MxL7704 EVB Manual
2/28/18
3
Set Up
Powering Up the Evaluation Board
■
Connect P2 (VIN+) and P3 (VIN-) to a 5V power supply. See Note A.
■
Turn on the power supply. The EVB will power up and regulate the outputs as follows:
Channel 1: 3.3V
Channel 2: 1.8V
Channel 3: 1.35V
Channel 4: 1.2V (MXL7704-A-EVB) or 0.85V (MXL7704-X-EVB)
LDO: 3.3V
Monitoring or Testing V
OUT
■
The outputs may be left open or connected to an external load. A low impedance connection will
provide the best load regulation.
Figure 4:
V
IN
Connection
Note A
Note A