SET-UP FOR LINKING PANELS

2. 

Connect by linking to 0-10 input. Violet and grey wires are the 

0-10 input wires

4. 

Continue this for each additional panel up to 30 panels.

11

Grey

Yellow

WALL

DIMMER

Output

0-10

DRIVER

Input

0-10

Violet

Grey

Violet

0-10 Dimmer

0-10

0-10

0-10

WALL

DIMMER

Output

0-10

DRIVER

Grey

Violet

DRIVER

DRIVER

Yellow

Grey

Violet

Grey

Violet

Panel 1

Panel 2

Panel 3

1. 

Select one of the panels to 

be Master Panel.

Master panel will have 0-10 connection

as shown

Summary of Contents for MLFP14DP4535

Page 1: ...t For additional information or assistance please e mail info maxlite com or log on to www maxlite com and click on the Information and Quotes bar INSTALLATION GUIDE FOR 1X4 MLFP14DP4535 MLFP14DP4541...

Page 2: ...4 MOUNTING PANELS IN CEILING 5 SET UP 6 CONNECTING TO AC POWER SOURCE 7 SET UP FOR ON OFF 7 SET UP FOR OPTIONAL IR REMOTE 8 SET UP FOR 0 10V BALLAST DIMMER Building Controls Daylight Harvesting 9 SET...

Page 3: ...hite polycarbonate CAPABILITIES On Off Panels can operate independently or can be daisy chained together to work with standard on off wall switches Dimming Panels are fully dimmable with a standard 0...

Page 4: ...ards Self Driven No additional drivers required Power Connect directly to AC power supply 120V through 277V Contains No Hazardous Material Mercury and UV Free Of LEDs 144 Wattage 45W Nominal Lumens 35...

Page 5: ...olet Yellow Grey Option leads Option Module Mounting Studs Black White Green for connection to AC power source and ground Knock Outs Wire Tie Off Loops Pass Thru Wire Access Face Frame Clip IR Option...

Page 6: ...FEATURES 0 10V Connection on Dimming Control LED Board Leads IR Eye Power Unit 4 Dimming Sensor 0 10V Wire IR Dimmer Controller...

Page 7: ...en seismic hanger 180 to engage ceiling grid frame Model shown for referance only Note Uniform support is vital for safety purposes each panel must have support wire attached Safety Wire Hangers Safet...

Page 8: ...MIN MAX 1 On Off and AC Power Connection 2 IR Remote 3 0 10 Ballast Building Controls Daylight Harvesting 4 Simple Wall Dimming 5 Linking Panels Link up to 30 panels from master using 0 10 wires 6 0...

Page 9: ...ing panels to AC source supply All units must be individually connected to the AC supply 120 277 VAC Black Line White Neutral Green Ground ON OFF operation Line connection to be made to switched lead...

Page 10: ...er control to driver violet yellow grey 2 Position IR Sensor so it can be visible to the Remote Controller 4 Connect IR Sensor Cable to Dimmer controller input labeled IR after cover is re installed 5...

Page 11: ...8 Grey Yellow CENTRAL SYSTEM CONTROLLER Output 0 10 DRIVER Input 0 10 Violet 5 Mount panel feed line through knockouts and operate 4 0 10 connection as shown CENTRAL SYSTEM CONTROLLER 2 Locate the lea...

Page 12: ...rey Yellow WALL DIMMER Output 0 10 DRIVER Input 0 10 Violet Grey Violet 5 Mount panel feed line through knockouts and operate 4 Connect wall dimmer non relay wires to Dimming Controller Wires 0 10 con...

Page 13: ...tional panel up to 30 panels 11 Grey Yellow WALL DIMMER Output 0 10 DRIVER Input 0 10 Violet Grey Violet 0 10 Dimmer 0 10 0 10 0 10 WALL DIMMER Output 0 10 DRIVER Grey Violet DRIVER DRIVER Yellow Grey...

Page 14: ...Lighting Possibilities For additional information or assistance please e mail info maxlite com or log on to www maxlite com and click on the Information and Quotes bar...

Reviews: