MAX32560 EMV DTE User’s Manual
PCD_DTE_MAX32560_V3. 09/01/2017
CONFIDENTIAL
│
Maxim Integrated | 12
Analogue Test Menu
The Analogue Test Menu shown in Figure 9 provides convenience functions for use by the EMV
Analogue Test Engineer to send specific commands. It also provides loopback functionality if desired,
both one with a settable number of loops, and one that will loop continuously until a key is pressed to
exit the loop.
NOTE:
Per PCD_L1_Device_Test_Environment_v25a_161115 all menu options other than 1, require the
Carrier be enable first. The Carrier status is shown at the top of the Analogue Menu.
Figure 9: DTE Analogue Menu
All Analogue commands other than
C. Continuous Polling
, will be executed in a loop the number of times
specified by the Loop Setting. This defaults to 1 at boot, and may be changed in the
L. Change Loop
Settings
menu. Only numbers from 1-9999 will be accepted. The current setting for number of loops is
shown at the top of the Analogue Menu.