IMPORTANT SAFETY PRECAUTIONS

 

READ THESE INSTRUCTIONS CAREFULLY AND RETAIN FOR FUTURE REFERENCE.

 

Failure to observe these instructions will invalidate the 
warranty. This unit may be a source of possible shock. 
Disassemble only to replace lamp. No user-serviceable 
parts inside. Source of possible ignition. 

 

    

WARNING 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY: 

1.

 

Fragile Glass Lamp. Use care when unpacking, handling and installing . 

2.

 

This   appliance  must  be disconnected  from its power source during installation or  service  activities and 
when replacing. 

3.

 

DO NOT use this heater below an installation height of 2.4m with a programmer, timer or any other device 
that switches the heater on automatically. 

4.

 

When mounted on a stand (available separately) DO NOT use this heater in the immediate surroundings of a 
bath, shower or swimming pool. 

5.

 

In order to avoid overheating and potential fire hazard, DO NOT cover the heater. DO NOT cover the heater with 
insulating material or a similar material under any circumstances. 

6.

 

DO NOT install the heater pointing directly downwards and maintain at least 500mm from ceiling or other 
objects. 

7.

 

DO NOT  touch  the  heater when in use. The heater rises to very high temperatures in use. After the heater has 
been switched off let the heater completely cool down before touching it. 

8.

 

DO NOT use the heater if the power cord is damaged. This must be replaced by the manufacturer, its 
service agent or similarly qualified persons in order to avoid a hazard. 

9.

 

DO NOT use the heater to ignite materials. 

10.

 

This heater must only be used for the heating of people outdoors or indoors in an unenclosed space. The 
heater is not to be used by children or persons with reduced physical, sensory or mental capabilities, or lack 
of experience or knowledge, regardless of whether they have been given instruction or are under supervision. 
Children should be kept away and should not be left unsupervised around the unit. 

11.

 

All operators shall only switch on/off the appliance provided that it has been placed or installed in its 
intended normal operating position and they have been given supervision or instruction concerning use of 
the appliance in a safe way and understand the hazards involved. Children shall not plug in, switch on or 
regulate the appliance or perform user maintenance including cleaning. 

12.

 

The  appliance  is  not  to  be  used  by  persons  (including  children)  with  reduced  physical,  sensory  or 
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or 
instruction . 

13.

 

children being supervised not to play with the appliance  

14.

 

Statement: heater is not located immediately below a socket-outlet  

15.

 

The heater must not be used if the glass (or ceramic or similar material) panels are damaged  

16.

 

WARNING: This heater is not equipped with a device to control the room temperature. Do not use this 
heater in small rooms when they are occupied by persons not capable of leaving the room  on their 
own, unless constant supervision is provided.  

17.

 

IMPORTANT: Ensure supply voltage does not exceed 245 volts. 

 

 
 
 

Summary of Contents for RAINBOW 2000

Page 1: ... x 84 7 mm Remote control 2600R only 4 power levels 25 power increments 24 hour time 24x1 hour increments Warm up time 5 10 seconds Useful wavelength range 2 5μm Weight 3kg Warranty 1 Years excludes lamp remote control Protection IP55 Waste electrical productsshould not be disposed of with household waste Please recycle where facilities exist The product complies with Safety Standards EN60335 2 30...

Page 2: ...ilarly qualified persons in order to avoid a hazard 9 DO NOT use the heater to ignite materials 10 This heater must only be used for the heating of people outdoors or indoors in an unenclosed space The heater is not to be used by children or persons with reduced physical sensory or mental capabilities or lack of experience or knowledge regardless of whether they have been given instruction or are ...

Page 3: ...t install AUSWAY PACIFIC PTY LTD shall not be liable for any loss damage or injury caused or resulting from inadequate fitting or incorrect placement of heaters close to water sources ELECTRICAL INFORMATION Installation must only be carried out by competent persons or a qualified electrician according to national regulations Any plug sockets and switches intended for use outdoors must have water i...

Page 4: ...be located in a position to allow proper and efficient use but one that ensures hot parts are not touched The recommended installation height of the RAINBOW is 2 4m to 3 5m 95 138 from the floor IMPORTANT DO not mount RAINBOW below 2 4m if any kind of automated on off controller is to be used Under no circumstances is the RAINBOW to be installed at less than 1 8m 71 from the floor Consideration sh...

Page 5: ...INSTALLATION Diagram 2 Correct Wall Ceiling Position ...

Page 6: ... install pointing directly downwards The identification mark and model reference should be visible after installation The RAINBOW must not be attached facing or close to any combustible material eg wood or PVC cladding fascia or soffit or other materials that could blow onto the heater The fixed wiring insulation coming into contact with parts with a temperature rise of greater than 50 C must be p...

Page 7: ...advisable to warm the heater for 10 20 minutes to dry the unit and prevent staining The lamp used in the Herschel Rainbow is Ultra long life 10 000 hours Changing the lamp should only be carried out by suitably qualified personnel using the instructions available on Herschel s website TROUBLESHOOTING E1 Error on Display Control unit overheat Check installation clearances Let heater cool for 15 min...