background image

WIRELESS

TROUBLE-SHOOTING

Page 9

NO SIGNAL FROM ANY TRANSMITTER

(Instrument recognizes the receiver, but the receiver does not recognize the sensor(s).)

SYMPTOM:

REMEDY:

-Maestro needle points to 0 MPH, the North LED is illuminated.

-Test the batteries in each external SENSOR/TRANSMITTER

and replace if necessary.

-Put the TRANSMITTER(S) into TEST MODE by pressing TEST

BUTTON in the battery compartment of TRANSMITTER.

-Remove the RECEIVER from the wall and confirm receipt of

TRANSMISSION(S) based on the color of the flashing light.

MINI-MAX

100

0

20

miles per hour

km/h

10

30

50

70

40

60

80

90

60

40

10

0

80

100

120

140

160

MAESTRO

Celcius

Fahrenheit

40

30

20

10

0

-10

-20

-30

50

60

70

80

90

10

11

12

10

0

-10

-20

20

30

40

-30

RECEIVER

INDICATOR

ORANGE

RED

GREEN

TRANSMITTER

RED

GREEN

ORANGE

....................WIND

................RAIN

.........TEMPERATURE

-If the instrument continues to display the error code, call Maximum

for further assistance.

Note: Depending on the origin of the problem, error

codes may not display on all instruments.

30 Barnet Boulevard

New Bedford, MA 02745

(508) 995-2200

-Mini-Max needle points to 32 F (or 0 C)

Summary of Contents for Mini-Max

Page 1: ...om the RECEIVER to TERMINAL 1 and the wire from the RECEIVER to TERMINAL 2 on the rear of the MINI MAX meter BLACK RED GREEN WHITE 2 1 OUT GND IN 5 4 3 WHITE GREEN RED MINI MAX RECEIVER 12 VOLT POWER...

Page 2: ...ver and the temperature transmitter NOTE If more than 15 minutes has passed since the button on the temperature transmitter was pushed it will need to be pushed again The light on the receiver will bl...

Page 3: ...f more than 15 minutes has passed since the test button on the temperature transmitter was pushed it will need to be pushed again If the signal has been lost move the transmitter to an alternate mount...

Page 4: ...hat is also used to route power to the instrument For the cleanest installation we recommend making a hole in the wall large enough to insert the wireless receiver We also recommend mounting the brass...

Page 5: ...the recorded high temperature since the last reset NOTE Before reading your thermometer you should lightly tap the case with your finger A tap change of 1 2 degrees is a common occurrence with any sl...

Page 6: ...POWER SUPPLY to the same MINI MAX power terminals no polarity On the MINI MAX connect the wire from the RECEIVER to TERMINAL 1 IN and the BLACK wire from the RECEIVER to TERMINAL 2 COM Connect the tw...

Page 7: ...no polarity On the MINI MAX connect the wire from the RECEIVER to TERMINAL 1 IN and the BLACK wire from the RECEIVER to TERMINAL 2 COM Connect the MINI MAX and MAESTRO instruments using the supplied g...

Page 8: ...20 2 0 30 4 0 3 0 FLASHING LED s MINI MAX MAESTRO SYMPTOM REMEDY The pointer is in the 3 o clock position The central LED s are flashing The Maestro primary direction LED s are illuminated Check all w...

Page 9: ...irm receipt of TRANSMISSION S based on the color of the flashing light MINI MAX 1 0 0 0 2 0 miles per hour km h 1 0 30 50 7 0 40 60 80 9 0 60 4 0 1 0 0 80 1 0 0 1 2 0 1 4 0 1 6 0 MAESTRO Celcius Fahre...

Page 10: ...in the battery compartment of TRANSMITTER This should cause the LED on the receiver to flash every 2 seconds If the instrument continues to display the error code call Maximum for further assistance...

Page 11: ...TRANSMITTER This should cause the LED on the receiver to flash GREEN every 4 seconds If the instrument continues to display the error code call Maximum for further assistance 1 0 0 0 2 0 miles per ho...

Page 12: ...receiver to make sure it is blinking ORANGE every 4 seconds Check the instruments to see if the error has been corrected Unlike the WIND and TEMPERATURE TRANSMITTERS the RAIN TRANSMITTER will not aut...