www.maxcessintl.com
Tidland Digital Measurement System
MI 659995 1 M
2-1
OPERATION
Step One
1. Remove the Digital Measurement System (DMS) from the shipping package.
2. Remove the two small end cover plates located on the back side of the cable
management to gain access to the mounting blocks.
3. Loosen—do not remove—the two button head screws that retain the mounting blocks to
the backing plate.
4.
Lift the DMS into place. (Note: The end stops may need to be removed to access the
button head screws on the front of the unit.)
Step Two
1.
Consult your customer drawing for mounting dimensions (Fig. 1).
2.
Transfer punch two holes on your side frame for each end of the DMS block mount
assembly (Fig 2).
Fig. 1
Fig. 2
2. Drill and tap the four holes 1/2-13 NC.
3. Install two 1/2-13 NC socket head cap screws through the mounting blocks at each end
to secure the unit to your side frames.
4. Tighten the four button head cap screws to fully secure the end blocks
to the backing plate.
Step Three
1. Plug transformer into 110V wall outlet.
2. Connect green ground wire to earth ground.
Step Four
1. The DMS requires clean, non-lubricated (instrument quality) air at approximately
5.5 bar [80 psi].
2. Connect hose assembly to mill air.
Note: 1/8 NPT connection is provided.