MAXDATA PLATINUM 1600 IR Quick Start Manual Download Page 4

Remove the plastic air baffle.

Press the green latch at the rear of the power supply and pull the power supply from 

the chassis.

Install the hard disk drive.

Insert the replacement power supply module into the power supply cage until it clicks 
into place.

Install the carrier assembly.

Hard drives are numbered from bottom to top and from left to right in ascending order.

Installing Hard Drives

Replacing the Hotswap Power Supply

Caution
Any empty drive bays must be occupied by carriers with baffles to maintain proper system 
cooling.
To avoid possible damage to your chassis, use only carriers that came with your server system.

Note
The carrier lever must be held in the FULLY OPEN position to install it into the chassis. Slide the 
carrier into the chassis until it stops, then rotate the lever until it snaps shut.

Hard Drive Numbering

4

  MAXDATA PLATINUM 1600 IR M3 – Quick Start Guide 

Baffle

Drive Carrier

Attach with 
four screws

Remove the PCI riser assembly.

Remove the filler panel from the add-in card slot and remove the screw (A).

Insert the add-in card until it seats in the riser connector (B).

Secure the add-in card with the screw you removed in step 2 (C).

Install the PCI riser assembly into the server system.

Installing a PCI Addin Card