m a x A I 4 3 0 i v T E C H N I C A L M A N U A L
39
Rev C 6/17/2020
Force Regen Key.
Force Regen OFF
Force Regen ON
Once the
Regen Mode Manual
is
active then the Force Regen key will be available.
The
Force Regen Key
will work as a push button that will allow the operator to perform the regen cycle.
Default status will be OFF, once the Force Regen is pressed the cluster will send to ECM the
SPN 3696
as
active
for one second and then the cluster will automatically switch the
SPN 3696
as
not
active
and
changing the switch state back to default status OFF. Every time the
Force Regen Key
is pressed
the
message “Initiate Regen” momentarily in the banner on the top of the screen
Back Key.
Press the
Back Key
to return to the
Instrument Setup
sub menu.