11
5. MAINTENANCE INSTRUCTIONS
A periodic check (at least once a year) of the appliance contributes to extending its service life and assures
proper operation.
Any maintenance operation on the appliance must only be done by highly qualified personnel trained in
the operations being performed and authorised. Operations must be carried out in accordance with the
safety regulations in force in the country where the appliance is installed, pursuant to the regulations
relative to plants and to workplace safety.
Before carrying out any maintenance on the appliance it must be disconnected from the mains and allowed
to cool down.
The Manufacturer is not responsible for any appliance faults caused by defective maintenance.
5.1 Access to the components for inspection
Removing the back;
-
Tangential motor (on the back)
-
Circular resistors
-
Radial motors
-
Humidification solenoid valve
-
Humidification piping/fittings unit
Removing the right side:
-
Door microswich
-
Control thermostat bulb
-
Contactors
-
Power supply terminal board
-
Hood terminal board
-
Safety thermostat
-
Capacitors
-
LED power supply
-
Cam programmer (Motor reversing gear)
-
9-way electrical wiring connector for controls (on door)
Removing the control protection box (on door):
-
Timer ("End of cooking")
-
Regulation thermostat
-
Automatic humidifier
-
Warning lights
-
LED Bar
5.2 Safety thermal devices
The appliance is equipped with a (manually reset) safety thermostat, to protect against excessive and
hazardous overheating which might accidentally occur inside it. If the safety thermostat is activated, the
power supply to the appliance is cut off.
The safety thermostat is located inside of the appliance.
Important
Safety thermostat should only be reactivated after eliminating the anomaly that caused them to trip.
This
can only be done by a Service technician.
5.3 Replacing the cooking chamber gasket
The cooking chamber gasket has a rigid profile with retaining fins. This profile must be inserted in
the suitable perimeter seat on the “front” of the chamber.
To replace the gasket, simply remove the used one from its seat (pull tightly near the 4 corners)
and, after cleaning any impurities from the seat, insert the new gasket (to facilitate the assembly,
it is recommended to wet the profile of the gasket with soapy water).