Tidland Digital Measurement System 

MI 659995 1 M 

 

2-1 

OPERATION 

Step One 

1.  Remove the Digital Measurement System (DMS) from the shipping package. 
2.  Remove the two small end cover plates located on the back side of the cable 

management to gain access to the mounting blocks. 

3.  Loosen—do not remove—the two button head screws that retain the mounting blocks to 

the backing plate. 

4.

 

Lift the DMS into place.  (Note:  The end stops may need to be removed to access the 
button head screws on the front of the unit.) 

 

Step Two 

1.

 

Consult your customer drawing for mounting dimensions (Fig. 1).  

2.

 

Transfer punch two holes on your side frame for each end of the DMS block mount 
assembly (Fig 2). 

 

 

Fig. 1 

Fig. 2 

 
2.  Drill and tap the four holes 1/2-13 NC. 
3.  Install two 1/2-13 NC socket head cap screws through the mounting blocks at each end 

to secure the unit to your side frames. 

4.  Tighten the four button head cap screws to fully secure the end blocks  

to the backing plate. 

 
Step Three 

1.  Plug transformer into 110V wall outlet.  
2.  Connect green ground wire to earth ground. 

 
Step Four 

1.  The DMS requires clean, non-lubricated (instrument quality) air at approximately  

5.5 bar [80 psi]. 

2.  Connect hose assembly to mill air.  

Note: 1/8 NPT connection is provided. 

Summary of Contents for TIDLAND

Page 1: ...Tidland Digital Measurement System Installation Operation and Maintenance EN For use with SIKO MA503 display MI 659995 1 M TIDLAND SLITTING SOLUTIONS...

Page 2: ......

Page 3: ...ON 2 1 OPERATION 3 2 Positioning anvil rings using the DMS 3 2 MAINTENANCE 4 1 Cleaning the linear rails 4 1 PARAMETERS 5 1 Display Parameters 5 1 Parameter Description 5 2 CAUTION Wear eye protection...

Page 4: ...www maxcessintl com Tidland Digital Measurement System MI 659995 1 M 1 1 WIRING DIAGRAM Wiring Diagram...

Page 5: ...t Step Two 1 Consult your customer drawing for mounting dimensions Fig 1 2 Transfer punch two holes on your side frame for each end of the DMS block mount assembly Fig 2 Fig 1 Fig 2 2 Drill and tap th...

Page 6: ...gnated datum location push to reset the display to the reference value normally zero 2 Press and hold the brake release button on the reader head and move the reader head to the desired position The d...

Page 7: ...clear of debris and dust buildup Always wear eye protection and dust mask when using a vacuum system or compressed air Do not use solvents on the rails Solvents will remove the protective lubrication...

Page 8: ...switch Auto on oFF oFF 8 Switch off time in hours0 only for switch off methods on PEriod 0 2 0 5 1 0 2 0 4 0 8 0 0 2 9 Storage rSto on oFF oFF 10 Delayed switch 4_oFF on oFF on 11 Delayed reset functi...

Page 9: ...before Determination of the decimal point according to the resolution Ref Reference value Absolute reference point of the measuring system This value is set by referencing the system according to chap...

Page 10: ...alue via key on front of the display oFF Reset function off on Reset function on F_rEL Access incremental measurement to switch from absolute dimension and zero setting to subsequent relative dimensio...

Page 11: ......

Page 12: ...s maxcess eu www maxcess eu CHINA Tel 86 756 881 9398 Fax 86 756 881 9393 info maxcessintl com cn www maxcessintl com cn INDIA Tel 91 22 27602633 Fax 91 22 27602634 india maxcessintl com www maxcess i...

Reviews: