Remove the plastic air baffle.
Press the green latch at the rear of the power supply and pull the power supply from
the chassis.
Install the hard disk drive.
Insert the replacement power supply module into the power supply cage until it clicks
into place.
Install the carrier assembly.
Hard drives are numbered from bottom to top and from left to right in ascending order.
Installing Hard Drives
Replacing the Hotswap Power Supply
Caution
Any empty drive bays must be occupied by carriers with baffles to maintain proper system
cooling.
To avoid possible damage to your chassis, use only carriers that came with your server system.
Note
The carrier lever must be held in the FULLY OPEN position to install it into the chassis. Slide the
carrier into the chassis until it stops, then rotate the lever until it snaps shut.
Hard Drive Numbering
4
MAXDATA PLATINUM 1600 IR M3 – Quick Start Guide
Baffle
Drive Carrier
Attach with
four screws
Remove the PCI riser assembly.
Remove the filler panel from the add-in card slot and remove the screw (A).
Insert the add-in card until it seats in the riser connector (B).
Secure the add-in card with the screw you removed in step 2 (C).
Install the PCI riser assembly into the server system.
Installing a PCI Addin Card