16. Place a J26 shunt and repeat the performance of the V
REF
/2 reading.
17. Apply a 10kHz sine wave from an external source, e.g. Audio Precision 2700, to CON3
(AIN0+). Synchronize the external source with the MAXREFDES74# ADC by connecting
CON9 (SYNC_CLK_OUT) to the REF IN input for coherent sampling. In the ADC
Configuration tab, check the Sync-Out CLK (10MHz) selection box to enable the 10MHz
clock output from the ZedBoard and click the Set button. Then go to the FFT tab, select
Sampling Rate, Number of Samples, put desired signal frequency in the Input Signal
(Hz) pulldown menu and then click the Calculate button. The GUI will calculate the
coherent input signal frequency based on the coherent sampling equation. The user will
then enter the adjusted signal frequency, shown in the Adjusted (Hz) box, into the
external function generator. Then click the Capture button in the FFT tab.
Figure 8. Coherent sampling of a 10kHz sine wave.
Figure 9. Coherent sampling of a 1kHz sine wave.