2.3 Basic Connection Setup
Figure 1 shows the basic connections of the 78M6613 Evaluation Board for use with external equipment.
The 78M6613 Evaluation Board is powered through the USB cable. This same USB cable provides the
communications link between the host PC and the 78M6613 Evaluation Board.
The 78M6613 Evaluation Board accepts 120 VAC and 230 VAC (nominal) up to 300 VAC (max).
Figure 1: 78M6613 Evaluation Board Connections
Attach an AC source to J3 (Neutral) and J6 (Line). Attach the AC load to J4 (Neutral) and J8 (Line).
Note: The hardware and embedded firmware are capable of measuring two outlets or AC loads. For more
information, contact Maxim application support.
Connect the USB
Port to the Host PC
Neutral
Neutral
Line
Line
Connect to
the Load to
be Measured
Connect to AC
wall outlet