--15--
Belinea Technical Service Manual
TABLE 1-3:
AC CHARACTERISTICS
Parameter
Symbol
Vcc= 2.5-5.5V
Vcc= 4.5 - 5.5V
Units
Remarks
Min
Max
Min
Max
Clock frequency
F
CLK
0
100
0
400
kHz
Clock high time
T
HIGH
4000
—
600
—
ns
Clock low time
T
LOW
4700
—
1300
—
ns
SDA and SCL rise time
T
R
—
1000
—
300
ns
(Note 1)
SDA and SCL fall time
T
F
—
300
—
300
ns
(Note 1)
START condition hold time
T
HD
:
STA
4000
—
600
—
ns
After this period the first clock
pulse is generated
START condition setup time
T
SU
:
STA
4700
—
600
—
ns
Only relevant for repeated
START condition
Data input hold time
T
HD
:
DAT
0
—
0
—
ns
(Note 2)
Data input setup time
T
SU
:
DAT
250
—
100
—
ns
STOP condition setup time
T
SU
:
STO
4000
—
600
—
ns
Output valid from clock
T
AA
—
3500
—
900
ns
(Note 2)
Bus free time
T
BUF
4700
—
1300
—
ns
Time the bus must be free
before a new transmission can
start
Output fall time from V
IH
minimum to V
IL
maximum
T
OF
—
250
20 + 0.1
C
B
250
ns
(Note 1), C
B
≤
100 pF
Input filter spike suppression
(SDA and SCL pins)
T
SP
—
100
—
50
ns
(Note 3)
Write cycle time
T
WR
—
10
—
10
ms
Byte or Page mode
Transmit-Only Mode Parameters
Output valid from VCLK
T
VAA
—
2000
—
1000
ns
VCLK high time
T
VHIGH
4000
—
600
—
ns
VCLK low time
T
VLOW
4700
—
1300
—
ns
VCLK setup time
T
VHST
0
—
0
—
ns
VCLK hold time
T
SPVL
4000
—
600
—
ns
Mode transition time
T
VHZ
—
500
—
500
ns
Transmit-Only power up time
T
VPU
0
—
0
—
ns
Input filter spike suppression
(VCLK pin)
T
SPV
—
100
—
100
ns
Endurance
—
10M
—
10M
—
cycles
25
°
C, V
CC
= 5.0V, Block Mode
(Note 4)
Note 1: Not 100% tested. C
B
= total capacitance of one bus line in pF.
2: As a transmitter, the device must provide an internal minimum delay time to bridge the undefined region (min-
imum 300 ns) of the falling edge of SCL to avoid unintended generation of START or STOP conditions.
3: The combined T
SP
and V
HYS
specifications are due to Schmitt trigger inputs which provide noise and spike
suppression. This eliminates the need for a T
I
specification for standard operation.
4: This parameter is not tested but guaranteed by characterization. For endurance estimates in a specific appli-
cation, please consult the Total Endurance Model which can be obtained on our BBS or website.