax 973 244 7333 Email info maxlite com Page 4 REV 11 19 21 2 Plug the USB C sensor into the USB C receptacle on the mounting plate Secure the sensor to the mounting plate with the included screw USB C Mounting Plate USB C Sensor 3 Place the mounting plate into its original position and secure with the two 2 screws removed in step 1 The sensor should fit int...

Page 5: ...pyright 2021 MaxLite Inc All Rights Reserved 12 York Ave West Caldwell NJ 07006 Tel 800 555 5629 Fax 973 244 7333 Email info maxlite com Page 5 REV 11 19 21 Operating Instructions WPOP Series MaxLite CCT Selectable WallMax Open Face Installation Operation Setting Color Temperature Color Settings Left 3000K Middle 4000K Right 5000K Installation Operation Wattage Switch WCS Models Only Wattage Setti...

Page 6: ...FORTH HEREIN IN NO EVENT WILL MAXLITE BE LIABLE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION DAMAGES RESULTING FROM LOSS OF USE PROFITS BUSINESS OR GOODWILL LABOR COSTS REMOVAL OR INSTALLATION COSTS DECREASE IN THE LIGHT OUTPUT OF THE LAMP AND OR DETERIORATION IN THE LAMP S PERFORMANCE WHETHER OR NOT MAXLITE HAS BEEN ADVISED OF THE POSSIBILITY THEREOF UNDER NO C...

Page 7: ...valeur de la tension d alimentation est correcte en la comparant aux informations dans le tableau sur l étiquette du luminaire Réalisez toutes les connexions électriques et de terre en conformité avec le code électrique national et les éventuelles exigences locales applicables du code Toutes les connexions électriques seront terminées avec des connecteurs pour fils approuvés UL Ne manipulez pas le...

Page 8: ...dans les quatre 4 trous percés à l étape 2 4 Percez trois 3 trous dans les endroits marqués E F G Fixez la plaque arrière sur le mur avec trois 3 boulons d ancrage Réflecteur Connecteur mâle Connecteur femelle Bouchon de l entrée de câble KO Plaque arrière Perceuse électrique Vis 8 32 Alimentation principale Trou H Boîtier de jonction imperméable Réflecteur Connecteur mâle Connecteur femelle Plaqu...

Page 9: ...de câblage 4 Place le réflecteur sur la plaque arrière à l aide du mécanisme à charnière Ensuite branchez les connecteurs mâle et femelle Finalement utilisez un tournevis adéquat pour connecter le réflecteur à la plaque arrière pour étanchéiser le luminaire Installation et fonctionnement Installation du conduit Remarque Ajoutez une perle de silicone pour l extérieur autour du périmètre de l appliq...

Page 10: ...d installation USB C Capteur USB C 3 Mettez la plaque d installation dans sa position originale et fixez avec les deux 2 vis enlevées pendant l étape 1 Le capteur doit rentrer dans la lentille en plastique dans la partie inférieure du luminaire 4 Fermez le luminaire et enlevez le couvercle en bronze de la lentille inférieure en plastique Consultez le manuel d instructions pour la programmation du ...

Page 11: ...ation et fonctionnement Réglage de la température de couleur Réglages de la couleur Gauche 3000K Milieu 4000K Droite 5000K Installation et fonctionnement Commutateur de la puissance Modèles WCS uniquement Réglages de la puissance Position 1 Puissance minimale Position 2 Puissance moyenne Position 3 Puissance maximale Mode d emploi Série WPOP Luminaire MaxLite WallMax de type ouvert à TCP sélection...

Page 12: ...EN AUCUN CAS RESPONSABLE DES DOMMAGES PARTICULIERS ACCESSOIRES OU CONSÉCUTIFS Y COMPRIS SANS S Y LIMITER LES DOMMAGES RÉSULTANT DE LA PERTE D UTILISATION DES BÉNÉFICES DES AFFAIRES OU DE LA BONNE VOLONTÉ DES FRAIS DE MAIN D ŒUVRE DES FRAIS DE DÉMÉNAGEMENT OU D INSTALLATION DE LA DIMINUTION DU NIVEAU DE LUMIÈRE DE LA LAMPE ET OU LA DÉTÉRIORATION DES PERFORMANCES DE LA LAMPE QUE MAXLITE SOIT AVERTI ...

Reviews: