![Maxim Integrated MAX32660 User Manual Download Page 45](http://html1.mh-extra.com/html/maxim-integrated/max32660/max32660_user-manual_1744484045.webp)
MAX32660 User Guide
Maxim Integrated
Page 45 of 195
4.12.1
System Initialization Register Details
Table 4-27: Function Control Register 0
System Initialization Status Register
SIR_STAT
[0x0000]
Bits
Name
Access
Reset
Description
31:2
-
RO
-
Reserved for Future Use
Do not modify this field.
1
cfg_err
RO
See
Description
Configuration Error Flag
This field is set by hardware during reset if an error in the device configuration is
detected.
0: Configuration valid.
1: Configuration invalid.
Note: If this field reads 1 a device error has occurred. Please contact Maxim
Integrated technical support for additional assistance providing the address
contained in
.addr.
0
cfg_valid
RO
See
Description
Configuration Valid Flag
This field is set to 1 by hardware during reset if the device configuration is valid.
0: Configuration Invalid
1: Configuration Valid
Note: If this field reads 0 the device configuration is invalid and a device error has
occurred. Please contact Maxim Integrated technical support for additional
assistance.
Table 4-28: System Initialization Address Error Register
System Initialization Status Register
SIR_ADDR_ER
[0x0000]
Bits
Name
Access
Reset
Description
31:0
addr
RO
0
Configuration Error Address
If the
.cfg_err
field is set to 1, the value in this register is the address of the
configuration failure.
4.13
Function Control Registers
The FCR base peripheral address is 0x4000 0800. Refer to
Table 3-1: APB Peripheral Base Address Map
all APB mapped peripherals.
Table 4-29: Function Control Registers, Offsets and Descriptions
Offset
Register Name
Access
Description
[0x0000]
R/W
Function Control Register 0
4.13.1
Function Control Register Details
Table 4-30: Function Control Register 0
Function Control Register 0
FCR_REG0
[0x0000]
Bits
Name
Access
Reset Description
31:24
-
RO
0
Reserved for Future Use
Do not modify this field.